AJAX Systems FireProtect Wireless Indoor Fire Detector User Manual
- June 12, 2024
- Ajax Systems
Table of Contents
- Systems Fire Protect Wireless Indoor Fire Detector
- Functional Elements
- Operating Principle
- States
- Interconnected FireProtect Alarms Setup
- Indication
- Performance testing
- Detector Testing
- Installation
- Maintenance and Battery Replacement
- Tech Specs
- Compliance with standards
- Warranty
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Fire Protect / Fire Protect Plus User Manual
Updated December 7, 2021
Systems Fire Protect Wireless Indoor Fire Detector
Fire Protect (Fire Protect Plus) is a wireless indoor e detector with an in-
built buzzer and a battery, ensuring up to 4 years of autonomous operation.
Fire Protect can detect smoke and rapid temperature increase.
Aside from these functions, Fire Protect Plus additionally can alert of
dangerous CO level. Both detectors can function independently from the hub.
Connecting to the Ajax security system via a secured radio protocol, Fire
Protect (Fire Protect Plus) communicates with the at a distance of up to
Jeweler hub 1,300 m in line of sight.
The detector can be a part of third-party security systems, connecting to them
via the Ajax quart Bridge Ajao Bridge Plus or integration module.
Buy e detector with carbon monoxide sensor Fire Protect Plus
The detector is set up via the Ajax apps for iOS, Android, macOS, and Windows.
The system nutrients through push note calls (if activated).
The Ajax security system can be connected to a central monitoring station of a
security company.
Buy e detector Fire Protect
Functional Elements
- Siren hole
- Light indicator (acts as the sensor and Test button)
- Smoke chamber hole with the temperature detector behind the net
- Smart Bracket attachment panel
- Power button
- Tamper button
- QR code
Operating Principle
When smoke penetrates the detector chamber, it distorts infrared light between
the emitter and photoelectric receiver. This distortion triggers a smoke
alarm.
When the temperature exceeds 60°С or rises by 30°С during 30 minutes (not
necessary to reach 60°С), the detector registers temperature increase, which
triggers a e alarm.
The life span of the Fire Protect Plus detector lasts up to 7 years (up to 10
years for the ). In the event of a detector failure, you will receive a
corresponding Fire Protect comprehensive diagnostics notion be replaced or
submitted for
In case of alarm, the detector activates the built-in buzzer (the siren sound
can be heard from afar) and blinks with the light indicator. When connected to
a security system, both the user and the security company are notialarm.
Fire Protect Plus reacts to carbon monoxide long before the oms of poisoning
appear. It is triggered:
- Not earlier than 120 minutes at a carbon monoxide concentration of 0.003% (30 ppm).
- 60 to 89 minutes at a carbon monoxide concentration of 0.005% (50 ppm).
- 10 to 39 minutes at a concentration of 0.01% (100 ppm).
- Up to 3 minutes at a concentration exceeding 0.03% (300 ppm).
Loss of consciousness is possible at a CO concentration of 0.1% lasting over 2
hours!
The detector stops notifying about the dangerous level of carbon monoxide when
the concentration drops to 40 ppm (0.004%) within one minute.
The siren of the device can be turned off using three ways:
- By pressing the Ajax logo on the device lid (there is a touch button under the logo).
- Through the Ajax app. In case of e alarm, you will see a pop-up message in Ajax app suggesting to turn off the built-in sirens.
- Using the
Key Pad Key Pad Plus / (if Interconnected Fire Protect Alarms feature is enabled). To turn off the built-in sirens in case of e alarm, press the “*” button on the Key Pad/Key Pad Plus.
Please note that for this to work you need to priory select Mute
Interconnected Fire Alarm command for this button in the Key Pad/Key Pad Plus
settings.
If smoke and/or temperature levels do not restore to normal values, in 10
minutes, the Fire Protect/Fire Protect Plus turns on the siren again.
Connecting the Detector to the Ajax Security System
Connecting to the hub
Before starting connection:
- Following the hub user guide, install the Ajax app . Create the account, add the hub, and create at least one room.
