KLING FREITAG PLM 12K44 4 Channel Rational Power Management Amplifier User Guide

June 12, 2024
Kling Freitag

KLING FREITAG PLM 12K44 4 Channel Rational Power Management Amplifier User Guide
Channel Rational Power Management Amplifier

Important Safety Instructions

 Terminals marked with this symbol carry to constitute risk of electric shock. Use only high-quality professional speaker cables with This symbol, wherever it appears, dangerous voltage inside theThis symbol, wherever it appears, maintenance instructions in the accompanying literature. Please read the manual.
Caution
remove the top cover (or the rear section). No user serviceable parts inside. Refer servicing to
Caution
do not expose this appliance to rain and moisture. The apparatus shall not be exposed to dripping
Caution
These service instructions are for use servicing other than that contained in the operation

  1. Read these instructions.
  2. Keep these instructions.
  3. Heed all warnings.
  4. Follow all instructions.
  5. Do not use this apparatus near water.
  6. Clean only with dry cloth.
  7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
  8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus that product heat.
  9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding-type plug has two blades and a third grounding prong. The wide electrician for replacement of the obsolete outlet.
  10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
  11. Use only attachments/accessories specified by the manufacturer.
  12. Prohibited Icon Use onlywith the qart, stand, tripod, bracket, or table specified by the [ ‘manufacturer, or sold with the apparatus. When a cart isused, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
  13. Unplug this apparatus during lightning storms or ‘when unused for long periods of time.
  14. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed 1o rain or moisture, does not operate normally, or has been dropped.
  15. The apparatus shall be connected toa MAINS socket outlet with a protective earthing connection.
  16. Where the MAINS plug or anappliance coupler is used as the disconnect device, the disconnect device shall remain readily operable.
  17.  Comect disposal of this product: This symbol indicates that this product must not be disposed of with household waste according to the WEEE Directive (2012/19/EU) and your national _ law. This product should be taken toa collection center licensed forthe recycling of waste electrical and electronicequipment (EEE). The mishandling of this type of waste could have a possible negative impact on the environment and human health due to potentially hazardous substances that are generally associated with EEE. At the same time, your «ooperation in the correct disposal of this product will contribute to the efficient use of natural resources. For more information aboutwhere you can take your ‘waste equipment for recycling, please contact your local ity office, or your household waste collection service.
  18. Do not install in a confined space, such as a book a@se or similar unit.
  19. Do not place naked flame sources, such as lighted a@ndles, on the apparatus.
  20. Please keep the environmental aspects of battery disposal in mind. Batteries must be disposed-ofata battery collection point.
  21. This apparatus may be used intropical and moderate climates upto45°C.

LEGAL DISCLAIMER
Music Tribe accepts no liability for any loss which may be suffered by any person who relies either wholly or in partupon any description, photograph, or statement contained herein. Technical specifications, appearances and other information are subject to change without notice. All trademarks are the property of their respective owners. Midas, Klark Teknik, Lab Gruppen, Lake, Tannoy, Turbosound, TC Electronic, TC Helicon, Behringer, Bugera, Aston Microphones and Coolaudio are trademarks or registered trademarks of Music Tribe Global Brands Ltd. © MusicTribe Global Brands Ltd. 2023 All rights reserved.

LIMITED WARRANTY

Forthe applicable warranty terms and conditions and additional information regarding Music Tribe’s Limited Warranty, please see complete details online at community.musictribe.com/pages/support#warranty.

Introduction

Welcome
Thank you for choosing the Lab.gruppen PLM+ Series for your sound reinforcement needs. We are confident that you will be pleased with the performance, unique features, confiquration flexibility, reliability, and long-term durability offered by this product. For fastinstallation and use of this product, your welcome package includes this printed copy of the PLM+- Series Quick Start Guide. It provides a brief introduction to the features and functionality of the PLM+ Series, and it also contains the information required to safely install the productand placeit in service. Please read through thoroughly to become acquainted with the basic configuration and control options available. Itis recommended that you also review the full PLM+ Series manual and Lake Controller manual, available from www.labgruppen.com. Thank you again for placing your confidence in Lab.gruppen products.

