U-LINE OCP115 15 Inch Clear Ice Machine User Guide
- June 12, 2024
- U-Line
Table of Contents
QUICK START GUIDE
15“ Clear Ice Machines
115 V / 60 Hz
OCP115 15 Inch Clear Ice Machine
WELCOME TO U-LINE
Congratulations on your U-Line purchase. Your product comes from a company
with over five decades of premium modular ice making, refrigeration, and wine
preservation experience. U-Line continues to be the American leader,
delivering versatility and flexibility for multiple applications including
residential, light commercial, outdoor and marine use. U-Line’s complete
product collection includes Wine Captain® Models, Beverage Centers, Clear Ice
Machines, Nugget Ice Machines, Crescent Ice Makers, Glass & Solid Door
Refrigerators, Drawer Models, Freezers, Combo® Models, and more.
U-Line has captivated those with an appreciation for the finer things with
exceptional functionality, style, inspired innovations and attention to even
the smallest details. We are known and respected for our unwavering dedication
to product design, quality and selection. U-Line is headquartered in
Milwaukee, Wisconsin and has shipped product to five continents for over two
decades and is proud to have the opportunity to ship to you. U-Line – RIGHT
PRODUCT. RIGHT PLACE. RIGHT TEMPERATURE®.
PRODUCT INFORMATION
Looking for additional information on your product? User Guides, Spec Sheets,
CAD Drawings, Compliance Documentation, and Product Warranty information are
all available for reference and download at
u-line.com.
PROPERTY DAMAGE / INJURY CONCERNS
In the unlikely event property damage or personal injury is suspected related
to a U-Line product, please take the following steps:
- U-Line Customer Care must be contacted immediately at +1.414.354.0300.
- Service or repairs performed on the unit without prior written approval from U-Line is not permitted. If the unit has been altered or repaired in the field without prior written appr val from U-Line, claims will not be eligible.
GENERAL INQUIRIES
U-Line Corporation
8900 N. 55th Street
Milwaukee, Wisconsin 53223 USA
Monday – Friday 8:00 am to 4:30 pm CST
T: +1.414.354.0300
Email: sales@u-line.com
u-line.com
SERVICE & PARTS ASSISTANCE
Monday – Friday 8:00 am to 4:30 pm CST
T: +1.414.354.0300
Service Email: onlineservice@u-line.com
Parts Email: onlineparts@u-line.com
CONNECT WITH US
Designed, engineered and assembled in WI, USA
This Quick Start Guide covers the basics of installation and general use of
your product. For more details, see the complete User Guide & Service Manual
on u-line.com.
This product is eligible for an additional one-year warranty at no charge when
you register your product on u-line.com.
See complete warranty for details.
Safety and Warning
NOTICE
Please read all instructions before installing, operating, or servicing the
appliance.
Use this appliance for its intended purpose only and follow these general
precautions with those listed throughout thisguide:
SAFETY ALERT DEFINITIONS
Throughout this guide are safety items labeled with a Danger, Warning, or
Caution based on the risk type:
DANGER!
Danger means that failure to follow this safety statement will result in
severe personal injury or death.
WARNING!
Warning means that failure to follow this safety statement could result in
serious personal injury or death.
CAUTION!
Caution means that failure to follow this safety statement may result in minor
or moderate personal injury, property, or equipment damage.
DANGER!
This unit contains R600a (Isobutane) which is a flammable hydrocarbon. It is
safe for regular use. Do not use sharp objects to expedite defrosting. Do not
service without consulting the “R600a specifications” section included in the
User Guide. Do not damage the refrigerant circuit.
WARNING!
Service must be done by factory authorized service personnel. Any parts shall
be replaced with like components. Failure to comply could increase the risk of
possible ignition due to incorrect parts or improper service.
CALIFORNIA PROPOSITION 65
This product contains chemicals known to the state of California to cause
cancer and birth defects or other reproductive harm.
www.P65warnings.CA.gov
CAUTION!
This equipment is to be installed with adequate backflow protection to comply
with applicable federal, state and local codes.
