NEWGRIND RS150 Electric Floor Grinder and Polisher User Manual
- June 13, 2024
- NEWGRIND
Table of Contents
- RS150 Electric Floor Grinder and Polisher
- Rhino RS150 diagram
- Rhino RS150 bottom diagram
- Rhino RS150 machine specifications
- Rhino RS150 safety instructions
- Rhino RS150 changing tools and accessories
- Rhino RS150 grinder maintenance
- Rhino RS150 trouble shooting and diagnostics
- 03
- Limited equipment warranty of sale
- TERMS & CONDITIONS
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
user Manual – VFd: Lenze version
equipment usages
RS150 Electric Floor Grinder and Polisher
- Concrete leveling, grinding and polishing
- Glue, thinset and mastic removal
- Terrazzo grinding and polishing
- Stone grinding and polishing
- Hardwood sanding and refinishing
For your personal safety, READ and UNDERSTAND before using.
SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
Rhino RS150 diagram
Rhino RS150 bottom diagram
Rhino RS150 machine specifications
POWER | 15 AMP/120V |
---|---|
MAXIMUM WATTS DRAW | 1776 |
HP | 1.5 |
MACHINE WEIGHT | 150 lbs |
BIASED WEIGHT KIT MAX WEIGHT | 175 lbs |
COMBINED WEIGHT | 325 |
DISC SPEED | 200-900 rpm |
VARIABLE SPEED CONTROL | YES |
NUMBER OF GRINDING HEADS | 6 |
COUNTER-ROTATING HEADS | YES |
DISK SIZE | 5 inches |
GRINDING FOOTPRINT | 14 inches |
QUICK CHANGE TOOLING | YES |
QUICK BELT CHANGING SYSTEM | YES |
WET OR DRY GRINDING | YES |
UHMW FLOATING DUST SKIRT | YES |
MULTI-ARTICULATING HANDLE | YES |
RUNS FORWARD OR REVERSE | YES |
CAN BE USED AS AN EDGER | YES – grinds to within 1/8 of the edge |
DUAL VACUUM MANIFOLDS | YES |
Tooling
RHINO STYLE TOOLING | YES |
---|---|
STANDARD TRAPEZOID | NO |
Average Production Rates
(on Medium Hard Concrete)
EXTREMELY HEAVY REMOVAL | 100-150 sq./ft. per hour |
---|---|
HEAVY REMOVAL | 200-300 sq./ft. per hour |
LIGHT REMOVAL | 250-400 sq./ft. per hour |
GRINDING AND PROFILING | 300-450 sq./ft. per hour |
POLISHING | 400-650 sq./ft. per hour |
Rhino RS150 safety instructions
WARNING! Read and understand all instructions.
Failure to follow all instructions listed below, may result in electric shock,
fire and/or serious personal injury.
SAVE THESE INSTRUCTIONS.
Work Area Safety
- Keep your work area clean and well lit. Cluttered floors and dark areas invite accidents.
- Do not operate equipment in explosive environments, such as in the presence of – flammable liquids, gases or dust. Grinding can create sparks which may ignite the dust or fumes.
- Keep bystanders, children, and visitors away while operating equipment. Distractions can cause you to lose control.
Electrical Safety
-
Do not abuse the cord. Never use the cord to pull the equipment or pull the plug from an outlet.
Keep cord away from heat, oil, sharp edges or moving parts. Replace damaged cords immediately.
Damaged cords increase the risk of electric shock. -
Make sure cord is clear of wheels and cutting discs. Do not wrap cord around your arm or wrist.
If control of equipment is lost, cord may become wrapped around you and cause personal injury. -
When operating equipment outside, use an outdoor extension cord marked “W-A” or “W”. These cords are rated for outdoor use and reduce the risk of electric shock.
-
Avoid accidental starting. Be sure stop button is depressed before plugging in. Starting equipment with your finger on the start buttons or plugging in equipment that has the buttons depressed invites accidents.