Feature summary

Amplifier Platform Features

  • Four channels with four levels of total available frame power output: 20000 W, 12000 W, 8000 W, and 5000 W (@ 2.67 ohms)
  • Rational Power Management (RPM)
  • True flexibility in allocating power output across each channel to match requirement for more efficient use of amplifier inventory
  • Any channel is capable of delivering up to 5900 W (PLM 5K44 = 2000 W) power output drawing from total available power in each frame
  • Dedicated on-board surveillance and load monitoring for voice alarm applications
  • Advanced universal power supply
  • Regulated Switch-Mode Power Supply (R.SMPS™) maintains stability through fluctuations in mains voltage
  • Best-in-class Power Factor Correction (PFC)
  • Current Draw Modeling ((DM™) reduces peak mains draw
  • Breaker Emulation Limiter (BEL™) responds to available mains distribution
  • Under-Voltage Limiting (UVL™) allows continued operation through mains voltage drop
  • CAFE (Configuring Amplifiers For the Environment) software incorporates ESP™ (Equipment Specification Predictor) to assist in design, equipment specification and commissioning
  • Features controlled by on-board DSP
  • Amp Gain (Sensitivity) – Input gain (sensitivity) is set in the digital domain and controlled via Lake Controller software
  • ISVPL™-The Inter-Sample Voltage Peak Limiter (ISVPL) tailors each channel’s power output to the characteristics of the connected load.
  • Load Verification & Performance Monitoring – A comprehensive set of proprietary DSP-based tools enables load verification and real-time performance monitoring.

Lake Processing Features
Lake’s exclusive classic/linear-phase/FIR speaker processing platform with four throughputs

  • Group control with Raised Cosine™ MESA EQ™ asymmetric filters
  •  LimiterMax™ peak and RMS limiters
  • Extensive loudspeaker preset database
  • Comprehensive clocking management system with low latency sample rate conversion
  • Full support for Dante Controller
  • Multiple and redundantinputs with programmable failover
  • Comprehensive 3rd party protocol for integration potential with third- party matrix systems via purpose-developed middleware.

Installation

Unpacking
Carefully open the shipping carton and check for any damage to the device or the supplied accessories. Every Lab.gruppen productis tested and inspected before leaving the factory and should arrive in perfect condition. If any damage is discovered, please notify the shipping company immediately. Only the consignee may initiate a daim with the carrier or their insurers for damage incurred during shipping. Save the carton and packing materials for the carrier’s inspection.

Included in the box
In addition to the PLM+ device, the shipping carton includes the following items:

  • PLM+ Quick Start Guide (this Document)
  • ACmains lead (power cable) with Neutrik® powerCON® connector (PLM 20K44, 12K44 and 8K44 only) and AC socket plug according to ordering selection. PLM 5K44 uses a locking IEC connector.
  • Rearbrackets for additional rack support (pair) along with associated mounting hardware. Please keep the original carton and associated packaging to facilitate shipping of the device should the need arise.

Mounting
PLM+ is made for mounting in 19 inch racks. Four screw holes are available for attachment of the amplifier to the racks front rack rail. This device has no top or bottom vents; therefore, units may be stacked directly on top of one another. Sufficient space should be available at the rear to accommodate connectors and cables. In addition, allowance must be made for cable or loom bends within a rack.

Rear Mounting
Tworear support brackets, along with associated mounting hardware, areincluded with the PLM+ device. It is strongly recommended that these are used wherever possible. Fit the brackets to the vertical rails at the rear of the rack. The support brackets are reversible and may be fitted to point either to the front or rear of the rack; the proper orientation depends on the rack depth and position of the rear rack rails

Cooling and fan operation

PLM-+ devices use a forced-air cooling system with airflow from front to rear, allowing high continuous power levels without thermal problems. To facilitate maximum air flow, ensure that no objects such as rack doors or lids are placed at the front or rear of the rack. Never attempt to reverse the airflow. Make sure an adequate air supply is provided in front of the PLM-+ device, and that the rear of the device has sufficient space to allow air to escape. Itis recommended to keep the ambient temperature around the device as ool as possible. An increased temperature can have a significant negative impact on the expected lifetime on the components inside the PLM+ Series device.

