DCC Electric DCC-11 Gen 2 Electric Vehicle Energy Management System Instruction Manual
- June 13, 2024
- DCC Electric
Table of Contents
DCC-11
Electric Vehicle Energy
Management System (EVEMS)
INSTALLATION MANUAL
MODELS
DCC-11-30A, DCC-11-40A, DCC-11-50A, DCC-11-60A
DCC-11 Gen 2 Electric Vehicle Energy Management System
MAIN POWER SUPPLY
120/240-208V, Single Phase
150A – 200A
APPROVED MARKET
North America
Read and save these instructions
ABOUT THIS MANUAL
ERRORS AND INACURACIES
For any inaccuracy or omission, or to forward any general comments or
suggestions concerning the quality of this manual, please send an email to
info@dccelectric.com.
COPYRIGHTS AND TRADE NAMES
All information’s in this manual are subject to copyright protection and
other intellectual property protection of THERMOLEC LTÉE. / RECHARGE
VÉHICULE ÉLECTRIQUE and its licensors. This installation manual cannot be
modified, reproduced or copied without a prior written authorisation from
THERMOLEC LTÉE. / RECHARGE VÉHICULE ÉLECTRIQUE and its licensors.
Additional information’s are available on request. The following logos are
trade names or trademarks of THERMOLEC LTÉE. / RECHARGE VÉHICULE ÉLECTRIQUE
in the United States and in Canada.All other trade names mentioned in this
document are the property of their respective owners and their uses in this
manual does not means a sponsorship or approval of the product. The use of any
trade name shown in this document is strictly forbidden.
In this document, the terms DCC – EVEMS and DCC are equivalent.
SAFETY INFORMATION
This document describes important safety instructions which must be followed
during installation, maintenance and application of the DCC – Electric Vehicle
Energy Management System (EVEMS).
Warning
Read all instructions prior using this product.
Always disconnect the DCC – EVEMS power supply before any works.
Use only the DCC – EVEMS by following the technical specifications indicated
in this installation manual.
Do not install the DCC – EVEMS nearby inflammable materials, explosives or
fuels, chemical products and vapors.
Never spray the DCC – EVEMS with water or any other liquids.
Stop using the DCC – EVEMS immediately if defective, cracked, broken or
damaged.
Never try to modify, repair or dismantle the DCC – EVEMS. Please contact the
manufacturer for any malfunction.
Never insert a sharp object inside the DCC – EVEMS at the risk of causing
damages to the components.
Any improper use of the DCC – EVEMS could result in serious injuries which may
cause death.
For a vertical installation on a wall, refer to the information’s on the
enclosure for the choice of mounting position.
Precautions
Any improper use of the DCC – EVEMS can cause damages and premature wear of
the components, which voids the warranty.
Never use the DCC – EVEMS above or below the temperature range of -22 °F to
113 °F (-30 °C to 45 °C).
Only store the DCC – EVEMS above or below the temperature range of -4 °F to
158 °F (-20 °C to 70 °C).
The installation of the DCC – EVEMS must be done in accordance with the latest
electrical code requirements.
Notes
It is recommended to schedule the charging of the vehicle during hours of low
electrical consumption to minimize interruptions to the electric charging
station.
Always check that the DCC – EVEMS is adequately fixed to the wall or ceiling
or in a location to avoid any damages.
Even if this product is advertised for EV chargers, it can be installed with
other types of load.
It is the installer’s responsibility to make sure that the electric power
source is adequate for the use of the DCC – EVEMS.
Do not use any cleaning solvents to clean the DCC – EVEMS.
Limited warranty
-
THERMOLEC LTÉE. warrants the integrated controls against any defects for a period of one year from the shipping date. The warranty is limited to the equipment and components supplier by THERMOLEC LTÉE.
-
In case of incorrect installation, inappropriate use or repairs done by unauthorized personnel by THERMOLEC LTÉE., the warranty will be automati- cally void.
-
THERMOLEC LTÉE. undertakes to repair or replace, at site or at the manufacturing location, at his option, the defective material only after an evaluation made by its representative.
-
THERMOLEC LTÉE. will not be held liable for damages or delays and will not be required to pay transport cost of the EVEMS said to be defective.
-
THERMOLEC LTÉE. shall not be liable for any indirect damages or delays caused by faulty workmanship or materials.
