ADLER EUROPE AD 7861 Compressor Air Dehumidifier User Manual
- June 13, 2024
- ADLER EUROPE
Table of Contents
ADLER EUROPE AD 7861 Compressor Air Dehumidifier
- DO NOT COVER INSCRIPTION IMPORTANCE The inscription on the device means that the device is not to be covered which could cause blankets and other textile products which could cause.
SAFETY CONDITIONS
IMPORTANT INSTRUCTIONS ON SAFETY OF USE PLEASE READ CAREFULLY AND KEEP FOR FUTURE REFERENCE
- Before using the device, read the operating manual and follow the instructions contained in it. The manufacturer is not liable for damages caused by using the device contrary to its intended purpose or improper operation.
- The device is for home use only. Do not use for other purposes that are not for its intended purpose.
- The device should only be connected to an AC outlet with a grounded 220 240V ~ 50Hz. To increase operational safety, multiple electrical devices should not be connected to one current circuit at the same time.
- Use extreme caution when using the device when children are nearby. Do not allow children to play with the device, do not allow children or people unfamiliar with the device to use it.
- WARNING: This equipment may be used by children over 8 years of age and people with limited physical, sensory or mental ability, or people who have no experience or knowledge of the equipment, if this is done under the supervision of a person responsible for their safety or have been granted them information on the safe use of the device and are aware of the dangers of using it. Children should not play with the equipment. Cleaning and maintenance of the device should not be performed by children, unless they are over 8 years old and these activities are carried out under supervision.
- Always disconnect the power plug by holding the socket with your hand after use. DO NOT pull on the power cord.
- Do not immerse the cable, plug and the whole device in water or any other liquid. Do not expose the device to atmospheric conditions (rain, sun, etc.) or use in conditions of high humidity (bathrooms, damp mobile homes).
- Periodically check the condition of the power cord. If the power cord is damaged, it should be replaced by a specialist repair shop to avoid danger.
- Do not use the appliance with a damaged power cord or if it has been dropped or damaged in any other way or if it is not working properly. Do not repair the device yourself, as there is a risk of electric shock. Take the damaged device to an appropriate service center for checking or repair. All repairs may only be carried out by authorized service points. Incorrectly performed repairs can cause serious danger for the user.
- Place the device on a cool, stable surface, away from hot kitchen appliances such as: electric stove, gas burner, etc.
- Make sure that nothing is blocking the air inlet and outlet of the device
- Use the device only on a level surface to prevent the condensation from spilling out
- To provide additional protection, it is advisable to install a residual current device (RCD) in the electric circuit with a rated residual current not exceeding 30mA. Ask an electrician for this.
- Clean the air filter regularly. The frequency of cleaning depends on the cleanliness of the air.
- After turning off the machine, wait at least 5 minutes before turning it back on.
- For effective dehumidification, a gap of at least 20 cm should be used between the side walls of the devices and the compressed furniture or curtains.
- To avoid the risk of fire or explosion, do not spray the dryer
- To use the housing parts, do not place the dehumidifier near heating devices.
- Remove the water collected in the tank. Accidentally drinking water or using it with other people may cause illness.
- Does not support devices with the back cover removed due to moving and hot parts.
- Do not use any means to carry out the thawing or operating process other than those recommended by the manufacturer.
- The device should be available as part of a permanent list of ignition sources, i.e. without open flame, without a working gas device or without a working device heater.
- Do not pierce or smoke.
- Please note that refrigeration manufacturers may not contain fragrance.
Before first use
- The dehumidifier must be used on a level and stable surface, keep distances between unit and other objects according to picture 1 to ensure suitable efficiency. Close all windows and doors of room you want to dehumidify the air.
- To prevent the water from freezing, do not use the dehumidifier and the drain hose at ambient temperature below 0°C
- Do not use the dehumidifier outside. Exposure to direct sunlight or rain may result in overheating, electric shock and fire.
- Do not put water tank on the dehumidifier to avoid any spill of water into the unit inside and deteriorates the insulation.
- Never attempt to use the dehumidifier for special uses, such as food dehumidification or preservation of art objects, or the like.
- Do not use the dehumidifier where any leakage of oil or flammable gas may take place. Do not use the unit in places subject to chemicals.
- For continuous draining, make sure that the drain hose is set properly with slope.
- Be careful that a heating appliance is not exposed to the wind from the dehumidifier.
- Do not use the dehumidifier as a chair or a footstool.