-
USE THE PROPER EXTENSION CORD. Make sure your extension cord is in good condition. When using an extension cord, be sure to use one heavy enough to carry the current your product will draw. An undersized cord will cause a drop in line voltage resulting in loss of power and overheating.
FOR THE RS150 USE 14-GAUGE CORD OR LARGER.
Personal Safety
-
DO NOT let comfort or familiarity with product (gained from repeated use) replace strict adherence to equipment safety rules. If you use this equipment unsafely or incorrectly, you can suffer serious personal injury.
-
Stay alert, watch what you are doing and use common sense when operating equipment.
Do not use equipment while tired or under the influence of drugs, alcohol, or medication. A moment of inattention while operating equipment may result in serious personal injury. -
Adequate ventilation of your work area is very important when using equipment.
Use a dust mask or appropriate respirator. -
Do not overreach. Always keep proper footing and balance. Proper footing and balance will enable better control of the equipment in unexpected situations.
-
Use safety equipment. Always wear eye protection, dust mask, non-skid safety shoes, hard hat and hearing protection. Ordinary eye or sunglasses are NOT eye protection.
-
DO NOT Turn on equipment while the machine is tilted back. Any tooling plates mounted on the machine can come off and cause damage or injury.
Equipment Safety and Care
-
The equipment is designed to remove excess surface material. To prevent damage to the equipment and/or serious personal injury, beware of protruding objects or other debris on or embedded in the surface being finished.
-
Disconnect the plug from the power source before making any adjustments, changing accessories, or storing equipment. Such preventive safety measures reduce the risk of starting the equipment accidentally.
-
Maintain equipment with care. Keep tools and accessories in good condition. Properly maintained tools with sharp cutting edges are less likely to fail and are easier to control.
-
Check for binding of moving parts, breakage of parts, and any other condition that mayaffect the equipment’s operation. If damaged, have equipment serviced before using.
Many accidents are caused by poorly maintained equipment. -
Use only tools and accessories that are recommended by the manufacturer for your equipment.
Tools and accessories that may be suitable for style of equipment, may become hazardous when used on another style of equipment. -
Tools and accessories must be rated for at least the speed stated on the equipment serial plate.
Tools and other accessories running faster than rated speed can fly apart and cause injury. -
Due to the dusty nature during use of this equipment, be sure to clean equipment often to remove dust accumulations. Carefully blow the dust out of the motor, VFD and dust covered areas frequently.
-
Always install the dust skirt before operation.
-
Check the tools and accessories carefully for cracks or damage before operation. Replace cracked or damaged tools or and accessories immediately.
-
Hold the equipment firmly with both hands during operation.
-
Do not leave the equipment running unattended.
-
Do not touch the tools immediately after operation; they may be extremely hot and could burn your skin.
Service Safety
- DO NOT modify the machine. Modifications will void warranty and could result in unsafe operation of equipment.
- Equipment service should be performed only by qualified repair personnel. Service or maintenance performed by unqualified personnel could result in a risk of injury.
- When servicing equipment, use only identical replacement parts. Use of unauthorized parts may create a risk of electric shock or injury.
WARNING:
Misuse or failure to follow the safety rules stated in this instruction manual
may cause serious personal injury.
SAVE THESE INSTRUCTIONS.
Rhino RS150 operating the grinder
The machine is outfitted with a Variable Frequency Drive (VFD) enabling the
user to select the desired operating speed.
The equipment can operate on either 50 Hz or 60 Hz frequencies.
The VFD will automatically adjust for phase or frequency input which will
raise or lower head speed on the machine.
VFD features:
- Under voltage protection – Over current protection
- 60Hz and 50Hz capability (international)
- 110V
- Soft start
- Speed display
- Load display
- Current limiting
NOTE:
LED DISPLAY – Shows PAD speed when machine is running and says “STOP” when
plugged in but not running.
Prior to using the grinder
-
Inspect the grinder to make sure all bolts are tight, and that tools are properly mounted.
-
Check that the plug is properly connected to the extension cord and inspect the cord for wear and tear.
-
Make sure that speed dial is turned to its lowest setting.
WARNING:
This will prevent unexpected high speed start up which could cause some tools to eject or cause undesirable marks to the surface being finished. -
Plug the machine in – the VFD LED should read “STOP”
Starting the grinder
DO NOT LIFT THE EQUIPMENT OFF THE GROUND WHILE STARTING!
Doing so can cause the tools to release from the equipment and cause damage to
the surface being finished and harm to the user!
-
With the machine in an upright position, set the articulating handle to the desired position.
-
Check that speed dial is set to slowest speed.
-
Plug the power cable in, making sure that extension cord is not tangled or wrapped around any obstacles.
-
Ensure that the VFD LED reads “STOP”
-
Apply downward pressure on the handle to alleviate some pressure on the tools and press the GREEN start button. (If you want the machine to run in reverse you can push the yellow start button.
NOTE:
Always use the equipment in the forward rotation mode (green button) unless reverse rotation is needed.
This will ensure consistent tool wear.
The use of the equipment in the reverse rotation is only needed when surface being finished is uneven and causes the equipment to pull in an undesired direction or when the tooling is glazed and needs to be re-dressed. -
Once the equipment is started, gently release the downward pressure and start grinding.
NOTE:
The equipment is designed to rotate the tooling in either the forward
direction (green button) or reverse direction (yellow button) depending on
operating needs.
Adjusting the speed
- Use the knob, located on the right side of the handle control box to adjust speed of equipment.
Stopping the equipment
- To stop the equipment, turn speed control knob to the slowest setting and,
- push the red stop button on the face of the handle.
Adjusting the handle
- Make sure machine is unplugged.
- Pull the hand latch or step on foot latch on the handle and move handle up or down to the desired position.
Avoid stepping on or tangling handle control cable when adjusting the handle position.
Make sure that the latch clicks in place when the desired position is achieved.
WARNING:
Failure to check for positive handle latch engagement could result in damage
to the equipment or injury to the user as the handle could release
unexpectedly when the machine is being operated or tilted back!
Using the biased weight kit
The Rhino line of equipment was designed to be used with our biased weight
kit, which allows our machines to be loaded with weights to increase point
pressure for very hard floors and to rapidly expose aggregate.
Our unique patented biased weight system uses standard Olympic weight plates,
allowing placement on either side of the machine to increase pressure when
grinding edges with slab curl and high and low spots.
Weights can also be placed on the handle to alleviate pressure and weight from
the machine, enabling the Rhino to be easily and effectively used for soft &
rained out slabs.
For best results and to increase production we highly recommend utilizing
weights with your Rhino grinder.
Changing the drive belt
To view a video on how to change the drive belt – please visit our website at:
www.newgrind.com
Rhino RS150 changing tools and accessories
WARNING:
Always turn grinder off and disconnect power from the machine when performing
any operations to the bottom of the machine!
When removing and inserting tool plates or adapter plates, be sure to inspect
rubber grommets for signs for wear and replace any damaged grommets.
WARNING:
Using grommets that are damaged or missing can cause unexpected equipment
operation and increase the chance of tool plate / adapter plate ejection or
violent vibration leading to loss of control of equipment.
To change the tools:
-
Turn grinder off, and unplug power
-
Use the weight kit peg on the lower part of the handle to help you tilt the machine back. Do not step on handle release pedal to tilt back as this may disengage the lower ratchet and cause operator to lose balance and cause possible injury.
WARNING:
Do not attempt to replace tools that have recently been in use as they may be hot and could cause injury.
-
Grasp the tool plate firmly with both hands and pull to remove tool plate from grommets
-
Remove the bolt from the back of the tool plate behind each tool to release the tool
-
Hold the replacement tool up against the desired slot on the tool plate and insert/tighten the bolt.
