DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)

NOTE: Telescopic downdraft vents are not recommended to be installed with cooktops that are flush mounted.

Approved for use with the following Monogram, GE Profile™ Series and GE® Series cooktops–36″ electric models, 36″ gas-sealed burner models and 36″ induction models.

FIG 1 DIMENSIONS AND INSTALLATION INFORMATION.JPG

NOT APPROVED FOR USE WITH STANDARD BURNER GAS COOKTOPS.
NOTE: The countertop must be at least 26″ deep with a flat surface area of 23-1/2″ or more, front to back. In addition, other clearances to the front edge of the countertop must be considered.

NOTE: Dimensions shown are for reference only.
Before cutting out countertop, refer to instructions packed with downdraft and cooktop.

NOTE: Installation on cabinets/countertops against the wall will not be possible in most applications.
Against the wall installations are limited to dimension requirements. Refer to installation instructions packed with product for further details.

VENTING DUCT INFORMATION

FIG 2 VENTING DUCT INFORMATION.JPG

PLAN THE DUCTWORK

  1. This downdraft blower system is designed for use with 3-1/4″ x 10″ ductwork (can be transitioned to 6″ round).
    Two different discharge directions are available with side to side adjustment for the accurate alignment of ductwork.

  2. For best performance: choose the ducting option which allows the shortest length of ductwork and a minimum number of elbows and transitions. Check location of floor joists, wall joists, wall studs, electrical wiring or plumbing for possible interference.

STEPS TO DETERMINE FLEXIBLE DUCTING’S EQUIVALENT LENGTH

  1. Measure the actual amount of offset (Maximum 3″ recommended). The effect upon airflow is dependent uponthe amount of offset.
  2. Calculate the equivalent ducting allowances using: (in. offset) x (14 ft. per inch) =ft. equivalent length.
  3. Total equivalent length of ducting should not exceed the maximum recommendation of 100 feet for optional venting performance.

FEATURES AND BENEFITS

500 CFM – Make sure everyone is focused only on your food with a 500-CFM venting system that removes smoke, grease, odors and moisture from the air.

Adjustable fan speed – Adjust your vents to match your cooking techniques with infinite fan control that removes grease, odors and moisture.

Grease filters – Keep your clean-up to a minimum with a removable

grease filter that helps eliminate hand scrubbing.

Aluminum mesh filters – Easy to remove, dishwasher safe.

Hides into countertop – Raises over cooktop surface and retracts when not in use.

Model UVD6361SPSS – Stainless Steel

FIG 4 FEATURES AND BENEFITS.JPG

For answers to your Monogram, Café™, GE Profile™ or GE Appliances product questions, visit our website at geappliances.com or call
GE Answer Center® Service, 800.626.2000.

Read More About This Manual & Download PDF:

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

GE Appliances User Manuals

Related Manuals