The IQ Panel4 is a versatile module that provides various applications for
installation and operation. It features three 8-pin receptacle interfaces for
easy connections to other modules such as PowerG, Zigbee, and other Security
Radios. These additional modules are optional and come with their own antennas
and FCC licenses. The built-in Z-Wave operates at frequencies of 908.4,
908.42, 916, 919.8, and 921.4 MHz, with an output power of up to 2.8 dBm. For
detailed data and protocol specifications, please contact Qolsys for the
technical specifications. The IQ Panel4 complies with Part 15 of the FCC Rules
and meets the FCC radiation exposure limits for an uncontrolled environment.
It also complies with Industry Canada license-exempt RSS standards.
FCC Compliance
- FCCID: 2AAJXQS-IQP4Z
- Tradename: Qolsys
- Model Number: IQPanel 4
Industry Canada Compliance
- IC: 11205A-QSIQP4Z
Product Usage Instructions
Radiation Exposure: To ensure compliance with radiation exposure limits,
it is recommended to install and operate The equipment with a minimum distance
of 27 cm between the radiator and your body.
Antenna and Transmitter Usage: The device and its antenna(s) should not be co-located or operated in conjunction with any other antenna or transmitter, except for tested built-in radios.
Warranty Information: It is important to note that any changes or modifications not expressly approved by Qolsys Inc. will void the user’s authority to operate the equipment and will also void the product warranty.
General Applications
The Qolsys IQ Panel4 features the Quectel Wireless module Model SC650T-NA with FCC ID: XMR2019SC650TNA providing cellular connections (E-UTRA-FDD) Bands 2, 4, 5, 7, 12, 13, 14, 25, 26 and 66. The Quectel module incorporates also provides WiFI 2.4 / 5 GHz and Bluetooth Low Energy 4.2 support. A main antenna and Diversity antenna are embedded in the Qolsys MB to support these features. Additionally, the Qolsys IQ Panel4 includes the EFR32ZG23 modem for air connection to compatible Z-wave Devices at the 908.4, 908.42, 916, 919.8, and 921 MHz and includes an embedded Antenna. These antennas are not removable and are not designed to be modified.
Installation and Operation
The module has three simple 8-pin receptacle interfaces for connections to other modules such as PowerG, Zigbee, and other Security Radios. These additional modules are optional and will provide their own Antennas and FCC Licenses The built-in Z-Wave operates at 908.4, 908.42, 916, 919.8, and 921.4 MHz with an output power of up to -2.8 dBm. Data and protocol specifications are beyond the scope of this document. Please contact Qolsys for the technical specifications.
FCC Compliance (Declaration of Conformity)
FCCID: 2AAJXQS-IQP4Z Tradename: Qolsys Model Number: IQPanel 4
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
a minimum distance of 27 cm between the radiator & your body.
Industry Canada Statement of Compliance
IC: 11205A-QSIQP4Z
This device complies with Industry Canada license-exempt RSS standard(s).
Operation is subject to the following two conditions:
- This device may not cause interference, and
- This device must accept any interference, including interference that may cause undesired operation of the device.
Radiation Exposure Statement:
This equipment complies with IC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
a minimum distance of 27 cm between the radiator & your body.