WIRING DIAGRAM
3 PHASE LOADING | NOMINAL AMPS PER PHASE |
---|---|
MODEL NUMBER | TOTAL CONN. kW |
CONNECTION** | **SINGLE |
PHASE
208 VOLT| 240 VOLT
X-Y| Y-Z| Z-X| X| Y| Z| X| Y| Z|
208 V| 240 V
36ESB-208| 4.50| 2.25| 2.25| 0.00| 11.0|
18.9| 11.0| 0.0| 0.0| 0.0| 21.6| 0.0
36ESB-240| 4.50| 2.25| 2.25| 0.00| 0.0|
0.0| 0.0| 9.4| 16.4| 9.4| 0.0| 18.8**
NOTE: CONNECT SUPPLY WIRES (90°C MIN) TO THE BROILER AS SHOWN, IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE, NFPA No. 70.
DERIVED FROM: 922778 REV B
MODELS
36ESB – 208
36ESB – 240
A13829
3 PHASE LOADING | NOMINAL AMPS PER PHASE |
---|
MODEL
NUMBER| TOTAL CONN.
kW| kW PER PHASE| 3 PHASE CONNECTION|
480 VOLT
X-Y| Y-Z| Z-X| X| Y| Z|
36ESB-480| 4.50| 2.25| 2.25| 0.00| 4.9|
8.4| 4.9|
NOTE: CONNECT SUPPLY WIRES (90°C MIN) TO THE BROILER AS SHOWN, IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE, NFPA No. 70.
DERIVED FROM: 922778 REV B
MODEL 36ESB – 480 A13830