covetrus P080699A ProMAX IV Fluid Warmer User Manual

June 12, 2024
covetrus

covetrus-logo

covetrus P080699A ProMAX IV Fluid Warmer

covetrus-P080699A-ProMAX-IV-Fluid-Warmer-produt

ProMAX IV Fluid Warmer

The ProMAX IV Fluid Warmer is a medical device used to warm fluids before infusion. It has various features and indicators to ensure efficient and safe operation.

Appearance

  • Series Number
  • Name Ring Display Interface
  • Running Indicator Light
  • Alarm Indicator
  • AC Indicator Light
  • Temperature Adjustment
  • Power Switch
  • Loudspeaker
  • Return Button
  • Mute Button
  • Setting Confirmation Button
  • Drop Sensor Interface (Optional)
  • Pole Clamp (Hidden)
  • Power Cord Connector

Functionality

  • To hang the warmer
  • To check current operation of the warmer
  • To show that the warmer is currently running
  • To show that the warmer is in alarm state (red light with advanced-level alarms, yellow light with medium-level alarm)
  • To show that the warmer is connecting with AC power supply
  • To adjust to the required temperature
  • To power on or off the device
  • To alert or alarm with sound
  • To return to the previous interface or silence the alarm
  • To mute or activate sound
  • To enter the setting interface and confirm operation
  • To connect a drop sensor (if available)
  • To fix the warmer on a pole clamp
  • To connect the power cord

Home Interface

  • Series Number
  • Name
  • Alarm Display
  • Real-time Temperature
  • Set Temperature

Functionality

  • When an alarm occurs, this will display the relevant alarm marks and symbols
  • Display the real-time temperature of the warmer heating plate
  • Display the set temperature

Setting Interface Instructions

Press the Settings Confirm button to enter the following pages:

First Page

  • Temperature: Set the desired temperature and press OK to save the setting
  • Unit: Set the unit of temperature measurement
  • Speaker Sound Volume: Adjust the volume of the speaker sound
  • Key Sound Volume: Turn on or off the sound of key presses
  • Restore Factory Setting: Restore all parameters to factory settings
  • Languages: Set the language of the device interface

Second Page

  • Alarm of Abnormal Temperature: Configure temperature-related alarms
  • Equipment Information: View information about the warmer, including the version number

Installation Instructions

Note: After performing fixed installation with the pole clamp, the pole clamp can be returned to the hidden state inside the device by twisting the wingnut-shaped knob and rotating the pole clamp back into the slot.

Connect the Power Cable

  1. Insert one end of the power cable into the power socket of the warmer and the other end into the main socket.
  2. The power indicator will turn on when the power is switched on.

Note: Do not start the device when the fluid in the infusion tube is not flowing.

Infusion Set Installation

  1. Prepare the infusion set, fill it with liquid, and remove any bubbles.
  2. The device has two infusion pipe mounting slots. Install one or two infusion sets at the same time.
  3. Install the end of the infusion set from the top down into the heating plate slot of the warmer.

Usage Instructions

  1. Connect the power cord. The power indicator will turn on.
  2. Install the infusion set into the slot of the heating plate.
  3. Close the upper cover and insert the drop sensor into the corresponding interface of the Covetrus ProMAX IV Fluid Warmer (if necessary).
  4. After powering on, set the parameters and adjust the temperature.
  5. After use, long press the power button for about 3 seconds to turn off the warmer.

Alarms and Solutions

When an alarm sounds, first check the patient before determining the cause of the alarm.

Warnings and Precautions for the Covetrus® ProMAX IV Fluid Warmer

  • Please read this user manual carefully before using the Covetrus ProMAX IV Fluid Warmer. If you have any questions, please call Covetrus.
  • Before installing and using the Covetrus ProMAX IV Fluid Warmer, please perform a visual inspection to check whether the equipment has any of the following problems: damage to the housing, panel, or power supply, spilled fluid or liquid exposure, moisture, etc. If the panel is damaged, please call Covetrus.
  • This equipment must be operated by trained professional medical care personnel.
  • This device is used to warm drugs or blood inside an infusion line or blood transfusion line. Do not use it for other purposes.
  • Before installing and using the equipment, please confirm with a DVM or similarly-licensed personnel whether the drug can be heated and check appropriate heating temperature.
  • Prior to inserting fluid tubing into equipment, perform standard checks to ensure integrity and condition of line and that it is free of air prior to connection to the patient.
  • Before installing the equipment, please refer to this manual for correct installation to prevent the device from falling off the infusion stand. Pay attention to avoid blocking the loudspeaker portion of the panel. To prevent impact or damage to the equipment, please pick up and lie down gently. Do not wash the equipment.
  • When using the Covetrus ProMAX IV Fluid Warmer, please refer to the manual instructions. If alarm sounds, stop use and immediately troubleshoot the error. If necessary, please contact Triumph Medical for maintenance and testing, and ensure the device is certified to be in working order before resuming use.
  • When using the optional drop sensor, please pay attention to the corresponding relationship between the external drop sensor interface and the infusion set slot.
  • Please do not disassemble the equipment.