- Switch on the hub and check the internet connection (via Ethernet cable and/or GSM network).
- Make sure that the hub is disarmed and does not update by checking its status in the Ajax app.
Only users with administrator rights can add the device to the hub
Pairing the detector with hub:
- Select Add Device in the Ajax app.
- Name the device, scan or type the QR Code (located on the detector body and packaging), and select the location room.
- Tap Add — the countdown will start.
- Switch on the device.
To make sure that the detector is on, press the on/off button — the logo will
light up red for a second.
For detection and pairing to occur, the detector should be located within the
coverage area of the wireless network of the hub (at a single protected
object).
The connection request is transmitted for a short time: at the moment of
switching on the device.
If pairing with the hub fails, the detector operates autonomously; switch off
the detector for 5 seconds and retry.
The detector connected to the hub is displayed in the list of devices in the
app.
The update of the detector status in the list depends on the device inquiry
time set in the hub settings (the default value is 36 seconds).
Connecting to Third Party Security Systems
To connect the detector to a third party security central unit using the or
Ajax quart Bridge Ajao Bridge Plus integration module, follow the
recommendations in the manual of the respective device.
The smoke detector always operates in the active mode. When connecting Fire
Protect to third party security systems, it is appropriate to place it in a
permanently active protection zone.
States
- Devices
- Fire Protect | Fire Protect Plus
Parameter | State |
---|---|
Temperature | Temperature of the device. Measures on the device processor and |
changes gradually
Jeweller Signal Strength| Signal strength between the hub and the detector
Connection| Connection status between the hub and the device
Battery Charge| Battery level of the device. Two states available: ОК
Battery discharged
How battery charge is displayed in Ajax apps
Lid| The tamper state of the device — reacts to the detachment
---|---
ReX| Displays the status of using a radio signal range extender
Smoke| Shows if smoke is detected
Temperature Threshold Exceeded| The state of temperature threshold exceeded
alarm
Rapid Temperature Rise| The state of rapid temperature increase alarm
High CO Level (Fire Protect Plus only)| The state of dangerous CO level alarm
Backup Battery Charge| Backup battery level of the device
Smoke sensor| The state of the smoke detector
Smoke Sensor Dust Level| The dust level in the smoke chamber
Temporary Deactivation| Shows the status of the device: active, completely
disabled by the user, or only notifications about triggering of the device
tamper button are disabled
Firmware| Detector firmware version
Device ID| Device identifier
Interconnected FireProtect Alarms Setup
The function activates built-in sirens of all e detectors if at least one of
them is triggered. Sirens are activated within the hub–detector ping interval
according to the Jeweler settings.
To enable Interconnected Alarms:
-
Open the Devices tab in the Ajax app
-
Select a hub
-
Go to its Settings by pressing
-
Select the Service item
-
Go to the Fire detectors settings menu and activate the Interconnected Fire Protect Alarms option
Interconnected alarms are supported by Fire Protect and Fire Protect Plus detectors with e versions 3.42 and later. Please note that when you turn on the interconnected alarms, you cannot set the hub–detector ping interval (Jeweler settings) of more than 48 seconds. -
If necessary, set the Delay of Interconnected Alarms from 0 to 5 minutes (in 1-minute increments). The option allows you to postpone the interconnected alarm for a specie
When this option is inactive, the interconnected alarm is sent to all e detectors within a minute.
The function works as follows:
-
One of the Fire Protect/Fire Protect Plus detectors detects an alarm.
-
Delay of Interconnected Alarms starts.
-
The built-in siren of the e detector informs the alarm. Users receive note appropriate note are enabled). At the object, Ajax sirens are activated (if the corresponding settings are enabled).
-
An alarm convent is sent to the monitoring station and security system users, and the system starts the interconnected alarm for e detectors if:
• The interconnected alarm delay time has passed, and the triggered detector is still registering an alarm.• During the delay of the interconnected alarms, the triggered detector reports a different type of alarm (for example, the detector report the exceeding of the temperature threshold after a smoke alarm).To give more time to eliminate the cause of false triggering of the detector, the user can delay the propagation of the interconnected alarm for another 10 minutes:
• Through Ajax apps. • By pressing the Key Pad/Key Pad Plus function button (in the interconnected e alarm muting mode).
