GENERAL INFORMATION

Description

1 Outdoor discharge connection
2 Bath/WC connection
3 Kitchen connection
4 Wall attachment area
5 Motor wiring seal
6 PCB
7 Electric terminal block
8 Kitchen humidity sensor
9 Bathroom humidity sensor
10 WC calibrated hole
11 Bathroom calibrated hole
12 Kitchen calibrated hole
13 Connection plug
14 Discharge connector Ø160/125
15 Modem
16 Sensor plug
GPE EasyHOME PureAIR Compact PREMIUM **Kit EasyHOME PureAIR Compact
PREMIUM** GPE EasyHOME PureAIR Compact CONNECT

Compact CONNECT
---|---|---|---|---
| 11033059| 11033060 – 11033077 – 11033082 11033083 – 11033084 – 11033085 11033086 – 11033087| 11033061| 11033062
1| 1| 1| 1| 1
2| 4| 4| 4| 4
3| 1| 1| 1| 1
4| 2| 2| 2| 2
5| 1| 1| 1| 1
6| 1| 1| 1| 1
7| 1| 1| 1| 1
8| 1| 1| 1| 1
9| 1| 1| 1| 1
10| 2| 2| 2| 2
11| 2| 2| 2| 2
12| 1| 1| 1| 1
13| 2| 2| 2| 2
14| | | |
15| | | 1| 1
16**| 2| 2| 2| 2

Dimensions


RECOMMENDATIONS

Before installing, activating and maintaining this product, please read the «Precautions and regulatory information» data sheet provided.

ASSEMBLY

Recommandations


Mounting

Installation plans

Screw-in attachment


ASSEMBLY


Assembly

DUCT CONNECTIONS

Isolate the network, ex. volume heated

Connection using Algaine EasyClip (optional


DEVICE CONNECTIONS

Grille connections

Installation in utility rooms and humid rooms

Connection of AldesConnect™ box

For the premium version, replace the USB cable of the AldesConnect™ Box using a 2 wire cable (2 x 0.75 mm², not supplied)
The sensors require a couple of minutes of self-calibration, during which the values displayed by the AldesConnect™ application should be ignored.

ELECTRICAL CONNECTION

Move the humidity sensors in front of the outlets connected to a bathroom. Assembly and disassembly by 1/4 turn.

Versie


Push button (optional) Do not connect to 230 V

MAINTENANCE

To retain its efficiency and operating characteristics, the CMEV system must be serviced regularly.

  • Clean the exhaust terminals in accordance with the instructions provided
  • Remove dust from air inlets in the main rooms or change the filters in accordance with the instructions provided.

Remove dust from the fan impeller using a brush.

WARRANTY

EasyHOME units come with a 2-year warranty subject to respect of the conditions of activation, use and servicing described in the instructions. Starts on the date of purchase. Date certified by distributor invoice.

ErP DATA SHEETS

EasyHOME PureAIR Compact Premium & Connect – Individual extract ventilation with multi-pollutant detection

Supplier brand Aldes
Designation EasyHOME PureAIR COMPACT Premium EasyHOME PureAIR COMPACT Connect
Energy class – Average climate B
Average climate – SEC – Specific energy consumption (kWh/(m2 a year) -54.12
Cold climate – SEC – Specific energy consumption (kWh/(m2 a year) -11.55
Warm climate – SEC – Specific energy consumption (kWh/(m2 a year) -20.92
Type of airflow SF
Declared type UVR
Type of motor installed or planned Variable speed
Type of heat recovery system NA
Thermal efficiency of heat recovery (%) NA
Maximum RVU (m3/h) 400
Electric power absorbed at Qmax (W) 70
LwA – Sound power level (dB) 44
Reference airflow (m3/s) 0.080
Difference in reference pressure (Pa) 50
SPI (W/(m3/h) 0.09
Control factor (%) 0.65
Type of control system Local Demand Control
Maximum declared internal leakage rate under negative pressure for BVU (%) NA

Maximum declared external leakage rate under negative pressure for UVU and BVU (%)| 0.4
Maximum declared internal leakage rate under positive pressure for BVU (%)| NA
Maximum declared external leakage rate under positive pressure for UVU and BVU (%)| NA
Mixing rate for standalone BVU without branch connections (%)| NA
Position of visual alarm| NA
Description of visual alarm| NA
Regular replacement of filters to ensure unit performance and energy efficien- cy| NA
Instructions for installation of fresh air inlets| Cf. Notice
Sensitivity of airflow to pressure variations at +20 Pa| NA
Sensitivity of airflow to pressure variations at -20 Pa| NA
Indoor/outdoor air tightness (m3/h)| NA
Annual electricity consumption (kWh electricity/a year)| 50
Average climate – AHS – Annual heating savings (kWh primary energy/a year)| 2830
Cold climate – AHS – Annual heating savings (kWh primary energy/a year)| 5536
Warm climate – AHS – Annual heating savings (kWh primary energy/a year)| 1280

site www.myaldes.com

OTHER COUNTRIES
Need after sales technical support?
Visit our website for more information:https://www.aldes- international.com/fr/contact/
www.aldes.com