No indemnity will be paid for repairs, replacements or modifications without a prior written consent supplied by THERMOLEC LTÉE. -
Any control device or accessory supplied with the DCC – EVEMS to be installed or connected remotely from the EVEMS will be guaranteed by the manufacturer only under the special conditions mentioned in paragraph 5.
-
The components supplied for repairs are guaranteed for the remaining of the warranty on the original product or 90 days. The longest period will prevail.
-
All repairs made at the THERMOLEC LTÉE. plant are guaranteed for 30 days from the date of repairs.
SPECIFICATIONS
The DCC – Electric Vehicle Energy Management System (EVEMS) is a safety device with programmable controller that can protect an electrical distribution circuit in relation with its main breaker. It will prevent overloading the electrical distribution circuit by turning off momentarily the power to the charging station when the demand exceeds 80% of the main breaker rating.
Voltage and wiring | 240/208V AC single phase: L1, L2, Neutral, Ground. |
---|---|
Terminals size | up to 2/0 (CU/AL) |
Frequency | 50 to 60 Hz |
Operation temperature | -22°F to 113°F (-30°C to 45°C) |
Dimensions* (H” x W” x D”) | 16″ x 16″ x 8″ |
Total weight* | 23 lb (10,43 kg) |
*Approximative and can change without notice.
CHARACTERISTICS
CONDITIONS FOR APPLICATION
The DCC-11 is an Energy Management System specially designed to allow the
connection of an EV Charger to be connected to a power source without
affecting load calculation.
INSTALLATIONS TYPES
Group installation, Wall installation, Ceiling installation
MAIN POWER SUPPLY (CB)
The DCC – Electric Vehicle Energy Management System (EVEMS) can be powered by
a 240/208V AC single phase source.
The following options are offered by each DCC model:
Models | Breaker | Main power supply |
---|---|---|
EV charger | 150A | 200A |
DCC-11-30A | 30A | |
DCC-11-40A | 40A | |
DCC-11-50A | 50A | |
DCC-11-60A | 60A |
SECONDARY LOAD SUPPLY (EVC)
The DCC – EVEMS will provide power to a charging station through a 30A,
40A, 50A or 60A 240/208V AC circuit breaker, L1, L2 and ground. The DCC is
equipped with a Square D circuit breaker (QU0230, QUO240, QU0250 or QUO0260).
TRIP PERCENTAGE (TP)
The DCC – EVEMS is factory set to turn off the charging station if the
total consumption of a service exceeds 80%. For other configurations, please
contact the factory.
POWER OUTAGE
In the event of a power outage, the DCC – EVEMS automatically restore the
power supply to the vehicle charging station when power returns.
RECOVERY TIME (RT)
Following a power cut to the electric vehicle supply equipment (EVSE), a 15
minutes delay is initiated to monitor the total consumption of the electrical
power system. Power to the vehicle will then be restored if the total load
consumption is lower than 80% of the main circuit breaker rating during a
period exceeding the 15 minutes’ recovery time.
TYPICAL INSTALLATION
DCC INSTALLATION
STEP 1: CHECK THE PACKAGE CONTENTS INSTALLATION VIDEO
To access our installation video, visit our website
www.dccelectric.com
STEP 2: PREPARATIONS FOR INSTALLATION
-
Disconnect the main power
-
Select the DCC intended location.
The DCC can be mounted:
– on a ceiling
– on a wall
NOTE: The DCC controller must be mounted so that the nameplate remains visible at all times.
Do not install the DCC:
– Outdoor
– In a location with high level of risk
– Nearby inflammable materials, explosives or fuels, chemical products and vapors. -
Before installation, check the DCC mounting position.
Wall installation
Refer to the information on the enclosure to insure proper installation.
Ceiling installation
The installation may be done in any direction.
WARNING
Warranty automatically void if the DCC is installed incorrectly.
STEP 3: INSTALLATION
Ceiling installation
- Remove the 4 cover screws.
- Fix the ceiling mounting support on the DCC.
- Lift the DCC using the ceiling mounting support.
- Position the DCC at the intended location.
- Fix the DCC with the anchors for the type of surface.
- Check that the DCC is adequately fixed to the wall or ceiling.
- Remove the ceiling mounting support.
Wall installation
- Remove the 4 cover screws.
- Position the DCC at the intended location.
