InfraComfort HY01WE Programmable Non Wi-Fi Thermostat User Manual
- June 12, 2024
- InfraComfort
Table of Contents
HY01WE Programmable Non
Wi-Fi Thermostat
User Manual
Many thanks for your selection of our products and services, and also for your trust and support to us
Product Specification
- Power: 100-240V 50/60Hz(WE,WW) two AA* 1.5V alkaline batteries(BW)
- Range of temperature display: 0~40°C/32~104°F
- Insulating condition: Normal environment
- Running program: Set per 1 week as a cycle
- Installation: Wall mounted or on battery seat
- Working environment temperature: 0~70°C/32~122°F 5A(gas boiler heating)
- Range of temperature adjustment: 5~35°C/41~95°F
- Display accuracy: 0.5°C or 1°F
- Output: Switch relay
- Probe sensor: NTC(10k)1%
- Size(mm): 1309027 And 1077828
- Contact capacity: 16A(electric heating) 3A(water heating)
Displays & Buttons
Operation Key
NO: | symbols | represent |
---|---|---|
A | SET | set key: short press it to switch programme mode to manual mode. At |
programme mode, press “ ”or” ” to adjust the value, it will automatic enter
into temporary manual mode
B| +| Increasing key
C| pRG| clock key: short pressing is setting clock, long pressing is setting
programme Keys locked/unlocked:press “ ”and“ ”at the same time for 3 seconds
D| –| Decreasing key
E| | Power on/off key
Run Mode
Factory Preset Mode
Interval| Monday to
Friday| the default
value| Saturday and
Sunday| the default
value|
---|---|---|---|---|---
1st| 06:00-08:00| 20°C| 06:00-08:00| 20°C
2nd| 08:00-11:30| 15°C| 08:00-11:30| 15°C
3rd| 11:30-13:30| 15°C| 11:30-13:30| 15°C
4th| 13:30-17:00| 15°C| 13:30-17:00| 15°C
5th| 17:00-22:00| 22°C| 17:00-22:00| 22°C
6th| 22:00-06:00| 15°C| 22:00-06:00| 15°C
Mode| explain| printscreen
---|---|---
Programming
mode| Press” SET “to switch into programme mode (As shown in picture one)
Programme illustration
5+2 programme function(advanced options contain of 6+1 and 7 days programme
function, you can also cancel this programme function), that is Monday to
Friday is the same setting value, and Saturday to Sunday is the same setting
value,. Every day can be divided into 6 time interval
Setting the programme value:long press” PRO” to enter into programme setting
mode, then short press” pR O “to switch, press” + “or” —”to adjust value.|
Manual Mode| Press ” SET ” to enter into manual mode (As shown in picture
two), press” + “or” —”to adjust value.|
Temporary
manual mode| ” ”
at programme mode,press + ” or —” to adjust the value, it will automatic enter
into temporary manual mode|
Advanced Options
Advanced options can be classified to two sets MODE 1:
Turn off thermostat,long press for 3 seconds,it will display A01-A09,then
press to switch between these options
Display
symbol| Option content| Press“ +”or“ ”to adjust value
---|---|---
| temperature compensation( A01)| Press “ +”or“ -” key to adjust setting value
(—9~9 ) increment:0.5°C.
| Start differential temperature(A02 )| Range:1°C~5°C:
1.When the setting temperature is higher than or equal to the sum of indoor
temperature and the start differential temperature, the heating equipment will
turn on.
2.When the indoor temperature is higher than or equal to the sum of the
setting temperature and the start differential temperature, the heating
equipment will turn off.
| Keypad (A03)| 0 half locked:all keys are locked except for the on-off key;
1 full locked,all keys are locked including the on-off key.
| Sensor choice( A04)| N1:single build-in sensor;
N2:single build-out sensor;
N3:build-in and build-out sensor
| high temperature protection(A05)| Range:35~70 When the lowest setting
temperature is 35°C,press “ ”,it will display “ ”, high temperature
protection function is canceled; if the indoor
temperature is higher than the high temperature protection value,the heating
equipment will be cut off. Default value is =45°C
---|---|---
| low temperature protection(A06)| Range:5°C~10°C ;When the highest setting
temperature is 10°C,press “ ”,it will display “ ”, low temperature protection
function is canceled; if the indoor
temperature is lower than the low temperature protection value,the heating
equipment will turn on. Default value is =5°C
| setting temperature lowest limiting value(A07)| Range:1°C~10°C:
| setting temperature highest limiting value(A08)| Range:30°C~70°C
| Week programme choice(A09)| MON TUE WED THU FRI SAT SUN : represent
7days programme
MON TUE WED THU FRI SAT :represent6+1 programme
MON TUE WED THU FRI :represent5+2 programme
“- – ”represent programme is canceled
MODE 2:
- Turn off thermostat, long press “ for 3 seconds it will display B01-B05,then press “ to switch between these options.
Display
symbol| Option content| Press“ ”or“
”to adjust value
---|---|---
| Valve control
option (b01)| 0 represent valve is controlled by the thermostat
1 represent valve is not controlled by the thermostat, it’s always closed
| Anti-freezing
(Descaling
function)
function option
(b02)| 0 close,1 open。
Anti-freezing function:when valve is continuously closed over100 hours,it will
be
opened for3 minutes。
| GA/GB option
(b03)| 0-GA:valve switch protection time is about 3 seconds;
1-GB:valve switch protection time is about 15 seconds;GB no anti-freezing
function
| °C or °F (b04)| Celsius degree or Fahrenheit degree
| Restore factory
(b05)| Display A o,Long press PRG key whole show Restore factory
| |
---|---|---
Please use a small screwdriver (about
3.5mm width) insert. The notch of LCD
broad about 4mm| Up the screwdriver with a little
pressure, and Open the LCD panel| Please use two screw to fasten the
power panel the hidden box.
| |
LCD panel and power panel should be
connected( please connect them softly
to avoid the line broken)| LCD panel also be connected to the
hidden box| Please press the cover softly and
finished the installation.
Wiring Diagram
NO: Normally-Open point
NC: Normally-Closed point
COM:Public terminal of relay