• By pressing the Button in the interconnected e alarm muting mode.
• By eliminating the cause of the alarm (e detectors at the facility no longer detect an alarm).
• By pressing the touch button of the triggered e detector.
If a triggered detector does not return to a normal state within 10 minutes after the user postponed the interconnected alarm, another e detector reports an alarm, or a triggered detector reports an alarm of another type (for example, temperature and smoke), the system will send an alarm connate interconnected alarm for e detectors. -
If necessary, activate the Ignore First Alarm option. This setting is recommended for premises with potential sources of false alarms. For example, if the device is installed in a place where dust or steam can get into the detector.
The option functions as follows:
- The detector reports a smoke alarm.
- The built-in 30-second timer of the detector starts.
- If after 30 seconds the detector still detects a threat, an alarm is sent to the hub.
Setting the Residential e alarm system
Residential e alarm system is an Ajax system feature that de device rights to
mute the interconnected alarms of e detectors.
If the feature is enabled, users can silence e alarms of triggered detectors
only in the groups to which they have access. And Button, Key Pad, Key Pad
Plus — the alarms only of those e detectors that are in the same group.
The feature is useful for objects consisting of several rooms and protected by
a single hub. For example, for multi-apartment complexes where each apartment
is a group with at least one e detector installed. In this case, users can
respond to the alarms of their groups without silencing the alarms of other
groups.
The feature is available for Hub Plus Hub 2, , and Hub 2 Plus OS Malevich 2.12
on and later versions.
Learn more
Indication
Event | Indication |
---|---|
Detector switching on | The logo lights up green for 1 second |
Detector switching off | The logo blinks red three times and the device |
switches off
Registration failed| The logo blinks green for a minute, then the device
switches to the autonomous mode
Smoke or temperature increase detected| The siren switches on, the logo lights
red during the fire/smoke alarm
Battery low| One short sound signal per 90 sec — main batteries low (CR2)
Two short sound signals per 90 sec — backup battery low (CR2032)
Three short sound signals per 90 sec — both batteries low
Performance testing
The Ajax security system allows conducting tests for checking the
functionality of connected devices.
The tests do not start straight away but within a period of 36 seconds when
using the standard settings. The test time start depends on the settings of
the detector scanning period (the paragraph on “Jeweler” settings in hub
settings).
Jeweler Signal Strength Test
Fire Protect Self Test
Attenuation Test
According to the requirements of EN50131 standard, the level of the radio
signal sent by wireless devices is decreased during the test mode.
Detector Testing
Before installing the detector, check the smoke sensor. To test it, switch on
the detector and press the sensor button (the logo center) for a few seconds –
the detector will test the smoke chamber with electronic simulation of smoke
generation and then will switch on the siren for 6 seconds.
You will receive the notiegarding the test result and detector status.
Installation
Selecting the Location
The location of the detector depends on its remoteness from the hub, and
obstacles hindering the radio signal transmission: walls,ge objects inside the
room.
The device developed only for indoor use.
If the signal level is low (one bar), we cannot guarantee the stable operation
of the detector. Take all possible measures to improve the quality of the
signal. At least, move the detector: even a 20 cm shift can signore the
quality of signal reception.
Check the Jeweler signal level at the installation location
If after moving the device still has a low or unstable signal strength, use a
radio signal range extender
Install the detector at the ceiling in the highest point where hot air and
smoke are concentrated in case of e.
If there are any beams at the ceiling, protruding by 30 or more centimeters
from the ceiling level, install the detector between every two beams.
How to install Fire Protect e detector correctly Where and how to install Fire
Protect Plus
Installation procedure
Before installing the detector, make sure that you have selected the optimal
location that follows the guidelines of this manual!
-
Fix the Smart Bracket panel on the ceiling using bundled screws. If you use any other attachment tools, make sure that they do not damage or deform the attachment panel.