NOTE:
Rhino tool plates have spaces for up to 6 tools. Using 3 evenly spaced tools per plate is standard configuration. -
Inspect the grommets to make sure they are not worn or missing
-
Reinsert tool plate into rubber grommets
-
Hold the plate firmly with both hands and jiggle it to make sure its properly attached
-
Repeat with each of the tool plates
WARNING:
Only use tools that have been designed for the machine, and make sure that the same type of tool is being used on all plates/positions. -
Gently tilt machine back to upright position by lifting the handle and placing your foot on one of the lower handle weight posts.
DO NOT drop the machine on to the floor, as this may cause damage to the floor and/or tooling. -
Follow the procedure for starting the grinder
Parts and accessories
A full range of parts and accessories for all of our grinders is available on
our websit
Rhino RS150 grinder maintenance
WARNING:
Disconnect power before performing any maintenance, cleaning, or repair to
your equipment!
General Maintenance
- When the equipment is not in use, make sure that the adapter plate assemblies have something attached to them to protect the Velcro. Resting the machine directly on unprotected Velcro will crush the fastening material causing the Velcro to become unusable.
Daily Maintenance
- Wipe down the equipment after every job.
- Gently remove dirt and debris from the Velcro hook material using a stiff brush. This will ensure maximum adhesion.
- Check that the handle bolts are tight.
- Vacuum or wipe underside of machine.
- Inspect plug ends for signs of carbon deposits or arcing.
- Check all fasteners and tighten if necessary.
Monthly Maintenance
- Inspect handle wires for damage.
- Blow off the VFD heat sink with compressed air.
- Blow out VFD cooling fan(s) with low pressure compressed air (30psi or less).
- Cleaning the fan(s) prevents fan failure and potential VFD overheating. Do not over-speed the fan(s) with compressed air!
- Blow off motor fan with compressed air.
- Remove tool plate holders and wipe down bearing shields with a damp cloth. Do not use any sharp object or abrasive pad to clean the bearing shields. This can compromise the bearing seal!
- Using a soft scrub pad, remove any excess dirt build up from the bottom plate and back side of pad drivers.
- Inspect tool plate driver grommets for signs of wear. Replace grommets that show signs of extensive wear.
Yearly Maintenance
- Check all strain reliefs and make sure they are tight so as to avoid cords being pulled out of the VFD or handle.
- Clean and lubricate wheels.
- Clean and lubricate latch mechanisms.
Rhino RS150 trouble shooting and diagnostics
VFD fault messages
The messages below show how they will appear on the display when the drive
trips.
When looking at the fault history (P500), the will not appear in the fault
message.
Status/warning messages
STATUS/WARNING | CAUSE | REMEDY |
---|---|---|
DC-injection brake active | DC-injection brake activated |
• activation of digital input (P121…P124 = 18)
• automatically (P110 = 2, 4…6)
• automatically (P111 = 1, 3)| Deactivate DC-injection brake
• deactivate digital input
• automatically after P175 time has expired
| Drive ID warning| The Drive ID (P502) stored on the EPM does not match the
drive model.| • Verify motor data (P302…P306) and perform Auto Calibration.
• Set drive mode (P300) to 0 or 1
• Reset the drive (P199 to 3 or 4) and reprogram.
| Motor Auto-calibration active| Refer to P300, P399| Motor Auto-calibration
is being performed
| An EPM that contains valid data from a previous software version has been
installed| An attempt was made to change parameter settings| Parameter
settings can only be changed after the EPM data is converted to the current
version (P199 = 5)
| Current Limit (P171) reached| Motor overload| • Increase P171
• Verify drive/motor are proper size for application
| Decel Override| The drive has stopped decelerating to avoid tripping into HF
fault, due to excessive motor regen (2 sec max).| If drive trips into HF
fault:
• Increase P105, P126
• Install Dynamic Braking option
| Error| Invalid data was entered, or an invalid command was attempted|
| Fast Current Limit| Fast Current Limit| Verify drive/motor are proper size
for application
| Flying Restart Attempt after Fault| P110 = 5,6|
| OEM Settings Operation warning| An attempt was made to change parameter
settings while the drive is operating in OEM Settings mode.| In OEM Settings
mode (P199 = 1), making changes to parameters is not permitted.