Appearance

Series Number Name Function
Ring To hang the warmer
Display Interface To check current operation of the warmer
Running Indicator Light Shows that warmer is currently running
****

Alarm Indicator

| Shows that warmer is in alarm state (red light with advanced-level alarms, yellow light with medium-level alarm)
⑤| AC Indicator Light| Shows that the warmer is connecting with AC power supply
⑥| Temperature Adjustment| Adjust to required temperature
⑦| Power Switch| Pressing and holding for 3 seconds to power on or single click to power off
⑧| Loudspeaker| To alert or alarm with sound
⑨| Return Button| Return to previous interface or silent alarm
⑩| Mute Button| To mute or activate sound
⑪| Setting Confirmation Button| Enter setting interface and confirm operation
⑫| Drop Sensor Interface (Optional)| To connect drop sensor
⑬| Pole Clamp (Hidden)| To fix warmer on pole clamp
⑭| Power Cord Connector| To connect power cord

Home Interface

Series Number Name Function
Alarm Display When an alarm occurs, this will display the relevant alarm

marks and symbols
②| Real-time Temperature| Display the real-time temperature of the warmer heating plate
③| Set Temperature| Display the set temperature

Setting Interface Instructions
Press the “Settings Confirm” button to enter the following page in sequence:

Page Description Function

First page

| Temperature| Set the desired temperature and press “OK” to save setting
Unit| Two units to choose from: °C and °F
Speaker Sound Volume| Set the speaker sound volume
Key Sound Volume| Set key sound on or off

Second page

| Restore Factory Setting| Restore all parameters to factory settings
Languages| Set language to select the required language

Alarm of Abnormal Temperature

| Set the difference between abnormal temperature and set temperature value (the default value is 1. When it is greater than or less than 1°C or 32°F high and low-temperature alarms will be triggered)
Equipment Information| View warmer information, version number

Installation Instructions

The Covetrus® ProMAX IV Fluid Warmer has two installation methods: hanging installation (with sling) or fixed pole clamp installation.

  1. Hanging installation: ****
  2. Fixed installation with clamp:
    • Open the hidden pole clamp and rotate 90° as shown in the first photo below.
    • Note: After performing fixed installation with the pole clamp, the pole clamp can be returned to the hidden state inside the device by twisting the wingnut-shaped knob and rotating the pole clamp back into the slot.
  3. Connect the power cable: Insert one end of the power cable into the power socket of the warmer and the other end into the main socket. The power indicator is on when the power is switched on.
    • Note: Do not start the device when the fluid in the infusion tube is not flowing.
  4. Infusion set installation: Prepare the infusion set, fill the infusion set with liquid, and drain the bubbles from the infusion set; The device has two infusion pipe mounting slots, and one or two infusion sets can be installed at the same time. Install the end of the infusion set from the top down into the heating plate slot of the warmer, as shown in the figure:
  5. No.1 infusion pipe slot
  6. No.2 infusion pipe slot

Use Instructions

The Covetrus® ProMAX IV Fluid Warmer is used to heat the infusion set’s liquid.

  1. Long press the power button, and the machine will be powered on.
  2. Fix the Covetrus ProMAX IV Fluid Warmer according to the installation diagram and connect the power cord. The power indicator will turn on.
  3. Install the infusion set into the slot of the heating plate, close the upper cover, and insert the drop sensor into the corresponding interface of the Covetrus ProMAX IV Fluid Warmer (if necessary).
  4. After powering on, set the parameter and adjust the temperature.
  5. After use, long press the power button for about 3 seconds to turn off the warmer.

Alarms and Solutions

When an alarm sounds, first check the patient before determining the cause of the alarm.

Description Alarm reason Solution

Door Open

| If the device is open or did not properly shut, an audible and visual alarm will appear| Close the door, or press mute button or return button to remove the alarm

High Temperature

| Occurs when the temperature is higher than the set value by 1°C or 32°F. The default is 1°C, and the alarm range can be increased in the setting interface by the user up to 3°C or 37.4°F.| When the temperature goes back to the control range, it automatically eliminates the alarm. Press the mute or return button to remove the alarm.

Low Temperature

| Occurs when the temperature is lower than the set value by 1°C. The default is 1°C, and the alarm range can be increased in the setting interface by user with a max of 3°C lower than the set temperature.| When the temperature goes back to the control range, it automatically eliminates the alarm. Press the mute or return button to remove the alarm.

Packing list of Covetrus® ProMAX IV Fluid Warmer

  • One Covetrus ProMAX IV Fluid Warmer Main Unit
  • One Power Cord
  • One Sling
  • One Manual and Certificate of Quality

Maintenance Regulations

  • The Covetrus ProMAX IV Fluid Warmer has a free warranty period of 1 year from the purchase date.
  • The starting date of the warranty period is subject to the purchase date and the invoice.
  • Note: the machine damage caused by the following conditions is not covered by the free warranty:
  1. Faults caused by unauthorized modification or maintenance due to improper use.
  2. Fire, flood, wind, earthquake, abnormal voltage, and other natural faults and damages.
  3. The machine is bumped or damaged due to improper operation during handling after purchase.
  • In case of damage or failure under the above circumstances, Triumph Medical can provide maintenance, but a certain fee will be charged accordingly.

Maintenance records

**Date** **Repair Content** Replace Parts **Repairman**
Material name Quantity

Note: If you have any questions, please contact Triumph Medical.

  • Questions?
  • 855-724-3461
  • Distributed by:
  • Covetrus® North America
  • 400 Metro Place North
  • Dublin, OH 43017
  • covetrus.com
  • REV: 0423
  • Reorder #080699
  • AH-ProMAXIVFluidWarmer-01
  • Manufacturer:
  • Triumph Medical Services, Inc
  • 891 Bolger Court
  • Fenton, MO 63026
  • 888-962-0662

Documents / Resources

| covetrus P080699A ProMAX IV Fluid Warmer [pdf] User Manual
P080699A ProMAX IV Fluid Warmer, P080699A, ProMAX IV Fluid Warmer, Fluid Warmer, Warmer
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

covetrus User Manuals

Related Manuals