KACISE KUS630 Series Ultrasonic Level Sensor User Manual

June 12, 2024
KACISE

KACISE KUS630 Series Ultrasonic Level Sensor

Product Information:

Product Name: Ultrasonic Level Sensor
Model No.: KUS630 Series
Manufacturer: Xi’an Zhizun International Trade Co., Ltd.

Features:

  • High sensitivity
  • Fully sealed
  • IP68 corrosion resistant housing suitable for corrosive media and applications

Dimensions:

Sensor Picture:
Dimension (unit: mm):

Product Usage Instructions

Electrical Connection:

The ultrasonic sensor has the following PIN connections:

PIN No. Cable Color Definition
1 Red Power supply+
2 Black GND
3 Yellow Switch output
4 White Switch output
5 Brown RS485 A+
6 Green RS485 B-

Parameter:

Model: KUS630
Measuring Range: 600~12000 mm, 1200~30000mm,1800~50000mm
Blind Area: 0~600 mm (the working area within 600mm is unstable and not recommended)
Power Supply: 3.3~24V DC, ripple 10%SS
Working Current: 45mA (maximum measurement speed), Low-power version: hibernation power 0.3mA, transmit power consumption is 20mA (2ms), receive power consumption is not more than 8mA (150ms)

Output:

  • Analog output
  • Switch output
  • RS485 digital output
  • UART serial port output

Accuracy: 1% F.S

Temperature Compensation: Yes

Description of Sensor Functions:

Analog Output:

To set up the analog output:

  1. Connect the sensor to the computer
  2. Set a near distance point D1
  3. Set a far distance point D2
  4. Set the voltage or current of D1 output
  5. Set the voltage or current of D2 output
  6. Set analog output to switch characteristic output
  7. Set the analog output to a linear output or switch output option
  8. Reset sensor to make the new parameters take effect

Switch Output:

The switch output has 8 different functions:

  1. Default window mode normally open
  2. Default window mode normally closed
  3. Default single point switch mode normally open
  4. Default single point switch mode normally closed
  5. Default single point hysteresis mode normally open
  6. Default single point hysteresis mode normally closed
  7. Default object detection mode normally open
  8. Default object detection mode normally closed

Digital Output: RS485
The communication protocol for RS485 digital output is Modus-RTU. For more information, please contact us for the software engineering guide.

Contact Information:

Tel: 0086-029-87858956

Email: contact@top1sensor.com

Ultrasonic Level Sensor User Manual Model No. KUS630 Series

Feature

  • High sensitivity
  • Fully sealed
  • IP68corrosion resistant housing,suitable for corrosive media and applications

Dimension

Sensor picture

Dimension (unit: mm)

KACISE-KUS630-Series-Ultrasonic-Level-Sensor-2

Electrical connection

PIN No. Cable color Definition
1 red Power supply+
2 black GND
3 yellow analog output
4 blue RS485 A+ or UART TXD
5 green RS485 B- or UART RXD
PIN No. Cable

color

| Definition| Note
---|---|---|---
1| Red| Power supply+| 3.3v~30v voltage range
2| Black| GND|


3

| ****

Yellow

| ****

Switch output

| Load capacity of switch terminal is 1A and 60V, support independent logic two road switch output at most, the two terminals are the two contact points of the switch,

They don’t distinguish between the positive and negative

poles, and can connect at will.

4| White| Switch output
5| Brown| RS485 A+|
6| Green| RS485 B-|

Parameter

Model: KUS630

Measuring range| 600~ 12000 mm,

1200~30000mm,

1800~50000mm


Blind area

| 0 ~ 600 mm (the working area within 600mm is an unstable, it is not recommended to work in this range);

Minimum 300 mm blind zone version can be customized.

Power supply| 3.3~24V DC , ripple 10 %SS



Working current

| ≤ 45mA( maximum measurement speed)

Low- power version: the hibernation power ≤ 0 . 3 mA, the transmit power consumption is 20 mA ( ≤ 2 ms), and the receive power consumption is not more than 8mA (≤ 150ms).



Output

| 1.Analog output 2.Switch output

3. RS485 digital output.

4. . UART serial port output

Accuracy| ≤ 1 % F.S
Temperature

compensation

| Yes

The working conditions

Operating temperature -25 ~70℃(233~358K)

Storage

temperature

| -40~85℃(233~358K)

Other instructions

Electrical 5-wire cable / 6 wire cable for switch ouput
Protection grade IP68
Material Housing PVC /PVDF/PTFE      ( Default PVC)

Description of Sensor Functions

Analog output

KACISE-KUS630-Series-Ultrasonic-Level-Sensor-3

The analog output can be set through RS485 interface, the setting procedure is as follows,

Step 1: connect the sensor to the computer through serial port debugging assistant or Modbus debugging assistant.

Step 2: set a near distance point through RS485

Step 3: set a far distance point through RS485

Step 4: set the output voltage or current of the near distance point

Step 5: set the output voltage or current of the far distance point

Step 6: set the analog output to the switch characteristic option

Step 7: set the analog output to a linear output or switch output option

Step 8: reset the sensor to make the new parameters take effect

KACISE-KUS630-Series-Ultrasonic-Level-Sensor-4

Switch output There are 8 different functions

  1. Default window mode normally open
  2. Default window mode normally closed
  3. Default single point switch mode normally open
  4. Default single point switch mode normally closed
  5. Default single point hysteresis mode normally open
  6. Default single point hysteresis mode normally closed
  7. Default object detection mode normally open
  8. Default object detection mode normally closed

Digital output: RS485

Communication protocol is Modus-RTU. For more information please contact us for the software engineering guide

KACISE-KUS630-Series-Ultrasonic-Level-Sensor-5 KACISE-KUS630-Series-Ultrasonic-Level-Sensor-6

Installation conditions
If the sensor is installed at the environment temperature fall below 0℃, it should do well on the protective measures. In case of direct mounting of the sensor in a through hole using the nuts, it has to be fixed at the middle of the housing thread

Order information

Model No.: Output Max range Description



KUS630

| Analog output|  |
RS485 digital output|  |
Switch output|  |
 | XXX mm| Default 10000 mm
RS485| 10000mm|

Contact us

Xi’an Zhizun International Trade CO., Ltd.

Tel: +86-29-87858956
E-mail: contact@top1sensor.com
Getting more info & supports from http://www.top1sensor.com

Email:contact@top1sensor.com

Xi’an Zhizun International Trade Co., Ltd. Ultrasonic Sensor

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals