K RCHER BP 4.500 Garden Pump User Manual

October 31, 2023
K RCHER

**K RCHER BP 4.500 Garden Pump User Manual

**

General notes
Read these original operating instructions and the enclosed safety instructions before using the device for\ the first time. Proceed accordingly. Keep both books for future reference or for future owners.

Intended use
Please observe the requirements of EN 1717 when connecting this product to the drinking water network and contact your sanitation specialists if you have any questions.This device has been developed for private use and is  not intended for the load imposed by commercial use.The device is primarily intended for use in the garden and provides constant pressure for garden watering. When connecting sprinklers, a maximum of the follow ing areas can be irrigated:

  • BP 4.500 Garden: 400 m2
  • BP 5.000 Garden: 5 50 m2
  • BP 6.000 Garden: 900 m2
  • BP 7.000 Garden: 1000 m2

CAUTION
Risk of injury!
Risk of injury from toxic substances.
Do not drink water that has been pumped by the pump!

Permissible feed fluids

Permissible feed fluids:

  • Processed water
  • Well water
  • Spring water
  • Rain water
  • Swimming pool water with intended dosage of additives

The temperature of the delivered liquid must not exceed 35 °C.

Improper use

Note
The manufacturer accepts no liability for possible damage caused by improper use or incorrect operation.

Hazard levels

  • **DANGER**

  • Indication of an imminent threat of danger that will lead to severe injuries or even death.
    WARNING

  • Indication of a potentially dangerous situation that may lead to severe injuries or even death.
    CAUTION

  • Indication of a potentially dangerous situation that may lead to minor injuries.
    ATTENTION

  • Indication of a potentially dangerous situation that may lead to damage to property.

Environmental protection

The packing materials can be recycled. Please Ndispose of packaging in accordance with the environmental regulations.
Electrical and electronic devices contain valuable, recyclable materials and often components such as batteries, rechargeable batteries or oil, which – if handled or disposed of incorrectly – can pose a potential danger to human health and the environment. However, these components are required for
the correct operation of the device. Devices marked bythis symbol are not allowed to be disposed of together with the household rubbish

Notes on the content materials (REACH)
Current information on content materials can be found  at: www.kaercher.de/REACH

Accessories and spare parts
Only use original accessories and original spare parts.They ensure that the appliance will run fault-free and safely. Information  on accessories and spare parts can be
found at www.kaercher.com

Scope of delivery
The scope of delivery for the appliance is shown on the packaging. Check the contents for completeness when unpacking. If any accessories are missing or in the event of any shipping damage, please notify your dealer.

Warranty
The warranty conditions issued by our sales companyresponsible apply in all countries. We shall remedy possible malfunctions on your device within the warranty period free of cost, provided that a material or manufacturing defect is the cause. In a warranty case, please contact your dealer (with the purchase receipt) or the next authorised customer service site. (See overleaf for the address

Description of the device
The maximum amount of equipment is described in these operating instructions. Depending on the model used, there are differences in the scope of delivery (see packaging).

For the illustrations, refer to the graphics page

Illustration A
Illustration

  1. Cap, 2-way connection adapter
  2. way connection adapter for pumps G 1 (not included with BP 4.500 Garden)
  3. Connection adapter for pumps G 1 (included twice with BP 4.500 Garden)
  4. Sealing plug
  5. Connection G 1 (33.3 mm) suction line (inlet)
  6. Filling nozzle with cap
  7. Connection G 1 (33.3 mm) pressure line (outlet)
  8. ON/OFF switch
  9. Water drain valve
  10. Tap connection G 1
  11. Coupling with Aqua Stop
  12. Coupling
  13. Syringe
  14. Suction hose set incl. 3.5 m ready-to-connect, vacuum-proof spiral hose with suction filter and backflow stop
  15. Garden hose 1/2″ 20 m
  16. Power supply cable with plug

Only accessories included with Set and Set Plus.
Only accessories included with Set Plus.

Startup

We recommend using only original Kärcher suction hoses, filter components and hose connections. Using components from other manufacturers can lead to malfunctions when sucking the feed fluid, especially when\ using bayonet connection systems.

Before initial startup
Preparation

  • Remove the sealing plug.
  • Screw the connection adapter into the suction connection of the pump (inlet). Manually tighten.
  • Connect a vacuum-tight suction hose

Illustration B
Remove the sealing plug
Note

If the water is dirty, we recommend fitting a pre-filter (see Special accessories) between the check valve and the suction hose.

Illustration C
Assembly Instruction

Note
To shorten the re-suction time, use a suction hose with backflow stop. This prevents the suction hose from emptying after use (see Special accessories).

  • Screw the connection adapter into the pressure connection of the pump (outlet). Manually tighten.
    Illustration D
    Assembly Instruction

  • Open the filling nozzle cap.
    Illustration E
    Assembly Instruction

  • Fill the pump with water until it overflows.
    Illustration F
    Assembly Instruction

Operation

  1. Plug the mains plug into a mains socket.

  2. Switch the device on with the ON/OFF switch.’

  3. To shorten the suction time, raise the pressure hose approx. 1 m. Illustration I

  4. Wait until the pump simultaneously sucks and delivers.
    CAUTION
    Danger due to dry running
    Dry running damages the pump.
    Do not let the pump run dry!

  5. Do not leave the pump unattended during operation.
    ATTENTION
    Risk of injury. The system is pressurised! Risk of injury.
    (for pressure see chapter “Technical data”)

Ending operation

  1. Switch off the device at the ON/OFF switch.
  2. Pull the mains plug out of the socket.

Care and maintenance

DANGER
Danger of electric shock.
Always switch the device off and disconnect the mains  plug before working on the device.The device is maintenance-free.Rinse
Note
Rinse the pump with clear water after each use when cpumping water with additives

CAUTION
Risk of injury  Risk of injury from falling device.\When transporting the device, observe the weight of the device (see chapter Specifications) and secure it accordingly when transporting it in vehicles.

Manual transport

  1. Roll up the cable.
  2. Lift and carry the device by the carrying handle

Secure the device against slipping and tipping over.

CAUTION
Risk of injury
Risk of injury from falling device.When transporting the device, observe the weight of the device (see technical data) and secure it accordingly hen transporting it in vehicles.

Storage
CAUTION
Failure to observe the weight Risk of injury and damage Be aware of the weight of the device during storage.

  1. Store the device in a frost-protected place

Storing the device

  1. Depressurise the device by opening the water removal connected to the pressure side (e.g. opening the garden sprayer).

  2. Empty the hoses.

  3. Remove suction line and pressure line.

  4. Drain the pump via the water drain valve. Illustration H
    Assembly Instruction

  5. Store the device in a frost-protected place.

Special accessories
You will find the possible special accessories on the last page of these operating instructions

V_T• Fault Cause Rectification
Pump is running. but not delivering Air is in the pump. 1. Check for

correct startup (see chapter PIWEI(80011 and Operation).
Dirt particles block the suction area.| 1. Pull the mains plug out of the socket2. Clean the suction area.
The suction hose or the connection adapter is not cm:treaty screwed in.| 1. Check that the seals we fitted correctly
2.  Manually tighten the suction hose and con­nectico adapter.
The pre-filer is dogged.| 1.   Clean the pre-filter.
The pump does not start up. or stops suddenly during operation| The power supply is deconnected.| 1. Check the fuses and the ek<tncal connect bons.
The pump capacity drops or is too low| The suction area es clogged.| 1. Pull the mains plug out of the socket2. Clean the suction area.
The delivery rate of the pump depends on the dekvery head and the connected periphery.| 1. Observe the TU, delivery head (see chap-ter Speahcahons). select a different hose diameter or a different hose length if nec­essary.
The cross-section on the pressure side Is narrowed. e.g. due to the valvesbal tap not being fully open.| 1. Open the valve/ball tap completely.
The hose is lunked on the pressure ode.| 1.   Eliminate the kink pants in the hose.
The pre-flier 19 dogged.| 1.   Clean the pre-filtet.

  • BP 4.500
    Garden

  • BP 4.500 Garden Set

  • Plus
    BP 5.000 Garden

  • BP 5.000 Garden Set

  • Plus
    BP 6.000 Garden

  • BP 6.000 Garden Set

  • Plus
    BP 7.000 Garden

Mains voltage                                          V              230-240| 230-240| 230.240| 230-240
---|---|---|---
Power frequency                                      t i             50| so| | so| | so
Nominal power                                        W             550| 650| | 1000| | 1100
Maximum flow rate                                  vn            4500| 5000| | 6000| | 7030
Suction heigfil (max.)                                m             8| 8| | 8| | 8
Solids content in water                              kqim3       >2.5| >2.5| |

2.5| | >2.5
Pressure (max.)                                          MPa (bar) 0.36 (3.6)| 0.40| (4.0)| 0.45| (4.5)| 0.5 (5.0)
Delivery height (max.)                              m                    35| 40| | 45| | 50
Delivery temperature (max.)                                     35.0| 35.0| | 35.0| | 35.0
Parbcle sae (max.) of permissible feed flucts min           1| 1| | 1| | 1
Pump type                                                             Jet| Jet| | Jet| | Jet
| | | | |
Sound pressure level L. DA                                      013(A) 56| 58| | 69| | 68
Guaranteed sound power level LwA            dB(A)         It| 73| | 84| | 83
Dimensions and weights| | | | |
Weight (wtnout accessones)                       kg            6.4| 7.0| | 9.7| | 10.0

Note
Reason for exception according to regulation (EU) 2019/1781 Annex I Section 2 (12): (j) Subject to technical modifications!

Characteristic curves
Dimension
Dimension
Declaration of Conformity

EU Declaration of Conformity

We hereby declare that the machine described below  complies with the relevant basic safety and health requirements in the EU Directives, both in its basic designand construction as well as in the version placed in circulation by us. This declaration is invalidated by any changes made to the machine that are not approved by us.
Product: Pump
Type: 1.645-xxx
Currently applicable EU Directives
2006/42/EC (+2009/127/EC)
2014/30/EU
2000/14/EC
2011/65/EU
2009/125/EC
Commission Regulation(s)
(EU) 2019/1781
Harmonised standards used
EN 60335-1
EN 60335-2-41
EN 62233: 2008
EN 55014-1: 2017 + A11: 2020
EN 55014-2: 1997+A1: 2001+A2: 2008
EN 61000-3-2: 2014
EN 61000-3-3: 2013
EN IEC 63000: 2018
Conformity evaluation procedure used
2000/14/EC: Annex V
Sound power level dB(A)
BP 4.500 Garden
Measured: 68
Guaranteed: 71
BP 5.000 Garden
Measured: 70
Guaranteed: 73
BP 6.000 Garden
Measured: 81
Guaranteed: 84
BP 7.000 Garden
Measured: 81
Guaranteed: 83
The signatories act on behalf of and with the authority of the company management

H. Jenner Chairman of the Board of Management

S. Reiser Manager Regulatory Affairs & Certification

  • Documentation supervisor:
  • S. Reiser
  • Alfred Kärcher SE & Co. KG
  • Alfred-Kärcher-Str. 28 – 40
  • 71364 Winnenden (Germany)
  • Ph.: +49 7195 14-0
  • Fax: +49 7195 14-2212
  • Winnenden, 2021/06/01

Declaration of Conformity (UK)

We hereby declare that the product described below
complies with the relevant provisions of the following
UK Regulations, both in its basic design and construction as well as in the version put into circulation by us.
This declaration shall cease to be valid if the product is
modified without our prior approval.
Product: Pump
Type: 1.645-xxx
Currently applicable UK Regulations
S.I. 2008/1597 (as amended)
S.I. 2016/1091 (as amended)
S.I. 2001/1701 (as amended)
S.I. 2012/3032 (as amended)
S.I. 2010/2617 (as amended)
Commission Regulation(s)
(EU) 2019/1781
Designated standards used
EN 60335-1
EN 60335-2-41
EN 62233: 2008

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>