Klimair 160RE Heat Exchanger User Guide

June 13, 2024
Klimair

UNOKLIMA
160RE
XT160
QUICK-GUIDEKlimair 160RE Heat Exchanger

CONNECTIONS

BEFORE THE FIRST OPERATION IT IS RECOMMENDED TO READ THE COMPLETE INSTRUCTION MANUAL TO PREVENT ANY DAMAGE TO THE PRODUCT.

ELECTRICAL CONNECTIONS

MODEL BASE direct connectionKlimair 160RE Heat Exchanger - fig
1MODEL BASE connection with wall switch (not provided)Klimair 160RE Heat Exchanger - fig 2MODEL REMOTE single unit connectionKlimair 160RE Heat Exchanger - fig
3REMOTE MASTER-SLAVE connection
WARNING: During this stage all the products must have the main switch on “0”Klimair 160RE Heat Exchanger - fig 4 WARNING:
Humidity and twilight sensors will detect the values from the first unit connected. Al systems with long wires or with a lot of electric/electronic equipment may cause signal disturbance. Use shielded cables and connect a termination resistor of 120ohm on pin 3 and 4 of the terminal block of the last SLAVE unit.
160RE – XT160 QUICK CONFIGURATIONS
BEFORE THE FIRST OPERATION IT IS RECOMMENDED TO READ THE COMPLETE INSTRUCTION MANUAL TO PREVENT ANY DAMAGE TO THE PRODUCT.
CONFIGURATION on MASTER-SLAVE installation only
MODEL BASE has a direct connection and operates directly with the switch on the left side of the unit. No configuration required.
MODEL REMOTE
For configuration, please follow the instructions below, taking into consideration that the first unit installed will be the MASTER and all the other units in sequence SLAVE-OPPOSITE TO-MASTER and SLAVE-SAME AS- MASTER.Klimair 160RE Heat Exchanger - fig 5

Unit 1
MASTER| Unit 2
SLAVE OPPOSITE
TO MASTER| Unit 3
SLAVE SAME
AS MASTER| Unit 4
SLAVE OPPOSITE
TO MASTER| Unit 5
ETC…
---|---|---|---|---

WARNING:
The MASTER is the only unit receiving commands from remote control, that will detect the ambient conditions through the sensors and thus controlling all the system.

OPERATIONS OVERVIEW

BEFORE THE FIRST OPERATION IT IS RECOMMENDED TO READ THE COMPLETE INSTRUCTION MANUAL TO  PREVENT ANY DAMAGE TO THE PRODUCT.
MODEL REMOTE follow the remote functions below:
MODEL BASE:
I:0 = on/off
I:II = speed 1 or 2Klimair 160RE Heat Exchanger - fig
6

Features Mode| Button for selection| Screen display| Humidity sensor| Twilight sensor| Shutter| Standard
operation| Operation in alarm
---|---|---|---|---|---|---|---
AUTOMATIC| | | Activated| Activated| Open| Heat recovery| Extraction
SURVEILLANCE| | | Activated| Activated| Closed| Standby| Extraction
MANUAL| | | Not activated| Not activated| Open| Heat recovery| Not activated
NIGHT| | | Not activated| Not activated| Open| Heat recovery| Not activated
TIMED BOOST EXTRACTION| | | Not activated| Not activated| Open| Extraction| Not activated
MASTER SLAVE AIR FLOW| | | Not activated| Not activated| Open| Air flow| Not activated
SLAVE MASTER AIR FLOW| | | Not activated| Not activated| Open| Air flow| Not activated
EXTRACTION| | | Not activated| Not activated| Open| Extraction| Not activated
INTAKE| | | Not activated| Not activated| Open| Intake| Not activated

160RE
www.ahlsell-vvs.dk
info@ahlsell-vvs.dk
0045 3819 0000
UNOKLIMA
XT160
www.vvs-trading.dk
salg@vvs-trading.dk
0045 7342 4300
13-04-2021

References