Environmental Requirements
INDOOR UNITS
This model is intended for indoor/interior applications only and is not to be
used in installations that are open/exposedto natural elements. This unit is
designed to operate between 50°F (10°C) and 100°F (38°C). Higher ambient
temperatures may reduce the unit’s ability to reach low temperatures and/or
reduce ice production on applicable models.
For best performance, keep the unit out of direct sunlight and away from heat
generating equipment.
In climates where high humidity and dew points are present, condensation may
appear on outside surfaces.
This is considered normal. The condensation will evaporate when the humidity
drops.
CAUTION!
Damages caused by ambient temperatures of 40°F (4°C) or below are not covered
by the warranty.
OUTDOOR UNITS
This unit is designed to operate between 50°F (10°C) and 100°F (38°C). Higher
ambient temperatures may reduce the unit’s ability to reach low temperatures
and/or reduce ice production on applicable models.
For best performance, keep the unit out of direct sunlight and away from heat
generating equipment.
In climates where high humidity and dew points are present, condensation may
appear on outside surfaces. This is considered normal. The condensation will
evaporate when the humidity drops.
CAUTION!
Damages caused by ambient temperatures of 40°F (4°C) or below are not covered
by the warranty.
Electrical
WARNING!
SHOCK HAZARD — Electrical Grounding Required. Never attempt to repair or
perform maintenance on the unit until the electricity has been disconnected.
Never remove the round grounding prong from the plug and never use a two-prong
grounding adapter.
Altering, cutting or removing power cord, removing power plug, or direct
wiring can cause serious injury, fire, loss of property and/or life, and will
void the warranty.
Never use an extension cord to connect power to the unit.
Always keep your working area dry.
NOTICE
Electrical installation must observe all state and local codes. This unit
requires connection to a grounded (three-prong), polarized receptacle that has
been placed by a qualified electrician.
The unit requires a grounded and polarized 115 VAC, 60 Hz, 15A power supply
(normal household current). An individual, properly grounded branch circuit or
circuit breaker is recommended. A GFCI (ground fault circuit interrupter) is
usually not required for fixed location appliances and is not recommended for
your unit because it could be prone to nuisance tripping. However, be sure to
consult your local codes.
See CUTOUT & PRODUCT DIMENSIONS for recommended receptacle location.
Water Hookup
PREPARE PLUMBING
The water valve uses a standard 1/4” (6.35 mm) compression fitting.
U-Line recommends using accessory water hookup kit – Part # 80-54674-00. The
kit includes a 10’ (3 m) braided flexible water supply line and a brass hose
fitting.
WARNING!
Prior to installation, determine if this product contains a gravity style
drain or factory installed drain pump. Products without a drain pump may only
use a gravity style drain. Failure to connect water supply or drain line
connections properly may result in water leakage, personal injury, and/or
property damage. Disconnect power and turn off water to the unit before
attempting to alter these connections. These connections are the
responsibility of the owner and must be connected per local plumbing code. If
you are uncertain of how to safely and properly install this product, contact
a licensed plumber.
Water Supply Connection
WARNING!
Connect to potable water supply only.
CAUTION!
Review, obey, and understand the local plumbing codes before you install your
unit. Connect to the cold water supply. The water pressure should be between
20 and 120 psi (138 and 827 kPa). The water line MUST have a shutoff valve on
the supply line.
CAUTION!
Do not use any plastic water supply line. The line is under pressure at all
times. Plastic may crack or rupture with age and cause damage to your home.
Do not use tape or joint compound when attaching a braided flexible water
supply line that includes a rubber gasket. The gasket provides an adequate
seal – other materials could cause blockage of the valve.
Failure to follow recommendations and instructions may result in damage and/or
harm, flooding or void the product warranty.
CAUTION!
Turn off water supply and disconnect electrical supply to unit prior to
installation.
Use caution when handling back panel. The edges could be sharp.
-
Turn off water supply and disconnect electrical supply to product prior to attempting installation.
-
Remove the grille/access panel in the front and the back panel.
-
Locate water valve in the front of the unit and thread water supply line through. NOTICE
Route the water supply line through the unit so it does not come into contact with any internal components other than the solenoid valve. Normal operation creates some vibration. A water supply line contacting an internal component or cabinet wall can cause excessive noise during operation or damage to the line. -
On the back panel, break away filler feature in bushing with flat screwdriver.