- Do not remove the float lever from the water tank.
- Do not block up the air intakes and the air outlets.
- Do not cover the unit with washed clothes.
- Prior to continuous operation for a long duration, periodical checking is required especially for the air clean filter, the drain hose, or the like.
- The device shall be installed, operated and stored in a room with a floor area larger than 4 square meters and in a room with a wellventilated area.
- Never put your fingers, rods, into the air outlet and inlet.
Product description
Product description: AD7861 Air dehumidifier (picture 2)
- Handle for easy carry
- Air outlet
- Back housing
- Control panel
- Air inlet
- Front housing
- Water tank 2.0L
- Power cord
- Foot
- Drain hose
- Float laver
- Net air filter
- Filter grid
- Continuous water drainage port
control panel
- A. Power button
- B. Desired humidity decrease button
- C. Desired humidity increase button
- D. Timer 0-24 hours button
- E. Timer indicator
- F. self-defrost indicator
- G. Compressor activity indicator
- H. Full water tank indicator
- J. Digital “88” indicator
The digital “88” indicator (J) will show:
- selected desired humidity level in range: 30-90 percent of relative humidity (RH)
- hours in range: 1-24, when you program delayed start or delayed stop
- “LO” – means low, when the environment humidity is lower than 35%
- “HI” – means high, when the environment humidity is higher than 95%,
USAGE
- Plug in the device.
- Press the power button (A) to start operation, the digital “88” indicator (J) will be lighted on. Press the power button (A) again to stop operation.
- Press the bottom (C) or (D) to set the desired humidity level in the room, which can be set from 30% to 90% at 5% intervals or “CO”.
After a period of working
- when environment humidity is lower than the selected humidity by 2%, compressor will stop,
- when environment humidity is equal to or higher than the selected humidity by 3%, the compressor will restart once 3-minute compressor protection time over.
TIMER FUNCTION
- Press the timer button (D) is the program the time:
- when the device is turned on to set up the delayed stop function:
- Repeatedly pressing of the timer button (D) adjust desired time, it will be circulate from 0-1-2……23-24. The time indicator (E ) will be lighted on. The device will stop operation when desired time passed.
- when the device is turned off to set up the delayed start function:
- Repeatedly pressing of the timer button (D) adjust desired time, it will be circulate from 0-1-2……23-24. The time indicator (E ) will be lighted on. The device will start operation when desired time passed.
- To cancel the timer programming, press the timer button (D) to zero.
- The programmed time remains unchanged if the machine stops to work due to full water tank or during self-defrosting.
WATER TANK DRAINAGE
- When the water tank (7) is full, the indicator (H) light up, the operation will stop automatically and the buzzer will beep 15 times to alert the user, that the water need to be emptied from the water tank (7). Look at pictures 4 and 5. The water drainage procedure is:
- Lightly press on the sides of the tank (7) with both hands and pull the tank out gently.
- Pour out the collected water. If the water tank (7) is dirty, wash it with cold or lukewarm water.
- REMARK: Do not remove the float laver (11) from the water tank (7). The built-in full water sensor will no longer be able to detect the water level correctly without the float laver (11) and the device will stop operation.
- When putting back the water tank (7), press the tank firmly into place with both hands. If the tank is not positioned properly, the built-in full water sensor will be not activated, so the dehumidifier will not operate.
CONTINUOUS WATER DRAINAGE FUNCTION
When setting the humidity level to “CO” on digital display (J), the compressor will run continuously. The user can: 6.a. connect the drain hose (10) If the user connects the drain hose (10), the water will drain out continuously to sink / bathtub or other outside container you will set up. The device features a continuous water drainage port (14) – look at picture 3. It is need to take out the water tank (7) to assemble the drain hose (10) to the continuous water drainage port (14). The drain hose (10) (with an inner diameter of 10mm) should be put on the port (14) drain hole shown at picture 3. The water can be continuously drained out from the port (14). 6.b. do not connect the drain hose (10). If the user doesn’t connect the drain hose (10), the water will drain to the water tank (7). When the water tank (7) be full, the device will stop operation automatically.
AUTO DEFROST FUNCTION
When frost builds up on the built-in evaporator coil, the compressor will cycle off and the device will go in to self-defrost mode automatically. Following completion of the defrost mode, the device will return to the previously operating settings. When the device is running in a room with a temperature between 5 degree of Celsius and 12 degree of Celsius, it will enter self-defrost mode roughly every 30 minutes. When the device is running in a room with a temperature between 12 degree of Celsius and 20 degree of Celsius, it will enter the self-defrost mode roughly every 45 minutes.