Note: Fit solid blanks (not ventilation blanks) to unused rack spaces to ensure effective air circulation. Leaving gaps in betweenitems of equipment degrades the effectiveness of forced-air cooling. [finstalling one or more PLM+ devices in a rack with other fan-cooled equipment, confirm that all other equipment also uses front-to-rear aiflow for cooling.

If this precaution s not observed, there is a risk of overheating, as units with the reverse airflow will be drawing in air which has already been heated by the PLM+Series devices.

The PLM+ device is equipped witha sophisticated temperature sensing system which protects it from any overheating which may occuras a result of inadequate ventilation.

Operating voltage
PLM-+Series has a universal power supply and its mains nominal voltage is 100 — 240V. The PLM+ series can be ordered with a variety of mains plugs suitable for different territories.

Note: In-rush currentis controlled and limited during the soft-start sequence. This enables multiple PLM+ Series Devices on the same AC mains circuit to be turned on simultaneously.

Grounding
Use correctly-shielded balanced audio input connections to minimize hum and interference. PLM-+Series must be grounded (earthed) with the safety ground pin to the mains distribution system. NEVER disconnect the earth (ground) pin on the mains cable (AC power cord).

Product overview
Front panel
Additional information on operations using front panel controlsis available in the full PLM+ Series Operation Manual.
Product Overview

  1. Handles — Handles should be used when carrying, and when fitting into or removing from a rack. Ensure that rack doors or covers have sufficient depth to dear the handles.

  2. Dust Filters —Two dust filters are located behind metal covers. Loosen thumbscrews behind the handles to remove covers and remove filter elements for cleaning.
    Note: NEVER operate this device without the dust filters in place.

  3. Display —The display illuminates when deviceis on. Brightness and contrast can be adjusted via the front panel menu. A Screen Saver function tums off the display after 30 minutes of no activity. Press any button to turn on the display.

  4. Standby — Switches device between Onand Standby power modes.

  5. Mute Enable — Selection of MUTE ENABLE allows dynamic function buttons to operate as Mute controls for the module inputs and power output channels. EN The MUTE ENABLE button flashes when the mode is selected; a subsequent press deselects the mode. If left activated, MUTE ENABLE mode will automatically disable two minutes after last mute action.

  6. Meter — Successive presses of the METER button scroll through meter views: Amp, Temperature, Input and Module meters, returning to Home. Pressing METER from Menu Mode retums display to Meter Mode Home view.

  7. Menu — Pressing the MENU button changes the display to the top level menu, with dynamic function buttons enabling access to various information displays and function settings.

  8. Dynamic Function Buttons with LEDs (Left of LCD) — The function of these buttons change according to the currently selected view or menu.

    • In MenuMode they are used for menu navigation and for parameter selection
    • In Meter mode they provide Mute/Unmute function for the four inputs in conjunction with MUTE ENABLE.
    • Internal mute point(s) depend on selected meter view. The four LEDs display mute status (red= mute, green = unmute) as well as faultand warning indications. Global faults and warnings are indicated by simultaneous illumination of all four LEDs. Please refer to full Operation Manual for more information.
  9. Dynamic Function Buttons with LEDs (Right of LCD) — The function of these buttons change according to the currently selected view or menu.

    • In MenuMode they are used for menu navigation and for parameter selection
    • In Meter mode they provide Mute/Unmute function in conjunction with MUTE ENABLE. Internal mute point(s) depend on selected meter view. Please refer to full Operation Manual for more information. AIILEDs provide mute, clip, fault and warning indication for the power output channels.
  10. Communication LED – Steady white illumination indicates Module/Frame is selected in Lake Controller; flashing indicates communication with Lake Controller. Brightness is adjustable in the Frame page of Main menu.

  11. Rotary Encoder – Turning the encoder modifies various parameters in the menu. The ring around the encoder illuminates whenever a menu item is selected that permits adjustment of values. In Home view, the encoderis used to scroll through Meter views.

  12. Exit —Pressing EXIT returns the menu up one level when navigating in Menu mode. In Meter mode, EXIT returns display to Home view.

Rear panel
Product Overview

Input Connectors

  1. Analog Inputs —Four analog inputs are available on standard XLR-3F connectors, electronically balanced and featuring LakeIso-Float ircuitry. Impedance is 20 kohms; maximum input level is +26 dBu.