- Ensure that the mounting is according with the information’s on the enclosure.
- Fix the DCC with the anchors provided for the type of surface.
- Check that the DCC is adequately fixed to the wall or ceiling.
STEP 4: CONDUCTOR CONNEXIONS
Consult the diagram on the next page for all details on the cable connections
configuration. This diagram is also found under the DCC cover.
STEP 5:
DIP SWITCH PROGRAMMING FOR MAIN POWER SUPPLY (CB)
- Identify the set-up section on the DCC.
- Set up the section as per the layout corresponding to the main power supply (CB):
STEP 6: START-UP
DCC power supply
- Supply electrical power to the DCC.
- Wait ten (10) seconds.
- Check if the relay is switched on.
- Check the pilot light:
GREEN at all time: compliant installation, go to the next step.
RED: refer to the Lights code section.
Charging station power supply
- Put the circuit breaker in the ON position.
- Check if the electric vehicle supply equipment (EVSE) is powered:
EVSE powered: go to the next step.
EVSE not energized: check the charging station connections.
LEGEND
R | POWER RELAY |
---|---|
DCC | ELECTRONIC CONTROLLER |
CB | CIRCUIT BREAKER |
T | TRANSFORMER |
CT | CURRENT TRANSFORMER |
IMPORTANT
Wire in accordance with local and National Electrical codes.
Read instructions carefully before wiring and operating.
CONFIGURATION DIAGRAMS Main Circuit Breaker
(Amps)![DCC Electric DCC 11 Gen 2 Electric Vehicle Energy Management System
- Main Circuit Breaker](https://manuals.plus/wp-content/uploads/2023/09/DCC- Electric-DCC-11-Gen-2-Electric-Vehicle-Energy-Management-System-Main-Circuit- Breaker.jpg)
Models | Main power supply |
---|---|
150A | 200A |
DCC-11-30A | |
DCC-11-40A | |
DCC-11-50A | |
DCC-11-60A | |
Trip Percentage (%) Reintegration Time (Minutes)
EV Charger (Breaker) Trip Delay: 15 seconds (Default)
TITLE
DCC-11 CONTROLLER GEN 3
BOITIER DE CONTROLE DCC-11 GEN 3
DRAWING NO. | DCC-11 CONTROLLER |
---|
DATE
05-18-2021| PER| V1
STEP 7: SECURE AND RE-ENERGIZE
Secure
- Turn off the power on the DCC.
- Put the cover back.
Re-energize
- Supply electrical power to the DCC.
STEP 8: IDENTIFICATION
- Register all the information of the charging station owner (address and parking space) in the space provided on the cover.
- Register all configuration settings of the main power supply (essential load) in the space provided on the cover.
- Register all configuration settings of the charging station in the space provided on the cover.
APPLICATION
Electric vehicle recovery time
Following a power cut to the electric vehicle supply equipment (EVSE), a 15
minutes delay is initiated to monitor the total consumption of the electrical
system. Power to the vehicle will then be restored if the total load
consumption is lower than 80% of the main circuit breaker rating.
Electric vehicle charging time
It is recommended to schedule the charging vehicle program during hours of low
electrical consumption to minimize interruptions to the electric charging
station.
MAINTENANCE
Do not use any cleaning solvents to clean the DCC.
LIGHTS CODE The charging station is energized. The charging station is
energized. The total load exceeds 80%. If the loads exceed 80% for a
predetermined period, the charging station will be de-energized. The charging
station is not energized. The total loads exceed 80%. The resumption time will
start when the total load is lower than 80%. The charging station is not
energized. The total load is lower than 80% and the recovery time is in
progress. Each flash mean two (2) minutes before the resumption of power to
the charging station. (ex: 3 flashes = 6 minutes before power to the charging
station). During that period, if the total load exceeds 80%, the recovery time
will restart from the beginning. Malfunction:
- Check all connections and voltage.
- Check the DIP switch configuration settings.
- Check if the current transformers (CT) are properly connected and interlocked.
- Check if the connection for the current transformers are properly connected to the PCB electronics.
- If the problem persists, send pictures of the installation at support@dccelectric.com and then call 1 833-717-1355.
No power. Check the power source.
References
- DCC Electric Vehicle (EV) Charging for Condos or Full Panel Homes
- DCC Électrique - Contrôleur de charge pour véhicule électrique
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>