ALDORR 12000 BTU Mobile Smart Air Conditioner With Wifi User Manual
- June 13, 2024
- ALDORR
Table of Contents
- SAFETY INSTRUCTIONS
- FEATURES
- PARTS LIST
- INSTALLATION
- IMPORTANT SAFEGUARDS
- OPERATION
- REMOTE CONTROL
- MULTI PROTECTIVE FUNCTIONS
- EMPTYING THE INTERNAL WATER TANK
- CLEANING AND MAINTENANCE
- TROUBLESHOOTING
- ERROR CODES
- APPENDIX
- TECHNICAL DATA
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
12000 BTU Mobile Smart Air Conditioner With Wifi
User Manual 10000 BTU portable Air Conditioner
SAFETY INSTRUCTIONS
Important!
- Carefully read the instructions before operating the unit
- This appliance is for indoor use only.
- Rating: This unit must be only connected to a 220-240 V / 50 Hz earthed outlet.
- Installation must be in accordance with regulations of the country where the unit is used.
- lf you are in any doubt about the suitability of your electrical supply have it checked and, if necessary, modified by a qualified electrician.
- This air conditioner has been tested and is safe to use. However, as with any electrical appliance – use it with care.
- Disconnect the power from the appliance before dismantling, assembling or cleaning.
- Avoid touching any moving parts of the appliance.
- Never insert fingers, pencils or any other objects though the guard
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities. It is also not intended for use by those with a lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.
- Do not leave children unsupervised with this appliance.
- Do not clean the unit by spraying it or immersing it in water.
- Never connect the unit to an electrical outlet using an extension cord. If an outlet is not available, one should be installed by a qualified electrician.
- Never operate this appliance if the cord or plug is damaged. Ensure the power cord is not stretched or exposed to sharp objects/edges.
- A damaged supply cord should be replaced by the manufacturer or a qualified electrician in order to avoid a hazard.
- Any service other than regular cleaning or filter replacement should be performed by an authorised service representative. Failure to comply could result in a voided warranty.
- Do not use the appliance for any purpose other than its intended use.
- The air conditioner unit must always be stored and transported upright, otherwise irreparable damage may be caused to the compressor; if in doubt we suggest walting at least 24 hours before starting the unit.
- Avoid restarting the air conditioning unit unless 3 minutes have passed since being turned off. This prevents damage to the compressor.
- Never use the mains plug as a switch to start and turn off the air conditioning unit. Use the provided ON/OFF button located on the control panel.
- Always place the unit on a dry and stable surface. *The appliance should not be installed in laundry or wet rooms.
- The appliance must be placed in a room without sources of ignition (for example: open flames, an operating gas appliance or an operating electric heater).
- R290 refrigerant gas complies with European environmental directives.
- R290 has a low GWP (Global Warming Potential) of 3.
- The air conditioners contain around 240 g of R290 refrigerant gas.
- Do not use or store in an unventilated space with an area smaller than 11.5 m? per unit.
- The room must be such as to prevent stagnation of possible leaks of refrigerant gas as there could be a danger of fire or explosion should the refrigerant come into contact with electric heaters, stoves or other sources of ignition.
- Refrigerant gas may be odourless.
- Do not use the product and contact the retailer for advice, if damage has occurred to the unit which may have compromised the refrigerant system.
- Any repairs or maintenance must only be carried out on the unit by a suitably qualified engineer. Before opening and servicing the unit the authorised engineer must be in possession of a copy of the manufacturer’s service manual and must follow the safety information contained within it to ensure all hazards are minimized.
- The refrigerant system should not be perforated or punctured.
Energy Saving and Unit Safety Protection Tips
- Do not cover or restrict the airflow from the outlet or inlet grills.
- For maximum performance the minimum distance from a wall or objects should be 50cm.
- Keep the filters clean. Under normal conditions, filters should only need cleaning once every three weeks (approximately). Since the filters remove airborne particles, more frequent cleaning maybe necessary, depending on the air quality.
- For the initial start-up set the fan speed to maximum and the thermostat to 5 degrees lower than the current temperature. After, set the fan switch to low and set the thermostat to your desired setting.
- To protect the unit, we recommend not using the cooling function when the ambient temperature is higher than 38°C.
