GEWISS GATEWAY KNX/DALI 64/16 IP Chorusmart Switch Range Instruction Manual

June 12, 2024
GEWiSS

GEWISS GATEWAY KNXDALI 6416 IP Chorusmart Switch Range

GEWISS GATEWAY KNXDALI 6416 IP Chorusmart Switch Range

SAFETY PRECAUTIONS

Warning! The safety of this appliance is only guaranteed if all the instructions given here are followed scrupulously. These should be read thoroughly and kept in a safe place. Chorus products can be installed in environments which are dust-free and where no special protection against the penetration of water is required. They shall be installed in compliance with the requirements for household devices set out by the national standards and rules applicable to low-voltage electrical installations which are in force in the country where the products are installed, or, when there are none, following the international standard for low-voltage electrical installations IEC 60364, or the European harmonization document HD 60364. Gewiss sales organization is ready to provide full explanations and technical data on request.

ATTENTION: the device must only be installed by qualified personnel, observing current regulations and the guidelines for KNX installations.

ATTENTION: the unused BUS signal cables, and the electrical continuity conductor, must never touch any live elements or the earthing conductor!

ATTENTION: disconnect the mains voltage before connecting the device to the electricity supply!

PACK CONTENTS

  • 1 KNX/DALI Gateway 64/16 IP – from DIN rail
  • 1 BUS terminal
  • 1 heat-shrinking sheath 1.2 x 2cm for additional BUS cable insulation
  • 1 installation manual

BRIEFLY

The KNX/DALI Gateway 64/16 IP – from DIN rail – allows communication between the
ballasts that implement the DALI protocol (specifically for lighting control), and the KNX
Home and Building Automation system.
The KNX/DALI Gateway acts as both a DALI Master device and a power supply for the
connected ballasts. Additional DALI power supplies are not allowed. The Gateway can
also control both single-battery DALI emergency lamps (with switchable or non- switchable ballast) and DALI emergency lighting systems with a centralised battery.
The device is fitted with (Figure A ):

Briefly

  1. RJ-45 socket-outlet for an Ethernet connection
  2. KNX BUS connector
  3. Power supply
  4. DALI connector
  5. LED for programming physical address
  6. Button key for programming physical address
  7. Move push-button
  8. Prg/Set push-button
  9. ESC push-button
  10. Fault signalling LED (ERR)
  11. Ethernet line signalling LED (LNK)
  12. Display (2×12 characters) for DALI start-up

ASSEMBLY

Assemble the device on a 35mm DIN rail. To do this, insert the upper device coupling in the DIN rail then rotate it downwards until you hear the “click” that indicates it has been blocked on the rail. For the electrical connections, refer to figure B.

Assembly

MAINTENANCE

The device does not require any maintenance. Use a dry cloth if cleaning is required.

PROGRAMMING

For the initial start-up of the KNX part, the device must be configured with the ETS software. To program the DALI part, the device can be directly configured locally or via Ethernet (using the integrated web server). Detailed information about the configuration parameters and their values can be found in the Technical and User Manuals, available on the website (www.gewiss.com).

TECHNICAL DATA

Communication KNX BUS DALI BUS
Power supply From 100 to 240V AC/DC, 50/60Hz KNX BUS, 29V DC SELV
KNX bus cable KNX TP1
DALI BUS Connection of up to 64 ballasts. DALI power supply voltage

16-20V DC, resistant to short-circuits (max 250 mA). Category 1 (EN 62386-103)
Command elements| 1 miniature button key for programming the physical address – KNX 3 multi-purpose button keys (Move, Prg/Set, ESC) on the front of the display, to start up the device and set the parameters
Display elements| 1 red LED for programming the physical address – KNX 1 red LED for signalling faults (ERR) 1 yellow LED for signalling the Ethernet line (LNK) 1 liquid crystal display consisting of 2 rows (12 characters each)
Maximum dissipated power| 7W
Usage environment| Dry indoor places
Operating temperature and storage| 5 to +45°C
temperature| 25 to +70°C
Relative humidity| Max. 93% (non-condensate)
Connection to the KNX bus| Coupling terminal, 2 pins Ø 1mm
Network connection| RJ45 socket-outlet
Electric connections| Screw terminals. Max cable section: 2.5mm2
Degree of protection| IP20
Size| 4 DIN modules
Reference Standards| Low Voltage Directive 2006/95/EC Electromagnetic Compatibility Directive 2004/108/EC, EN 50491, EN 60926, EN 62386-103
Certifications| KNX

CUSTOMERS SUPPORT

|
---|---

According to applicable UK regulations, the company responsible for placing the goods in UK market is:
GEWISS UK LTD – Unity House, Compass Point Business Park, 9 Stocks Bridge Way, ST IVES
Cambridgeshire, PE27 5JL, United Kingdom tel: +44 1954 712757 E-mail: gewiss- uk@gewiss.com

+39 035 946 11
8:30 – 12:30 / 14:00 – 18:00
lunedì – venerdì / monday – friday

www.gewiss.com

Logo

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

GEWiSS User Manuals

Related Manuals