GE APPLIANCES JGP3030DLWW 30 Built In Gas Cooktop with Dishwasher Instructions

June 12, 2024
GE Appliances

GE APPLIANCES Logo PROPANE CONVERSION INSTRUCTIONSGE APPLIANCES
JGP3030DLWW 30 Built In Gas Cooktop with Dishwasher

JGP3030DLWW 30 Built In Gas Cooktop with Dishwasher

WARNING
Explosion Hazard
Death or serious injury can result from failure to follow these instructions.

  • Replace all parts and panels before operating.

The pressure regulator and the burner orifices are set for natural gas To use propane gas, the regulator and burner orifices must be converted.
WARNING
Do not operate the cooktop when using propane (bottled) gas before converting the pressure regulator and burner orifices for propane gas use. Failure to do so could cause high flames and toxic fumes which can result in serious injury.
The propane orifices are attached to the regulator which is packaged with the unit.

TOOLS REQUIRED:

  • Flat bladed screwdriver
  • Nut drivers: 1/4″, 9/32″ (blade approximately or 7mm 3/32″ across)

To adjust your cooktop for use with propane gas, follow these instructions:

  1. Disconnect all electrical power, at the main circuit breaker or fuse box.
  2. Shut off the gas supply to the cooktop by closing the manual shut-off valve.

CONVERTING THE PRESSURE REGULATOR

  1. Use an adjustable wrench to unscrew the hex-nut cap from the pressure regulator.
  2. Turn the plastic cap 1/4 turn to disassemble.
  3. Turn the plastic cap over as indicated in the picture. Align the tabs of the plastic cap with the slots of the hex-nut cap. Insert cap and rotate 1/4 turn to reassemble The letters -LP” should now be visible on the top of the plastic cap.
  4. Screw the hex-nut cap back onto the pressure regulator.

GE APPLIANCES JGP3030DLWW 30 Built In Gas Cooktop with
Dishwasher

CONVERTING THE COOKTOP BURNERS

A. Remove the top grates, burner caps and burner heads.

GE APPLIANCES JGP3030DLWW 30 Built In Gas Cooktop with Dishwasher -
BURNERS Round bunner

B. Using a 7mm or 9/32″ nut driver, remove the top burner orifices. These may be accessed through the burner opening in the base.
NOTICE: Save these orifices removed from the appliance for future use.
C. Remove the propane orifices from the bracket attached to the regulator. The top surface of the orifice is engraved for identification. Use the table and figure to determine the placement of the propane orifices.

GE APPLIANCES JGP3030DLWW 30 Built In Gas Cooktop with Dishwasher - BURNERS
2

JGP3530 – BURNER OUTPUT RATINGS: BTU/HR

Propane Gas 10” W.C.P.
BURNER| BTU RATE| ORIFICE SIZE (mm)| MARKING
LF| 18.000| 1.| 125L
LR| 5.000| 0.66| 66L
RR| 12.000| 1.| 102L
RF| 9.500| 0.91| 91L

JGP3530 – BURNER OUTPUT RATINGS: BTU/HR BURNER BTU RATE ORIFICE SIZE (mm) MARKING LF 18.000 1.25 125L LR 5.000 0.66 66L RR 12.000 1.02 102L RF 9.500 0.91 91L
JGP3030, PGP6030. CGP6030 – BURNER OUTPUT RATINGS: BTU/HR BURNER BTU RATE ORIFICE SIZE (mm) MARKING LF 15.000 1.15 115L LR 5.000 0.66 66L RR 12.000 1.02 102L RF 9.500 0.91 91L

JGP3030, PGP6030. CGP6030 – BURNER OUTPUT RATINGS: BTU/HR

Propane Gas 10” W.C.P.
BURNER| BTU RATE| ORIFICE SIZE (mm)| MARKING
LF| 15.000| 1.| 115L
LR| 5.000| 0.66| 66L
RR| 12.000| 1.| 102L
RF| 9.500| 0.91| 91L

D. Using a 7mm or 9/32″ nut driver, install the propane orifices in their precise locations. To prevent leakage, make sure the orifices are securely screwed into the gas injets. E. Install the old orifices into the metal bracket along with these instructions, and replace onto the regulator for possible future conversion.

CHECK SURFACE BURNERS

Push and turn a knob to the LITE position. A clicking sound indicates proper operation of the ignition system. When lighting any burner, sparks will appear at all burners but gas flows from only the one selected. Once air is purged from the supply line, burner should light within 4 seconds. After burner lights, rotate the knob out of the LITE position. Try each burner in succession until all burners have been checked.
Quality of Flames
Determine the quality of flames visually. Normal burner flames should look like (A) or (B).GE APPLIANCES JGP3030DLWW 30 Built In Gas Cooktop with
Dishwasher - Flames Long, bright yellow flames are not normal. Normal flames may show signs of an orange tint when well heated or signs of flickering orange due to particles in the gas or air.
ADJUSTING LOW FLAME SETTING ON COOKTOP BURNERS
Low setting adjustments must be made with 2 other burners in operation on a medium setting. This procedure prevents the low flame from being set too low, resulting in the flame being extinguished when other burners are turned on.
A. Turn on surface burners to medium setting.
B. Turn the knob on the burner being adjusted to “LO”.
C. Remove the knob and insert a small flat blade screwdriver in the valve shaft as shown. Turn clockwise as far as possible while maintaining a stable flame. Repeat for all valves. D. If flame appears too low or unstable, slowly turn adjustment screw counterclockwise until a stable flame exists for each burner.
E. Additionally, for each burner being adjusted, quickly open and close the cabinet doors while observing the flame. If flame is extinguished, turn adjustment screw counterclockwise for a larger flame. Repeat door openings until flame is stable.
SPECIAL NOTE: To convert the cooktop back to natural gas, reverse the instructions given in making propane adjustments.
NOTICE: Once the conversion is complete and confirmed, fill out the propane sticker and include your name, organization and date conversion was made. Apply the sticker to the cooktop near the regulator to alert others in the future that this appliance has been converted to propane. If converting back to natural gas from propane, please remove the sticker so others know the appliance is set to use natural gas.

ADDITIONAL INFORMATION

JGP3530 – BURNER OUTPUT RATINGS: BTU/HR

NG (Natural) Gas 5” W.C.P.
BURNER| BTU RATE| ORIFICE SIZE (mm)| MARKING
LF| 18.000| 1.93| 193N
LR| 5.000| 0.97| 97N
RR| 12.000| 1.52| 152N
RF| 9.500| 1.33| 133N
JGP3030, PGP6030, CGP6030  – BURNER OUTPUT RATINGS: BTU/HR

NG (Natural) Gas 5” W.C.P.
BURNER| BTU RATE| ORIFICE SIZE (mm)| MARKING
LF| 15.000| 1.73| 173N
LR| 5.000| 0.97| 97N
RR| 12.000| 1.52| 152N
RF| 9.500| 1.33| 133N

GE APPLIANCES JGP3030DLWW 30 Built In Gas Cooktop with Dishwasher - Flames
2

PROPANE CONVERSION INSTRUCTIONS
31-2001092 Rev. 1 11-22 GEA
JGP3530, JGP3030, PGP6030, CGP6030

Documents / Resources

| GE APPLIANCES JGP3030DLWW 30 Built In Gas Cooktop with Dishwasher [pdf] Instructions
JGP3030DLWW 30 Built In Gas Cooktop with Dishwasher, JGP3030DLWW, 30 Built In Gas Cooktop with Dishwasher, Cooktop with Dishwasher, Dishwasher
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

GE Appliances User Manuals

Related Manuals