| OEM Defaults data warning| An attempt was made to use (or reset to) the OEM
default settings (P199 = 1 or 2) using an EPM without valid OEM data.| Install
an EPM containing valid OEM Defaults data
| Fault Lockout| The drive attempted 5 restarts after a fault but all attempts
were unsuccessful (P110 = 3…6)| • Drive requires manual reset
• Check Fault History (P500) and correct fault condition
| PID Deceleration Status| PID setpoint has finished its ramp but the drive is
still decelerating to a stop.|
| PID Mode Active| Drive has been put into PID Mode.| Refer to P200
| Sleep Mode is active| Refer to P240…P242|
| Start Pending| The drive has tripped into a fault and will automatically
restart (P110 = 3…6)| To disable Auto-Restart, set P110 = 0…2
| PID Mode disabled.| Drive has been taken out of PID Mode. Refer to P200.|
| Output frequency = 0 Hz (outputs U, V, W inhibited)| Stop has been commanded
from the keypad, terminal strip, or network| Apply Start command (Start
Control source depends on P100)
Drive configuration messages
When the Mode button is pressed and held, the drive’s display will provide a
4-digit code that indicates how the drive is configured. If the drive is in a
Stop state when this is done, the display will also indicate which control
source commanded the drive to Stop (the two displays will alternate every
second).
Configuration display
Format = x.y.zz| x = Control Source:
| y = Mode:
| zz = Reference:
---|---|---|---
| Example:
= Local Keypad Start control, Speed
mode, Keypad speed reference
= Terminal Strip Start control, PID mode, 0-10 VDC setpoint reference
= Terminal Strip Start control, Sequencer Operation (Speed mode), Segment #12
= Network Start control, Vector Torque mode, Preset Torque #2 reference
= Network Start control, Speed mode, Speed reference from Sequencer segment
03
Format = x.StP| = Stop command came from Local Keypad
= Stop command came from Terminal Strip
= Stop command came from Remote Keypad
= Stop command came from Network
Fault messages
The messages below show how they will appear on the display when the drive
trips.
When looking at the Fault History (P500), the will not appear in the fault
message.
FAULT | CAUSE | REMEDY (¹) |
---|---|---|
High Temperature fault | Drive is too hot inside | • Reduce drive load |
• Improve cooling
| Assertion Level fault| • Assertion Level switch is changed during operation
• P120 is changed during operation
• P100 or P121…P124 are set to a value other than 0 and P120 does not match
the Assertion Level Switch.| • Make sure the Assertion Level switch and P120
are both set for the type of input devices being used, prior to setting P100
or P121…P124.
Refer to 3.2.3 and P120.
| Personality fault| Drive Hardware| • Cycle Power
• Power down and install EPM with valid data
• Reset the drive back to defaults (P199 = 3, 4) and then re-program
• If problem persists, contact factory technical support
| Control fault| An EPM has been installed that is either blank or corrupted
| Incompatible EPM fault| An EPM has been installed that contains data from an
incompatible parameter version
| Forced Translation fault| An EPM from an old drive put in new drive causes
drive to trip _FcFT fault.| Press [M] (mode button) twice to reset
| Dynamic Braking fault| Dynamic braking resistors are overheating| • Increase
active decel time (P105, P126, P127).
• Check mains voltage and P107
| External fault| • P121…P124 = 21 and that digital input has been opened.
• P121…P124 = 22 and that digital input has been closed.| • Correct the
external fault condition
• Make sure digital input is set properly for NC or NO circuit
| EPM fault| EPM missing or defective| Power down and replace EPM
| Internal faults| | Contact factory technical support
| Control Configuration Fault| The drive is setup for REMOTE KEYPAD control
(P100=2 or 5) but is not setup to communicate with a remote keypad| Set P400 =
1, or P600 = 1
__| | Set P400 or P600 to a valid network communications protocol
selection| Set P400 or P600 to a valid network communications protocol
selection
| TB25 (4-20 mA signal) Threshold fault| 4-20 mA signal (at TB-25) drops below
the value set in P164.| • Check signal/signal wire
• Refer to parameters P163 and P164.