Use double-side adhesive tape only for temporary attachment of the detector. The tape runs dry with time, which can cause falling, false triggering, and detector malfunction. -
Put the detector on the attachment panel by turning it clockwise on Smart Bracket. When the detector is ed in Smart Bracket, it blinks with LED, signaling that the tamper is closed.
If LED doesn’t blink after bracket, check the status of the tamper in the Ajax
app and then the
If someone detaches the detector from the surface or takes it off the
attachment panel, the security system notion.
Do not install the detector:
- outside the premises (outdoors);
- nearby any metal objects or mirrors causing attenuation or screening of the signal;
- at any places with fast air circulation (air fans, open windows or doors);
- closer than a meter to the cooking surface;
- inside premises with the temperature and humidity beyond the range of permissible limits;
- closer than 1 m to the hub.
Autonomous Use of the Detector
The detector can be used autonomously, without connecting to a security
system.
- Switch on the detector by pressing the on/off button for 3 seconds (the logo will light up green for 1 second) and conduct the smoke test.
- Select the optimal location of the detector following the recommendations in the second part of the section Selecting the location of this manual.
- Install the detector as described in the section Installation procedure.
In case of autonomous use, the detector notie/smoke with the siren sound and light of the logo. To switch off the siren, press the logo (there is a sensor button) or eliminate the cause of the actuated alarm.
Maintenance and Battery Replacement
Check the operational capability of the detector regularly. Clean the detector
body from dust, spider web, and other contaminants as they appear. Use soft
dry napkin suitable for tech equipment.
Do not use any substances containing alcohol, acetone, gasoline, and other
active solvents to clean the detector.
To a certain level, the detector ignores the dust in the smoke chamber. When
the chamber becomes too dusty, the detector notio clean it via the app (and
beeps every minute and a half). Such maintenance is compulsory for the
detector to operate correctly.
How to clean up the smoke chamber
Pre-installed batteries ensure up to 4 years of autonomous operation. If
the batteries are discharged, the security system sends the respective noti
and the detector signal with a sound every 90 seconds:
- if the main batteries are low — a single short signal;
- if the backup battery is low — two short signals;
- if both batteries are low — three short signals.
Keep new and used batteries away from children. Do not ingest battery,
Chemical Burn Hazard.
How long Ajax devices operate on batteries, and what affects this
Battery Replacement
Tech Specs
Smoke-sensitive element | Photoelectric sensor |
---|---|
Temperature sensitive element | Thermocouple |
Sound notiolume | 85 dB at a distance of 3 m |
Alarm threshold at the temperature | +59°С ±2°С |
Tamper protection | Yes |
Radio communication protocol | Jeweller |
Learn more
Radio frequency band| 866.0 – 866.5 MHz
868.0 – 868.6 MHz
868.7 – 869.2 MHz
905.0 – 926.5 MHz
915.85 – 926.5 MHz
921.0 – 922.0 MHz
Depends on the region of sale.
Compatibility| Operates independently or with all Ajax hubs radio signal range
extenders Oxbridge Plus quart Bridge
Maximum RF output power| Up to 20 mW
Radio signal modulation| GFSK
Radio signal range| Up to 1,300 m (any obstacles absent)
Learn more
Power supply| 2 × CR2 (main batteries), CR2032 (backup
battery), 3 V
Battery life| Up to 4 years
Installation method| Indoors
Operating temperature range| From 0°С to +65°С
Operating humidity| Up to 80%
Overall dimensions| 132 × 132 × 31 mm
Weight| 220 g
Service life| 10 years
Compliance with standards
Complete Set
- Fire Protect (Fire Protect Plus)
- Smart Bracket mounting panel
- Batteries CR2 (pre-installed) — 2 pcs
- Battery CR2032 (pre-installed) — 1 pcs
- Installation kit
- Quick Start Guide
Warranty
Warranty for the “AJAX SYSTEMS MANUFACTURING” LIMITED LIABILITY COMPANY
products is valid for 2 years after the purchase and does not apply to the
pre-installed battery.
If the device does not work correctly, you should t service — in half of the
cases, technical issues can be solved remotely!
The full text of the warranty
User Agreement
Technical support:
support@ajax.systems
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>