aldes EasyHOME PureAIR Kit VMC Simple Flux Self Adjusting Instruction Manual
- June 13, 2024
- aldes
Table of Contents
aldes EasyHOME PureAIR Kit VMC Simple Flux Self Adjusting
GENERAL INFORMATION
Description
1 | Outdoor discharge connection |
---|---|
2 | Bath/WC connection |
3 | Kitchen connection |
4 | Wall attachment area |
5 | Motor wiring seal |
6 | PCB |
7 | Electric terminal block |
8 | Kitchen humidity sensor |
9 | Bathroom humidity sensor |
10 | WC calibrated hole |
11 | Bathroom calibrated hole |
12 | Kitchen calibrated hole |
13 | Connection plug |
14 | Discharge connector Ø160/125 |
15 | Modem |
16 | Sensor plug |
GPE EasyHOME PureAIR Compact PREMIUM | **Kit EasyHOME PureAIR Compact |
PREMIUM** | GPE EasyHOME PureAIR Compact CONNECT |
Compact CONNECT
---|---|---|---|---
N°| 11033059| 11033060 – 11033077 – 11033082 11033083 – 11033084 –
11033085 11033086 – 11033087| 11033061| 11033062
1| 1| 1| 1| 1
2| 4| 4| 4| 4
3| 1| 1| 1| 1
4| 2| 2| 2| 2
5| 1| 1| 1| 1
6| 1| 1| 1| 1
7| 1| 1| 1| 1
8| 1| 1| 1| 1
9| 1| 1| 1| 1
10| 2| 2| 2| 2
11| 2| 2| 2| 2
12| 1| 1| 1| 1
13| 2| 2| 2| 2
14| | | |
15| | | 1| 1
16**| 2| 2| 2| 2
Dimensions
RECOMMENDATIONS
Before installing, activating and maintaining this product, please read the «Precautions and regulatory information» data sheet provided.
ASSEMBLY
Recommandations
Mounting
Installation plans
Screw-in attachment
ASSEMBLY
DUCT CONNECTIONS
Isolate the network, ex. volume heated
Connection using Algaine EasyClip (optional
DEVICE CONNECTIONS
Grille connections
Installation in utility rooms and humid rooms
Connection of AldesConnect™ box
For the premium
version, replace the USB cable of the AldesConnect™ Box using a 2 wire cable
(2 x 0.75 mm², not supplied)
The sensors require a couple of minutes of self-calibration, during which the
values displayed by the AldesConnect™ application should be ignored.
ELECTRICAL CONNECTION
Move the humidity sensors in front of the outlets connected to a bathroom. Assembly and disassembly by 1/4 turn.
Versie
Push button (optional) Do not connect to 230 V
MAINTENANCE
To retain its efficiency and operating characteristics, the CMEV system must be serviced regularly.
- Clean the exhaust terminals in accordance with the instructions provided
- Remove dust from air inlets in the main rooms or change the filters in accordance with the instructions provided.
Remove dust from the fan impeller using a brush.
WARRANTY
EasyHOME units come with a 2-year warranty subject to respect of the conditions of activation, use and servicing described in the instructions. Starts on the date of purchase. Date certified by distributor invoice.
ErP DATA SHEETS
EasyHOME PureAIR Compact Premium & Connect – Individual extract ventilation with multi-pollutant detection
Supplier brand | Aldes |
---|---|
Designation | EasyHOME PureAIR COMPACT Premium EasyHOME PureAIR COMPACT Connect |
Energy class – Average climate | B |
Average climate – SEC – Specific energy consumption (kWh/(m2 a year) | -54.12 |
Cold climate – SEC – Specific energy consumption (kWh/(m2 a year) | -11.55 |
Warm climate – SEC – Specific energy consumption (kWh/(m2 a year) | -20.92 |
Type of airflow | SF |
Declared type | UVR |
Type of motor installed or planned | Variable speed |
Type of heat recovery system | NA |
Thermal efficiency of heat recovery (%) | NA |
Maximum RVU (m3/h) | 400 |
Electric power absorbed at Qmax (W) | 70 |
LwA – Sound power level (dB) | 44 |
Reference airflow (m3/s) | 0.080 |
Difference in reference pressure (Pa) | 50 |
SPI (W/(m3/h) | 0.09 |
Control factor (%) | 0.65 |
Type of control system | Local Demand Control |
Maximum declared internal leakage rate under negative pressure for BVU (%) | NA |
Maximum declared external leakage rate under negative pressure for UVU and BVU
(%)| 0.4
Maximum declared internal leakage rate under positive pressure for BVU (%)| NA
Maximum declared external leakage rate under positive pressure for UVU and BVU
(%)| NA
Mixing rate for standalone BVU without branch connections (%)| NA
Position of visual alarm| NA
Description of visual alarm| NA
Regular replacement of filters to ensure unit performance and energy efficien-
cy| NA
Instructions for installation of fresh air inlets| Cf. Notice
Sensitivity of airflow to pressure variations at +20 Pa| NA
Sensitivity of airflow to pressure variations at -20 Pa| NA
Indoor/outdoor air tightness (m3/h)| NA
Annual electricity consumption (kWh electricity/a year)| 50
Average climate – AHS – Annual heating savings (kWh primary energy/a year)|
2830
Cold climate – AHS – Annual heating savings (kWh primary energy/a year)| 5536
Warm climate – AHS – Annual heating savings (kWh primary energy/a year)| 1280
site www.myaldes.com
OTHER COUNTRIES
Need after sales technical support?
Visit our website for more information:https://www.aldes-
international.com/fr/contact/
www.aldes.com
20, boulevard Irène Joliot-Curie 69694 Vénissieux Cedex – France
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>