| OEM Defaults data fault| Drive is powered up with P199 =1 and OEM settings
in the EPM are not valid.| Install an EPM containing valid OEM Defaults data
or change P199 to 0.
| High DC Bus Voltage fault| Mains voltage is too high| Check mains voltage
and P107
__| | Decel time is too short, or too much regen from motor| Increase
active decel time (P105, P126, P127) or install Dynamic Braking option
| Digital Input Configuration fault (P121 … P124)| More than one digital input
set for the same function| Each setting can only be used once (except settings
0 and 3)
__| | Only one digital input configured for MOP function (Up, Down)|
One input must be set to MOP Up, another must be set to MOP Down
__| | PID mode is entered with setpoint reference and feedback source
set to the same analog signal| Change PID setpoint reference (P121…P124) or
feedback source (P201).
__| | One of the digital inputs (P121…P124) is set to 10 and another is
set to 11…14.| Reconfigure digital inputs
__| | One of the digital inputs (P121…P124) is set to 11 or 12 and
another is set to 13 or 14.|
__| | PID enabled in Vector Torque mode (P200 = 1 or 2 and P300 = 5)|
PID cannot be used in Vector Torque mode
| Remote keypad fault| Remote keypad disconnected| Check remote keypad
connections
| Low DC Bus Voltage fault| Mains voltage too low| Check mains voltage
| No Motor ID fault| An attempt was made to start the drive in Vector or
Enhanced V/Hz mode prior to performing the Motor Auto-calibration| Refer to
parameters P300…P399 for Drive Mode setup and calibration.
| Module communication fault| Communication failure between drive and Network
Module.| Check module connections
| Network Faults| Refer to the module documentation for Causes and Remedies.|
| Output fault: Transistor fault| Output short circuit| Check motor/motor
cable
__| | Acceleration time too short| Increase P104, P125
__| | Severe motor overload, due to:
• Mechanical problem
• Drive/motor too small for application| • Check machine / system
• Verify drive/motor are proper size for application
__| | Boost values too high| Decrease P168, P169
__| | Excessive capacitive charging current of the motor cable| • Use
shorter motor cables with lower charging current
• Use low capacitance motor cables
• Install reactor between motor and drive.
__| | Failed output transistor| Contact factory technical support
| Output fault: Ground fault| Grounded motor phase| Check motor and motor
cable
__| | Excessive capacitive charging current of the motor cable| Use
shorter motor cables with lower charging current
| Motor Overload fault| Excessive motor load for too long| • Verify proper
setting of P108
• Verify drive and motor are proper size for application
| Flying Restart fault| Controller was unable to synchronize with the motor
during restart attempt; (P110 = 5 or 6)| Check motor / load
| Single-Phase fault| A mains phase has been lost| Check mains voltage
| Start fault| Start command was present when power was applied (P110 = 0 or
2).| • Must wait at least 2 seconds after power-upto apply Start command
• Consider alternate starting method (P110).
| TB5 (0-10V signal) Threshold fault| 0-10V signal (at TB5) drops below the
value set in P158.| • Check signal/signal wire
• Refer to parameters P157 and P158
(1) The drive can only be restarted if the error message has been reset.
The VFD is protected from voltage fluctuations within the specified voltage
range. Check voltage before plugging in equipment to insure safe operation.
WARNING:
If a machine is plugged into a power source that is above the machine’s
maximum voltage
capability (ex. 230V model plugged into a 460V power source) this will damage
and/or destroy
the internals of the VFD and void the warranty!
Limited equipment warranty of sale
NewGrind Inc. warrants that each new unit manufactured by NewGrind Inc. to be
free from defects in material and workmanship in normal use and service for a
period of (3) three years from date of shipment to the original owner.
Accessories or equipment furnished and installed on the product by NewGrind
Inc. but manufactured by others, including, but not limited to engines,
motors, electrical components, transmissions etc., shall carry the accessory
manufacturers own warranty.