Cleaning and Maintenance
- Turn off the unit and disconnect the power plug before starting any cleaning or other routine maintenance.
- To avoid the risk of electric shock, never sprinkle or spill water on the dehumidifier when cleaning.
- Turn off the device and empty the water out of the water tank before moving the device. Be sure to hold by the handle while moving.
- Wipe up the housing of the device with wet cloth.
- Don’t dismantle the floater (11) from the water tank (7). To clean the water tank (7) do not use detergent, scouring pads, chemically treated dust cloths, gasoline, benzene, thinner, or other solvents, as these can scratch and damage the tank and cause water leakage.
- Prior to planned continuous operation for a long duration, periodical checking is required especially for the net air filter (12) and the drain hose (10).
- To clean or replace the filters should be:
- disconnect the plug and take out the water tank (7),
- remove the grid (13) as shown at picture 6,
- remove the net air filter (12) gently from the filter grid (13),
- clean filter every two weeks with a vacuum cleaner. Run a vacuum cleaner lightly over the surface of the air filter (12) to remove dirt. If the air filter (12) is exceptionally dirty, wash it with warm water and a mild cleanser and dry thoroughly. Dehumidification performance may decrease when the filter is clogged with debris.
- put the filter inside the filter grid and assemble them back into the device housing.
- Don’t clean the device with gasoline, thinner or liquid detergent.
- Storage: when the device is not being used for a long period of time and you want to store it note the following steps:
- Empty any water left in the water tank.
- Fold up the power supply cord (8) and put it inside the water tank (7) inside.
- Clean the net air filter (12).
- Storage in a cool and dry place.
TROUBLE SHOOTING
- If a condition listed below occurs, please check the following items before calling customer service.
- Problem 1: The device does not operate.
- Possible reason 1: Has the power cord been disconnected?
- Solution of problem: Plug the power cord into the outlet.
- Possible reason 2: Is the full water tank indicator (H) blinking?
- Solution of problem: The tank is full or in a wrong position. Empty the water tank (7) and then re-position the tank.
- Possible reason 3: Is the temperature of the room above 35 degree of Celsius or below 5 degree of Celsius?
- Solution of problem: Built-in protection device is activated and the dehumidifier cannot be started in the temperature of the room above 35 degree of Celsius or below 5 degree of Celsius.
- Problem 2: The dehumidifying function does not work
- Possible reason 1: Is the net air filter (12) clogged?
- Solution problem 1: Clean the air filter as instructed under “Cleaning and Maintenance” – point 7.
- Possible reason 2: Is the air inlet (5) or the air outlet (2) obstructed?
- Solution of problem: Remove the obstruction.
- Problem 3: No air is discharged.
- Possible reason 1: Is the net air filter (12) clogged?
- Solution of problem: Clean the air filter as instructed under “Cleaning and Maintenance” – point 7.
- Problem 4: Operation is noisy
- Possible reason 1: Is the device tilted or unsteady positioned?
- Solution of problem: Move the device to a stable, even, sturdy surface.
- Possible reason 2: Is the net air filter (12) clogged?
- Solution of problem: Clean the air filter as instructed under “Cleaning and Maintenance” – point 7.
- Problem 5: E1 Code shown on the digital indicator (J)
- Possible reason 1: Coil sensor short circuit or open circuit
- Solution of problem: Contact the seller who issued you purchase bill.
TECHNICAL DATE
- Dehumidify capacity at 30°C / 80% RH): 10 liters / 24 hours
- Noise level: <= 42dB(A)
- Water tank capacity: 2.0 liters
- Airflow: 150m3/hour
- R290 coolant weight: 45 grams
- Rated Input Power: 280W
- Power supply: 220-240V ~50Hz
Caution, risk of fire.
- Do NOT pierce or burn.
- Be aware that the refrigerant may not contain an odor.
- Device shall be installed, operated and stored in a room with a floor area larger than 4 m.².
- The maximum refrigerant charge amount: 45g.
Please transfer cardboard packaging to waste paper. Pour the polyethylene bags (PE) into the plastic container Worn device should be returned to the appropriate point storage because it is dangerous in the device ingredients may pose a threat to the environment. The electrical device should be handed over to limit its reuse and use. If in the device there are batteries you have to take out and give to the point stored separately.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>