FEATURES
- 3in1 Cooling, Fan, Dehumidifier. The $F12000 is great for Rooms up to 28 m?,
- 2speed fan: Balancing quiet operation with performance.
- 24 Hours Start / Stop Timer.
- Digital Thermostat.
- Remote Control.
- Auto-Restart to retain the settings in the event of power failure.
- Castors for Enhanced Portability.
PARTS LIST
INSTALLATION
WARNING: Before using this unit, please keep it upright for at least 3-4
hours.
This unit can easily be moved from one room to another. While moving the unit
please note that it must
always be kept upright and then placed on an even surface.
-
Attach the fishtail connector to the end of the hose, by extending the end and twisting until firmly attached (At least 3 full rotations).
-
Attach the connector on the opposite end of the pipe to the exhaust outlet on the rear of the appliance by putting into position and twisting to lock in place.
-
Make sure the unit is upright and there are no obstructions to the air inlets and outlet grills.
INSTALLATION OF WINDOW KIT
The window kit (slide bar and fishtail) can be used with sliding windows and
doors. For other types of window, the fishtail should be used on its own.
-
Partially open the window and place the extended slide bar in position before closing the window onto it.
-
Fix the fishtail adaptor into the ~ opening on the slide bar
-
Fix the exhaust connector on the opposite end of the exhaust hose to the exhaust outlet on the rear of the air conditioner.
NOTES:
- The window kit is only designed to be installed with sliding or sash windows or doors. The window kit is not designed or to be used with any other style of windows.
- The fish tail adaptor can be used without the slide bar with most windows / doors.
- When using the air conditioner ensure that the opening left around the fishtail is as small as possible as the cooling will be less efficient.
- The best form of installation is through a wall duct. By properly venting you expel hot air from your room while efficiently cooling it.
- Your air conditioner should be used without the vent pipe in dry mode. When using dry mode ensure that an external water tank is used, monitored and regularly emptied before overflowing. Permanent plumbing can be also installed for dry mode or an external uplift water pump can be set up for unattended use.
IMPORTANT SAFEGUARDS
The length of the soft hose extends from approximately 30 cm to 180 cm. If
hose is extended above this length, the unit may malfunction which can
invalidate the warranty. The outlet vent must be well ventilated and not
obstructed as this will cause the unit to overheat. Keep the hose as straight
and short as possible and avoid bending the air hose by more than 30 degrees
in order to maintain the performance of the unit. Excessive bends in the hose
may prevent the unit from expelling the hot air, which can lead to internal
damage which would invalidate the warranty.
OPERATION
| Press the POWER button to turn the unit ON or OFF.
---|---
| Press the MODE button to cycle between the 3 modes, the indicator for the
selected mode will be illuminated.
COOL: The room is cooled with the cold air expelled through the front air
outlet while hot air is expelled through the vent pipe. The desired room
temperature can be set between 16 and 32 degrees using the + and — buttons,
and the fan speed can be changed using the SPEED button. FAN: The fan speed
can be changed pressing the SPEED button.
AUTO: An intelligent cooling mode where the fan speed is automatically
adjusted based on the amount of cooling required. Attempts to change the fan
speed will move the unit into COOL mode.
| Repeatedly press the SPEED button to cycle through the two fan speeds. Each
time the SPEED button is pressed, the indicator will change to show the
currently selected speed. The fan speed can be changed between Low and High.
The fan speed cannot be changed in DRY mode.
| The timer functions cannot be combined or repeated.
POWER ON TIMER
With the appliance in standby, press the TIMER button to set the power-on
timer. Use the + and – buttons to adjust the duration of the timer (1 to 24
hours). The Timer indicator will turn on and the unit will start after the
selected number of hours.
POWER OFF TIMER
With the appliance running with the desired settings, press the TIMER button
to set the power-off timer. Use the + and – buttons to adjust the duration of
the timer (1 to 24 hours). The timer indicator will illuminate and the unit
will stop after selected number of hours.
| Used to adjust temperature in COOL mode and to set the duration of the
TIMER. The buttons are not used in FAN or DRY modes. Press both buttons
together to change between displaying the temperature in Celsius and
Fahrenheit. Pressing the + – key simultaneously in each mode can switch
between Celsius and Fahrenheit
| DRY (DEHUMIDIFY)
The unit should be operated without the vent hose and with the unit set up for
continuous drainage to remove moisture from the air. The unit will operate at
low fan speed.
| Press this button to enable the swing function. When the SWING button is
pressed again the ) louvres will stop in their current position. Do not
attempt to adjust the angle of the blades manually.
