The installation should be performed by a qualified electrician according to this manual. Please keep the instructions.

The PIR motion sensor monitors the heat radiated by the objects within its range. Depending on the change of the thermal background, it switches on / off the load connected to it.

CHARACTERISTICS

  • Voltage.220-240 V AC / 50-60 Hz
  • Power: …15 W
  • Rated luminous flux … 1410 m
  • Corelated colour temperature ……….. 4000 K
  • Colour Rendering Index …… Ra≥80
  • Beam angle:..120°
  • Dimensions:.250/55 mm
  • Ambient Light:. < 3 – 2000 Ix (adiustable)
  • Time delay: Min. 10 sec. #3 sec. / Max. 3 min. ‡30 sec. (adjustable)
  • Detection Range:..360°
  • Detection Distance:..3 m
  • Installation Height:. 2.2 m – 4 m (ceiling mounting)
  • Detection Motion Speed: …. 0.6-1.5m/S
  • Working Temperature:. – 10°C +40°C
  • Working Humidity:  < 93%RH
  • IP rate: P20

SENSOR CHARACTERISTICS

INSTRUCTIONS FOR INSTALLATION OF THE CEILING LAMP

  1. Turn off the power supply before installation.
  2. Unscrew the plastic screw nut and remove the lampshade
  3. Drill three holes into the ceiling and insert the plastic dowels.
  4. Fix the base to the ceiling.
  5. Connect to the power supply according to the symbols.
  6. Mount the cover to the base .

NOTES:

  • Make sure the installation is performed according to the instructions.
  • Created to work indoor (IP20). Do not install in wet environment.
  • Not suitable for accent lighting.

TAKING CARE OF THE NATURAL ENVIRONMENT CLEANLINESS
The product and its components are not harmful to the environment. Please dispose the package elements separately in containers for the corresponding material.

  • Please dispose the broken product separately in containers for out of usage electrical equipment.

TESTING THE CEILING LAMP

  • Before switching the main power supply on, turn TIME knob anticlockwise to ” -” and the LUX knob clockwise to the symbol ” sun”.Yavor-M-SCLP1540-LED-С-LED-Ceiling-Light-FIG-5
  • Switch on the power; the lamp will have no signal at the beginning. After Warm-up 30sec, the lamp can start work. If it receives the induction signal, the lamp will turn on. While there is no another induction signal any more, the lamp should stop working within 10sec±3sec.
  • If a movement is detected in the controlled area, the sensor will turn on the lamp. If a movement is detected again during the time delay, the time will be recalculated based on the initial settings.
  • To test the sensor sensitivity to ambient light, turn LUX knob anticlockwise to the symbol ” half-moon”. If the ambient light is more than 3Ix, the sensor will turn off the lamp, even if there is a movement in the detection area. If the ambient light is less 3Ix, the sensor will turn on the lamp, once detecting a moving object.

POSSIBLE REASONS FOR SENSOR MALFUNCTIONS

The lamp does not turn on:

  • Please check if the power and load connection is correct.
  • Make sure the lamp is not defective.
  • Check if the working light corresponds to the ambient light.
  • When testing in daylight, please turn LUX knob to ,,sun” position, otherwise the sensor lamp could not work!

The sensitivity is poor:

  • Please check if there is hinder in front of the detection window to prevent from receiving the signals.
  • Please check if the ambient temperature is too high.
  • Please check if the moving orientation is correct.
  • Please check if the signals source is in the detection area.
  • Please check if the installation height corresponds to the height shown in the instruction.

The sensor doesn’t switch off the load automatically:

  • Check if there are continual signals in the detection area.
  • Make sure TIME knob is not set to “+”
  • Check if the power corresponds to the instruction.
  • Make sure there are no heaters in the sensor range.