  2. AES3 Inputs — Two latching XLR-3F connectors accept four channels of AES3 digital audio. Input impedance is 110 ohms; ensure that 110 ohm digital audio cables are used.
    Output Connectors
    PLM 20K44, 12K44 and 8K44 are equipped with one of the two output connector options. Both options allow for Bridge Mode operation, which is activated in the Lake Controller software. Please refer to the Lake Controller Operation Manual for more information. The PLM 5K44 s equipped with both binding posts and speakON connectors, and does not support Bridge Mode operation.

  3. Binding Posts — Power outputs are available on four separate pairs of fully enclosed binding posts.

  4. speakON connectors — For PLM 20K44, 12K44 and 8K44, power outputs are available simultaneously ona single 8 pole connector and on two 4 pole connectors. The four-pole connectors carry outputs for channels 1&2 and 3&4 respectively. For PLM 5K44, connector 1 carries output channels 1 and 2, connect, or 2 carries channel 2, connector 3 carries channel 3 and 4, and connector 4 carries channel 4.
    Ethernet and Power Connectors

  5. Primary Network Connector — The primary Neutrik RJ45 etherCON® connection provides integration into an Ethernet control network which may include other Lake Processors and the Lake Controller software. Network connection permits full control of all functions along with real-time metering from aremote position. This device supports the Dante audio networking protocol for multichannel, high definition digital audio over the same Ethernet connection. Use the primary connector when using a star network topology, consisting of individual Cat-5e connections between the devices and an Ethernet switch. Alternatively,this connection can be used to daisy chain directly to another Lake Processor. Daisy chain topology is not recommended for use with Dante or AES67. For atechnical reference of the Ethernet Port, please refer to the full PLM-+ Series Operation Manual. Additional information is also available in the Lake Network Configuration Guide.
    Note: Additional processor configuration is required for a dual redundant network setup. See the Lake Controller Operation Manual for further details.
    Note: Do not create a closed loop when configuring multiple devices in an Ethernet network; this will cause a network malfunction.

  6. Secondary Network Connector — The secondary network connector can be used to daisy-chain multiple PLM+ Series devices. Alternatively, a Dante dualnetwork topology can be created by connectingall secondary network connectors to a separate Ethernet switch, ensuring full redundancy in the event ofa network component failure. Dual Redundancy needs to be enabled for this operation (can be done from Lake Controller or front panel).

  7. Mains Power Connector — AC mains input for the PLM 20K44, 12K44 and 8K44 s via a Neutrik powerCON connector, rated at 32A. Connector mates with supplied AC mains cable. PLM 5K44 uses a standard IEC locking connector. See previous section on Operating Voltage for more information.

Specifications

Numbers of amplifier channels 4
Total burst power all channels (share among channels with RPM) 5000 W
W 12000 W
2 ohms 900 W
2.67 ohms 1250 W
4 ohms 1250 W
8 ohms 1250 W
16 ohms 700 W
Hi-Z 70 V 1300 W
Hi-Z 100 V 1250 W
2 ohms 900 W
2.67 ohms 1250 W
4 ohms 1750 W
8 ohms 1350 W
16 ohms 700 W
Hi-Z 70 V 1450 W
Hi-Z 100 V 2000 W
Peak output voltage 150 V
Max output current 30 A
Rational Power Management (RPM) Any channel has potential to deliver the max