REMOTE CONTROL
POWER | Press to turn the unit on or off. |
---|---|
TEMP – | Press to decrease the desired temperature or timer duration. |
TEMP + | Press to increase the desired temperature or timer duration. |
SPEED | Press to change between the two fan speeds. |
SLEEP | Press the sleep button to enter sleep mode. |
MODE | Press to change between Auto, Cool and Fan modes. |
NOTE: The design of the remote may vary from the diagram, due to continuous product improvement.
MULTI PROTECTIVE FUNCTIONS
FROST PROTECTION
In COOL, DRY or AUTO modes, if the temperature of the exhaust is too low, the
machine will automatically stop operating until the temperature has risen.
OVERFLOW PROTECTION
When the water in the internal water tank exceeds the warning level, the
machine will stop operating and sound an alarm with the LCD display showing
“Er. To resume operation, empty the internal water tank. After the water is
emptied, the machine will automatically return to the original state.
AUTO-DEFROST
The machine has automatic defrosting function. If during operation the
temperature of the internal coils drops too low, the unit will enter auto
defrost and the heating symbol will flash on the control panel.
AUTOMATIC THERMAL PROTECTION
To protect the service life of the machine, the machine has automatic thermal
protection. If the temperature within the unit is outside of the specified
range, the compressor and the lower motor will stop operation. The appliance
will automatically return to normal operation after the temperature of the
machine recovers.
COMPRESSOR PROTECTION
To prevent damage to the compressor there is a 3-minute delay start protection
function.
EMPTYING THE INTERNAL WATER TANK
MANUAL DRAINAGE:
When the internal water tank is full the unit will stop working.
Shut off the unit and unplug. Try not to move the model abruptly as this may
cause the water in the internal tank to spill out.
Place a tray under the lower water plug or place the unit in a drainage area.
Unscrew the drain plug cap and remove the rubber stopper – water will drain
from the internal tank. Put the rubber stopper back and screw the drain plug
cap back into place.
CONTINUOUS DRAINAGE:
Unscrew the drain plug cap and remove the rubber stopper.
Connect a water pipe to the upper water outlet.
You can plumb this pipe into
your current plumbing system, lead it outside and use gravity fall or use a
water pump.
NOTE: This model has a self-evaporative function, which reduces the need
to empty the water tank. If the unit is vented correctly most of the water is
reused to cool the condenser coils and any excess is evaporated. Please do not
use continuous drainage if you intend to use the self-evaporating facility.
CLEANING AND MAINTENANCE
PLEASE TURN OFF THE UNIT AND UNPLUG FROM THE MAINS BEFORE CLEANING OR
PERFORMING ANY MAINTENANCE
CLEAN THE SURFACE
Clean the surface of the machine with a wet soft cloth. Do not use chemicals,
such as benzene, alcohol, gasoline, etc; otherwise, as this may cause damage
to the surface and or the internal workings of the machine
AIR FILTER CLEANING
If the filter screen is clogged with dust, the effectiveness of the air
conditioner is reduced. The filter screen should be cleaned once every two
weeks or as often as necessarily in your environment.
CLEAN THE UPPER FILTER
SCREEN FRAME
Slide out the fitter screen frames from the unit. If there are screws holding
the filter in place these should be removed.
The evaporator filter screen can be cleaned in warm water with neutral
detergent (about 40°C /104°F). It must be rinsed clean and dried in the shade
before reinstalling in the unit.
CLEAN THE LOWER FILTER SCREEN FRAME
Hold the handle of the air inlet filter screen frame, and pull it outward
gently to remove it.
Put the filter screen into warm water with neutral detergent (about 40°C / 104
°F). It must be rinsed clean and dried in the shade before reinstalling in the
unit.
END OF SEASON MAINTENANCE
- Remove the rubber stopper from the drainage hole and empty the internal tank. You can also drain the water by leaning the unit.
- Then switch the unit to low fan mode.
