UltraLux LPSW18CCT LED Ceiling Lamps Installation Guide

June 12, 2024
ULTRALUX

UltraLux LPSW18CCT LED Ceiling Lamps

UltraLux LPSW18CCT LED Ceiling Lamps

TECHNICAL PARAMETERS

Voltage AC: ……………………………….. 220-240 V AC/ 50-60 Hz
Power: ……………………………………………………………….. 18W
Rated luminous flux: ……………………………………….. 1800 Im
Correlated Color Temperature (CCT):
…………………………………… 3000/4000/6500 K (adjustable)
Beam angle: ………………………………………………………… 120′
Ambient light: …. 2 Lux, 10 Lux, 50 Lux, Disable (adjustable)
Time delay: ……………………. 5S, 30S, 60S, 300S (adjustable)
Detection range: …………………………………………. 360’/ 180′
Detection distance: ………………………… 1 m-6m (adjustable)
Installation Height:
……………………………………….. 2.5-3.5m (ceiling mounting)
……………………………………………… 1-1.8m (wall mounting)

Sensor:
HF System: ……………………….. 5.8 GHz ISMB band, CW radar
Transmission Power: ……………………………………… <0.2mW
Power Consumption: ……………………………….. approx. 0.9 W
Detection Motion Speed: ……………………………. 0.5-1.5 m/S
Working Humidity: ……………………………………….. <93% RH
Color Rendering Index (CRI): ………………………………. Ra2e80
Working temperature: …………………………… -10°( + +40 ‘C
Protection rating: …………………………………………………. IP54
Dimensions: ……………………………………………… 220/55 mm
Warranty: ………………………………………………………… 2 years

SAFETY INSTRUCTIONS

  1. Performing any activity with the power supply on constitutes potential hazard of electric shock. Prior to mounting, power supply must be switched off by using the mains switch.
  2. The fixture can be installed only on a flame-resistant base with ignition temperature at the least 200 ‘C and does not deform or soften (e.g. metal, concrete, plaster).
  3. Activities related to connection to the power supply are to be commissioned to a person with appropriate authorization.
  4. The fixture, when properly assembled, may only be connected to a properly functioning electrical system with compliance with the applicable standards.
  5. Clen only with dry cloth
  6. The light fixture heat itself while working, so in case of necessity prior to undertaking its replacement, wait until cool down.
  7. Do not cover the fixture. To avoid any fire hazard, provide unrestricted air flow to the heated fitting parts.
  8. Prior to starting operating, make sure the mounting of the product has been performed appropriately, eliminating the hazard of defective operation, not endangering the surrounding and the users.
  9. The importer/supplier bears no responsibility for damages resulting from failure comply with these instructions.

FUNCTIONS

Identifying day and night – The ceiling lamp can work during the day and at the night when the last two DIP switches (5 and 6) are in the Disable position.
Time delay- Time delay (DIP switches 3 and 4) can be adjusted according to the user’s wishes. The minimum time is 5 seconds. The maximum time is 300 seconds.
Detection distance – It is possible to adjust the detection distance (DIP switches 1 and 2). Depending on their combination, an detection distance 6m, 4m, 3m, 1 m (100%, 75%, 50%, 25%) is achieved.

DETECTION RANGE DIAGRAM

Detection Range Diagram

EXAMPLE

The ambient light in the room is greater than 2 Lux. The presence of motion does not activate the ceiling lamp.
Example
The ambient light in the room is less than 2 Lux. The motion detection activates the ceiling lamp.
Example
300 seconds after the last motion detection, the ceiling lamp will turn off.
Example

WIRING DIAGRAM AND FUNCTIONAL ADJUSTMENTS

Wiring Diagram And Functional Adjustments

INSTALLATION

  1. Turn off the power supply.
  2. Hold both sides of the handle to remove the bracket, unscrew the screw to remove the back cover.
  3. Pass the cable through the center hole of the bracket and screw the bracket to the ceiling.
  4. The cable passes through the guard sleeve and is connected to the terminal. Choose a color temperature.
  5. Adjust the sensor settings. Secure the cable and install the back cover according to the original position.
  6. Puttee wire into the groove of the chassis.
  7. Point the light at the bracket and buckle it.
  8. Installed ceiling light.

TAKING CARE OF THE NATURAL ENVIRONMENT CLEANLINESS

  1. The product and its components are not harmful to the environment.
  2. Please dispose the package elements separately in containers for the corresponding material.
  3. Please dispose the broken product separately in containers for out of usage electrical equipment.

Taking Care Of The Natural Environment Cleanliness
Taking Care Of The Natural Environment Cleanliness
Taking Care Of The Natural Environment Cleanliness

SIMPLIFIED EU DECLARATION OF CONFORMITY

Hereby, BORIANA LTD declares that the radio equipment type LED CEILING LAMPS
LPSW18CCT, LPSB18CCT is in compliance with Directive 2O14/53/EU.

The full text of the EU declaration of conformity is available at the following internet address: www.ultralux.bg

QR-code| QR-
code
---|---

This product contains a light source of energy efficiency class D.
Symbols

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

ULTRALUX User Manuals

Related Manuals