single channel output power
Default voltage limitation (can be lifted with RPM configuration| 147 V| 155 V| 175 V| 194 V
Protection features| Current Average Limiter (CAL), Very High Frequency Protection (VHF), Direct Current Protection (DC), Shirt Circuit Protection, Current-Clip Limiter, Voltage Clip Limiter, Temperature protection
Output Circuitry| Class D| Class TD| Class TD| Class TD
THD + N 20 Hz – 20 kHz for 1 W| < 0.05 %| < 0.05 %| < 0.05 %| < 0.05 %
THD + N at 1 kHz and 1 dB below clipping| < 0.04 %| < 0.04 %| < 0.04 %| < 0.04 %
Dynamic range| > 112 dB| > 112 dB| > 112 dB| > 112 dB
Channel separation (Crosstalk) at 1 kHz| > 70 dB| > 70 dB| > 70 dB| > 70 dB
Frequency response (1 W into 8 ohm, 20 Hz – 20 kHz)| + /- 0.05 dB| + /- 0.05 dB| + /- 0.05 dB| + /- 0.05 dB
Internal sample rate / Data path| 96 kHz / 32 bit floating point| 96 kHz / 32 bit floating point| 96 kHz / 32 bit floating point| 96 kHz / 32 bit floating point
Product propagation delay AES 96 kHz / analog input| 1.61 / 1.68 ms| 1.61 / 1.68 ms| 1.61 / 1.68 ms| 1.61 / 1.68 ms
Loudspeaker processing| Up to 4 modules of Classic/linear-phase/FIR cross- over, EQ, delay, LimiterMax™ – peak and RMS limiters
System tuning| Group control with Raised Cosine™ MESA EG™ asymmetric filters
Input redundancy / Matrix| Automatic 4 level input redundancy / 4 input mixers
System integration| Comprehensive 3rd party protocol over UDP Ethernet
Pilot tone generation and analysis| Yes
Load impedance analysis| Yes
Real Time Analyzer (RTA), 3rd party integration| Yes
Dante I/O| 8 X 8 (shared with AES67)
Network topology / redundancy| Flexible topology / Supports daisy-chained and Dual redundant networks
Sample rates / transport| 48, 96 kHz / Uni + Multicast
Network latency| 0.25, 0.5, 1.0, 2.0, 5.0 ms
Inputs| 4 AES inputs
Supported sample rates/ resolution| 44.1, 48, 88.2, 96, 176.4, 192 kHz / up to 24 bits
Sample rate conversion THD + N 20 Hz – 20 kHz unweighted| 0.00003 %

Important information

  1. Register online. Please register your new MusicTribe equipment right after you purchase it by visiting musictribe.com. Registering your purchase using our simple online form helps us to process your repair claims more quickly and efficiently. Also, read the terms and conditions of our warranty, if applicable.
  2. Malfunction. Should your MusicTribe Authorized Reseller not be located in your vicinity, you may contact the MusicTribe Authorized Fulfiller for your country listed under “Support” at musictribe.com. Should your country not be listed, please check if your problem can be dealt with by our “Online Support” which may also be found under “Support” at musictribe.com. Alternatively, please submit an online warranty claim at musictribe.com BEFORE returning the product.
  3. Power Connections. Before plugging the unit into a power socket, please make sure you are using the correct mains voltage for your particular model. Faulty fuses must be replaced with fuses of the same type and rating without exception

FEDERAL COMMUNICATIONS COMMISSION COMPLIANCE INFORMATION

Lab Gruppen
PLM + SERIES

PLM + SERIES
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:

  1. this device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.

Warning: Operation of this equipment in a residential environment could cause radio interference.

Important information:
Changes or modifications to the equipment not expressly approved by Music Tribe can void the user’s authority to use the equipment.

Hereby, Music Tribe declares that this product is in compliance with Directive 2014/35/EU,Directive 2014/30/EU, Directive 2011/65/EU and Amendment 2015/863/ EU, Directive 2012/19/EU, Regulation 519/2012 REACH SVHC and Directive 1907/2006/EC.

Standards applied:
EMC Emission EN55032, Class A. EMC Immunity EN55035, Electrical Safety EN62368-1, Class I

This equipment is tested and listed according to the U.S. safety standard ANSI/ UL 62368-1 and Canadian safety standard CSA C22.2 NO. 62368-1. Intertek made the tests and they are a Nationally Recognized Testing Laboratory (NRTL).
Full text of EU DoC is available at https://community.musictribe.com/
EU Representative: Music Tribe Brands DK A/S
Address: Gammel Strand 44, DK-1202 København K, Denmark
UK Representative: Music Tribe Brands UK Ltd.
Address: 6 Lloyds Avenue, Unit 4CL London EC3N 3AX, United Kingdom

KLING & FREITAG GmbH
Wohlenbergstr. 5 · D-30179 Hannover
Tel +49 (0)511 969970
www.kling-freitag.de
info@kling-freitag.de

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>