- Keep the unit in this mode for half day – until the conduit is dried. Doing this helps to keep the inside of the unit dry and prevents mould from developing
- Turn off the unit and pull out the plug.
- Replace the rubber stopper.
- Coil the wire and bind it together, then put it into the accessories space.
- Separate the air-exhaust pipe and store it safely.
- Cover the unit and keep it in a dry place.
- Take the batteries out of remote control and store or dispose of them safely. Keep all accessories with the unit ready for next season.
TROUBLESHOOTING
Do not repair or disassemble the air conditioning. Unqualified repair will invalidate the warranty and may lead to failure, causing injuries and property damage. Only use it as directed in this user manual and only perform operations advised here.
Problems | Reasons | Solutions |
---|
The air
conditioner does not work.| There is no electricity.| Turn it on after
connecting it to a socket with electricity.
The display shows “E4”.| Discharge the water inside.
The ambient temperature is too low or too high| Only use to use the machine
within temperature range of 735°C (44.95°F).
In cooling mode, the room temperature Is lower than the desired temperature.|
Change the desired temperature.
In dry mode, the ambient temperature is low.| The ambient temperature must be
above 16 °C. (60 °F).
The cooling effect is not good| There is direct sunlight.| Use curtains to
reduce the direct sun heat.
Doors or windows are open; there are a lot of people; or in cooling mode,
there are other sources of heat (e.g. fridges).| Close doors and windows;
increase air conditioning power.
The filter screen is dirty.| Clean or replace the filter screen.
The air inlet or outlet is blocked.| Clear obstructions; make sure venting is
correct as described in this user manual and hose Is not bent.
Loud Noise| The air conditioning is not placed on a flat surface.| Put the air
conditioning on a flat and hard place (to reduce noise).
Compressor does not work.| Ove rheat protection starts.| Wait for 3 minutes
until the temperature is lowered, and then restart the machine.
The remote
control does not work.| The distance between the machine and the remote
control is too far.| Let the remote control get close to the air conditioner,
and make sure that the remote control directly faces the receiver.
The remote control is not aligned with the receiver.
Batteries are dead.| Replace batteries.
Others| little No refrigerant or there is veryttle refrigerant.| Refer to
Service Centre (check leakage, wielding, vacuum pump, charge refrigerant
according to name plate).
Anti-freezing protection.| Waiting for defrosting.
Function will recover automatically. No user input needed.
High pressure protection.| After inside gas pressure comes down, it will
function normally. No user Input needed.
If problems not listed in the table occur or recommended solutions do not work, please contact the service centre.
ERROR CODES
CODE | CAUSE | SOLUTION |
---|---|---|
dH | Unit In dry mode. | Not a fault, no action required. |
E2 | Room temperature sensor error. | Room temperature is outside the |
operational range. Do not operate until the room is within the range required.
E4| Water full alarm.| Empty the water tank.
MODE LIGHT FLASHING| Cool / dry mode, the compressor has not started, the
mode light will flash. This Is normal.| The unit will start operation when the
protection period has finished (approx. 3 minutes).
APPENDIX
Disposal: Do not dispose this product as unsorted municipal waste. Collection of such waste must be handled separately as special treatment is necessary. Recycling facilities are now available for all customers at which you can deposit your old electrical products. Customers will be able to take any old electrical equipment to participating civic amenity sites run by their local councils. Please remember that this equipment will be further handled during the recycling process, so please be considerate when depositing your equipment. Please contact the local council for details of your local household waste recycling centres.
TECHNICAL DATA
Model | SF12000 |
---|---|
Cooling capacity: | 10,000 BTU |
Input power: | 1100 W |
Fan | AC motor with 2 fan speeds. |
Air flow volume: | 350 m’/h |
Input current: | 4.8 A |
Refrigerant: | R290/240g |
Sound power level: | 56 dB(A) |
Thermostat: | 16-32°C |
Maximum working pressure of
suction/exhaust side:| 1.0/3.5 MPa
Maximum Allowable Pressure| 3.5 Mpa
Power Supply:| AC 230V/50 Hz
Net Weight:| 25 kg
Dimension(LDH):| 468 x 498 x 797 mm
Unit must be vented outside when in Air Cooling mode. For the purposes of EU regulation EN12102 this is a local air conditioner and produces less than 65dB(A) sound energy.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>