aldes EasyHOME Hygro COMPACT Premium Micro Watt Instruction Manual
- June 13, 2024
- aldes
Table of Contents
EasyHOME
Auto Classic
PureAIR Classic Installation and maintenance instructions
GENERAL INFORMATION
1.1. Description
1 | Outdoor discharge connection |
---|---|
2 | Bath/WC connection |
3 | Kitchen connection |
4 | Electric terminal block |
5 | Motorised fan unit |
6 | PCB |
7 | Wall attachment area |
8 | EasyHOME kitchen self- amplifier |
9 | EasyHOME bath self- amplifier |
10 | Discharge connector Ø160/125 |
11 | Bath controller |
12 | WC controller |
13 | Connection plug |
GPE EasyHOME Auto | Kit EasyHOME Auto |
ColorLINE ®** | GPE EasyHOME PureAIR CLASSIC |
EasyHOME PureAIR CLASSIC
---|---|---|---|---|---
N°| 11026031| 11026032 – 11035403| 11026033| 11033055| 11033056
1| 1| 1| 1| 1| 1
2| 4| 4| 4| 4| 4
3| 1| 1| 1| 1| 1
4| 1| 1| 1| 1| 1
5| 1| 1| 1| 1| 1
6| | | | 1| 1
7| 1| 1| 1| 1| 1
8| 1| 1| 1| 1| 1
9| | | | 2| 2
10| 1| 1| 1| 1| 1
11| 1| 1| 2| |
12| 1| 1| 2| 2| 2
13**| 2| 2| 2| 2| 2
1.2. Dimensions
1.3. Recommandations
Before installing, activating and maintaining this product, please read the «Precautions and regulatory information» data sheet provided.
ASSEMBLY
2.1. Recommandations
2.2. Installation plans
2.3. Suspended attachment
2.4. Screw attachment against wall (optional)
DUCT CONNECTIONS
Isolate the network, ex. volume heated
Connection using Algaine EasyClip (optional)
INSTALLATION OF TERMINALS
Installation in utility rooms and humid rooms
ELECTRICAL CONNECTION
Versie
Push button (optional)
MAINTENANCE
To retain its efficiency and operating characteristics, the CMEV system must be serviced regularly.
- Clean the exhaust terminals in accordance with the instructions provided
- Remove dust from air inlets in the main rooms or change the filters in accordance with the instructions provided.
Remove dust from the fan impeller using a brush.
WARRANTY
EasyHOME units come with a 2-year warranty subject to respect of the conditions of activation, use and servicing described in the instructions. Starts on the date of purchase. Date certified by distributor invoice.
ErP DATA SHEETS
| |
---|---|---
Supplier brand| Aldes| Aldes
Designation| EasyHOME Auto| EasyHOME PureAIR Classic
Energy class – Average climate| E| E
Average climate – SEC – Specific energy consumption (kWh/(m2 a year)| -12.57|
-18.20
Cold climate – SEC – Specific energy consumption (kWh/(m2 a year)| -28.98|
-39.13
Warm climate – SEC – Specific energy consumption (kWh/(m2 a year)| -3.18|
-6.15
Type of airflow| SF| SF
Declared type| UVR| UVR
Type of motor installed or planned| 2/ Two speed| 2/ Two speed
Type of heat recovery system| N/A| N/A
Thermal efficiency of heat recovery (%)| N/A| N/A
Maximum RVU (m3/h)| 241| 241
Electric power absorbed at Qmax (W)| 28.9| 28.9
LwA – Sound power level (dB)| 45| 45
Reference airflow (m3/s)| 0.05| 0.050
Difference in reference pressure (Pa)| 135| 135
SPI (W/(m3/h)| 0.15| 0.15
Control factor (%)| 1| 0.85
Type of control system| Manual Control| Central Demand Control
Maximum declared internal leakage rate under negative pressure for BVU (%)|
N/A| N/A
Maximum declared external leakage rate under negative pressure for UVU and
BVU (%)| 5.3| 5.3
Maximum declared internal leakage rate under positive pressure for BVU (%)|
N/A| N/A
Maximum declared external leakage rate under positive pressure for UVU and
BVU (%)| N/A| N/A
Mixing rate for standalone BVU without branch connections (%)| N/A| N/A
Position of visual alarm| N/A| N/A
Description of visual alarm| N/A| N/A
Regular replacement of filters to ensure unit performance and energy
efficiency| N/A| N/A
Instructions for installation of fresh air inlets| Cf. Notice| Cf. Notice
Sensitivity of airflow to pressure variations at +20 Pa| N/A| N/A
Sensitivity of airflow to pressure variations at -20 Pa| N/A| N/A
Indoor/outdoor air tightness (m3/h)| N/A| N/A
Annual electricity consumption (kWh electricity/a year)| 183| 151
Average climate – AHS – Annual heating savings (kWh primary energy/a year)|
1715| 2193
Cold climate – AHS – Annual heating savings (kWh primary energy/a year)|
3355| 4290
Warm climate – AHS – Annual heating savings (kWh primary energy/a year)| 776|
992
NOTES____
Need after sales technical support?
Visit our website for more information: https://www.aldes-
international.com/fr/contact/
www.aldes.com
20, boulevard Irène Joliot-Curie 69694 Vénissieux Cedex – France Aldes
EasyHOMEAutoClassicPureAIRClassic-Inst-11028849C
042022 – RCS 956 506 828
Printed in France