NewGrind Inc. will, at its option, repair or replace, at the NewGrind Inc.
factory or at a point designated by NewGrind Inc. any part which shall appear
to the satisfaction of NewGrind Inc. inspection to have been defective in
material or workmanship. NewGrind Inc. reserves the right to modify, alter and
improve any part or parts without incurring any obligation to replace any part
or parts previously sold without such modified, altered or improved part or
parts.
This warranty is in lieu of and excludes all other warranties, expressed,
implied, statutory, or otherwise created under applicable law. In no event
shall seller or the manufacturer of the product be liable for special,
incidental, or consequential damages, including loss of profits, whether or
not caused by or resulting from the negligence of seller and/or the
manufacturer of the product unless specifically provided herein.
In addition, this warranty shall not apply to any products or portions there
of which have been subjected to abuse, misuse, improper installation,
maintenance, or operation, electrical failure or abnormal conditions and to
products which have been tampered with, altered, modified, repaired, reworked
by anyone not approved by seller or used in any manner inconsistent with the
provisions of the above or any instructions or specifications provided with or
for the product.
Force majeure
Seller’s obligation hereunder are subject to, and Seller shall not be held
responsible for, any delay or failure to make delivery of all or any part of
the product due to labor difficulties, fires, casualties, accidents, acts of
the elements, acts of God, transportation difficulties, delays by a common
carrier, inability to obtain product, materials or components or qualified
labor sufficient to timely perform part of or all of the obligations contained
in these terms and conditions, governmental regulations or actions, strikes,
damage to or destruction in whole or part of manufacturing plant, riots,
terrorist attacks or incidents, civil commotions, warlike conditions, flood,
tidal waves, typhoon, hurricane, earthquake, lightning, explosion or any other
causes, contingencies or circumstances within CANADA not subject to the
Seller’s control which prevent or hinder the manufacture or delivery of the
products or make the fulfillment of these terms and conditions impracticable.
In the event of the occurrence of any of the foregoing, at the option of
Seller, Seller shall be excused from the performance under these Terms and
Conditions, or the performance of the Seller shall be correspondingly
extended.
This document sets forth the terms and conditions pursuant to which the
purchaser (“Purchaser”) will purchase and New Grind Inc. (“Seller”) will sell
the products, accessories, attachments (collectively the products “) ordered
by the Purchaser. These terms and conditions shall govern and apply to the
sale of Seller’s products to Purchaser, regardless of any terms and conditions
appearing on any purchase order or other forms submitted by Purchaser to
Seller, or the inconsistency of any terms therein and herein.
LIABILITY LIMITATIONS
The remedies of the user set forth under provisions of warranty outlined above are the exclusive and total liability of New Grind Inc. with the respect to their sale or the equipment and service furnished hereunder, in connection with the performance or breach thereof, or from the sale, delivery, installation, repair or technical direction covered by or furnished under the sale, whether based on contract, warranty, negligence, indemnity, strict liability, or otherwise shall not exceed the purchase price of the unit of equipment upon which such liability is based. New Grind Inc. will not in any event be liable to the user, any successors in interest or any beneficiary or assignee relating to this sale for any consequential, incidental, indirect, special or punitive damages arising out of this sale or any breach thereof, or any defects on, or failure of, or malfunction of the equipment under this sale based upon loss of use, lost profits or revenue, interest, lost goodwill, work stoppage, impairment of other goods, loss by reason of shutdown or nonoperation, increased expenses of operation of the equipment, cost of purchase or replacement power of claims of users or customers of the user for service interruption whether or not such loss or damage is based on contract, warranty, negligence, indemnity, strict liability, or otherwise. New Grind Inc. reserves the right to modify, alter and improve any part or parts without incurring any obligation to replace any part or parts previously sold without such modified, altered or improved part or parts. No person is authorized to give any other warranty or to assume any additional obligation on New Grind Inc.’s behalf unless made in writing and signed by an officer of New Grind Inc.
