Xibu C1/C2 L1/L2 H1/H2 SPL Washrooms sense TAP PROFI Installation Guide

June 13, 2024
Xibu

Xibu C1/C2 L1/L2 H1/H2 SPL Washrooms sense TAP PROFI Installation Guide
SPL Washrooms sense TAP PROFI

Assembly Instruction

chrom (Typ 1100 B/N, 1110 B/N, 1120 B/N)
matt (Typ 1200 B/N, 1210B/N, 1220B/N)
Assembly Instruction
inox (Typ 1400 B/N, 1410 B/N, 1420 B/N)
Assembly Instruction
C1/L1/HA
Assembly Instruction
1 = Batterie/battery
6V Lithium
CR-P2, DL 223A

Cc1/L2
Assembly Instruction
C2/L2/H2
Assembly Instruction
1 = Adapter
AC230V/6V
Assembly Instruction

Installation Instructions

  1. Assembly Instruction
  2. Assembly Instruction

Assembly Instruction

  • ci/c2
    Assembly Instruction  

  • L1/l2
    Assembly Instruction

  • H1/H2
    Assembly Instruction

  • C1/LA/H1
    Assembly Instruction

  • C2/L2/H2
    Assembly Instruction
    Assembly Instruction

Operation:

Automatic range adjustment

  • **** Before electrical connection or insertion of batteries pay attention that the corner valves are open.
    Do not hold your hands in front of the armature until the adjustment of the sensor range! Automatic

  • 10-15 sec. after electronic operation water will run and the range of the sensor will adjust automatically to the distance of the water jet.
    Function test

  • Hold your hands towards the area of the water jet/drain.

    • Water is running: OK
    • Water is not running: see chart below.

Important notice:

  • Follow standards, guidelines and regulations of the country and the local water works!
  • Installation only in frost-proof rooms!
  • Installation only by skilled expert staff.
Error Reason Solution
Water
  • Corner
  • Main water tap closed
  • Electrical
  • Sensor
  • Magnet

|

  • Open corner valves
  • Open main water tap
  • ctivate electrical supply
  • Contact/call service
  • Unfasten magnet valve and blow

Water Is only not running low|

  • Filter screens contaminated
  • Aerator contaminated/calcified

|

  • Clean filter screens
  • Clean/decalcify aerato

Water is running permanently|

  • Magnet valve broken

|

  • Close comer valves and contact/call service
  • Unfasten magnet valve and blow out (clean)

ED display (sensor) flashes|

  • Empty battery

|

  • Close comer valves and | IMITFN | change battery