TERMS & CONDITIONS
-
PRICE
All prices set forth on any purchase order or other document are F.O.B. Sellers facility or distribution point, as may be determined by Seller (F.O.B. Point). All prices are exclusive of any and all taxes, including, but not limited to, excise, sales, use, property or transportation taxes related to the sale or use of the products, now or hereafter imposed, together with all penalties and expenses. Purchaser shall be responsible for collecting and/or paying any and all such taxes, whether or not they are stated in any invoice for the Products. Unless otherwise specified herein, all prices are exclusive of inland transportation, freight, insurance and other costs and expenses relating to the shipment of the Products from the F.O.B. point to Purchaser’s facility. Any prepayment by Seller of freight insurance and other costs shall be for the account of Purchaser and shall be repaid to Seller. -
PAYMENT TERMS
Payment terms are as follows: New Grind Inc. Machines – Payment prior to delivery.
All past due accounts are subject to a late payment fee of 1.5% per month or a maximum allowed by law if different, along with the expenses incidental to collection including reasonable attorney’s fees and costs.
Seller reserves the right to hold shipments against past due accounts.
*Seller reserves the right to alter payment terms. -
FREIGHT TERMS
All shipments will be made F.O.B. shipping point as designated in these Terms and Conditions, and title shall pass at the F.O.B. point. Delivery to the initial common carrier shall constitute delivery to the Purchaser. Any claims for loss or damage during shipment are to be filed with carrier by the Purchaser.
Seller will not assume responsibility for the performance of the carrier. Backorders will be shipped in the most practical fashion with charges consistent with our freight policy established with the original order.
UPS, FED EX, MAIL or shipments by other couriers are subject to the same terms and conditions as outlined in paragraph #3 ”Freight Terms”. -
DELIVERY, DAMAGES, SHORTAGES
Seller shall use reasonable efforts to attempt to cause the Products to be delivered as provided for in these Terms & Conditions. Delivery to the initial common carrier shall constitute the delivery to the Purchaser. Sellers responsibility, in so far as transportation risks are concerned ceases upon the delivery of the Products in good condition to such carrier at the F.O.B. point and all the Products shall be shipped at the Purchaser’s risk. Seller shall not be responsible or liable for any loss of income and/or profits, or incidental, special, consequential damages resulting from Seller’s delayed performance in shipment and delivery. -
RETURN OF DEFECTIVE PRODUCTS
Defective or failed material shall be held at the Purchaser’s premises until authorization has been granted by Seller to return or dispose of Products. Products that are to be returned for final inspection must be returned Freight Prepaid in the most economical way. Credit will be issued for material found to be defective upon Seller’s inspection based on prices at time of purchase. -
PRODUCTS ORDERED IN ERROR
Products may be returned, provided that claim is made, and Seller is notified within 7 days of receipt of Products, and the Products are in original buyer’s possession not more than 30 days prior to return, subject to Seller’s approval. If Products are accepted for return, they must be Freight Prepaid and buyer will be charged a minimum of 15% restocking charge, plus a charge back for outbound freight charges if the original order was shipped prepaid. Returns are not accepted for any Products that are specifically manufactured to meet the buyer’s requirement of either specifications or quantity.
Rhino RS150 Agreements
These Terms and Conditions constitute the entire agreement between Seller and
Purchaser as it relates to terms and conditions of sale and supersedes any and
all prior oral or written agreements, correspondence, quotations or
understandings heretofore in force between the parties relating to the subject
matter hereof.
There are no agreements between Seller and Purchaser with respect to the
Product herein except those specifically set forth in and made part of these
terms and conditions. Any additional terms, conditions and/or prices are
rejected by Seller. These terms and conditions may be modified, cancelled or
rescinded only by a written agreement of both parties executed by their duly
authorized agents.
NewGrind Inc.
103B- 81 Golden Drive, Coquitlam BC, CANADA V3K 6R2
Telephone: 1-888-467-0242
sales@newgrind.com
www.newgrind.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>