-
Thread water line through back panel hole (with bushing) and connect to cold water supply line.
-
Turn on water supply and check for leaks.
-
Reinstall back panel and grille/front access panel.
-
Install retaining clip.
Drain
Model numbers including “-00” or “-07” do not include a factory installed
drain pump.
Model numbers including “-40” or “-47” include a factory installed drain pump.
DRAIN CONNECTION
CAUTION!
If your U-Line unit did not come with a factory installed drain pump you must
use a gravity style drain connection. For assistance in determining if your
unit has a pump please contact U-Line. The floor drain must be large enough to
accommodate drainage from all attached drains. Follow these guidelines when
installing drain lines to prevent water from flowing back into the ice maker
storage bin and/ or potentially flowing onto the floor, which may result in
personal injury or property damage.
NOTICE
Drain can NOT be located directly below the unit.
Unit has a solid base that will not allow the unit to drain below itself.
There is a possibility that hose connections may have loosened during
shipment.
Verify all connections and fittings are free from leaks.
GRAVITY DRAIN
A
gravity drain may be used if:
Drain line has at least a 1″ drop per 48″ (approximately 2 cm drop per 100 cm)
of run.
Drain line does not create traps and is vented per local code.
- Cut the pre-installed drain tube to length.
- Connect to your local plumbing per the local code.
- If necessary, insulate drain line to prevent condensation.
CAUTION!
Failure to connect water supply or drain line connections properly can result
in personal injury and property damage. Gravity drain connections must be
routed downward from the rest of the unit at the rate of 1/4″ per foot (1 cm
per 50 cm).
FACTORY INSTALLED DRAIN PUMP
If your drain line will run up to a stand pipe, disposal or spigot assembly,
or does not otherwise meet the requirements for a gravity drain, you may have
ordered a pre-installed U-Line P60 drain pump.
If you need to install a P60 drain pump into your unit, see DRAIN PUMP section
in the User Manual.
See below for typical installations requiring a drain pump.
Stand Pipe
P60 Pump Required
Disposal Assembly
P60 Pump Required
Y-Branch Tailpiece
P60 Pump Required
NOTICE
The maximum lift for the P60 drain pump is 10 feet. This must be done as close
to the rear of the unit as possible.
Door Swing
Units have a zero clearance for the door to open 90°, when installed adjacent
to cabinets.
Stainless Steel and black and white models require 2-1/8″ (54 mm) door
clearance to accommodate the handle if installed next to a wall.
Integrated models require 1/4″ (6 mm) clearance if installed next to a wall.
Allow for additional space for any knobs or pulls installed on the integrated
panel/frame.
Door Adjustments
HINGE COVER
Hinge cover included with the literature bag is optional.
To install hinge cover:
- Press hinge cover squarely over hinge.
DOOR ALIGNMENT AND ADJUSTMENT
Align and adjust the door if it is not level or is not sealing properly. If
the door is not sealed, the unit may not cool properly, or excessive frost may
form in the interior.
NOTICE
Properly aligned, the door’s gasket should be firmly in contact with the
cabinet all the way around the door (no gaps). Carefully examine the door’s
gasket to ensure that it is firmly in contact with the cabinet. Also make sure
the door gasket is not pinched on the hinge side of the door.
To align and adjust the door:
- Gently pry off hinge c ver from top of unit.
- Loosen (do not remove) top and bottom hinge screws using a Torx T-25 screwdriver on the top and a 1/4” socket on the bottom.
- Align door squarely with cabinet.
- Make sure gasket is firmly in con act with cabinet all the way around the door (no gaps).
- Tighten bottom hinge screws.
- Tighten top hinge screws and replace hinge cover.
REVERSING THE DOOR
Location of the unit may make it desirable to mount the door on the opposite
side of the cabinet.
The hinge hardware will be removed and reinstalled on the opposite side of the
cabinet.
TO REVERSE THE DOOR
Remove arrow clips:
- With a putty knife or other flat tool, gently pry eac arrow clip from hinge mounting holes.
- Set aside arrow clips to be reused on the opposite side.
Remove top hinge and door:
- Remove hinge cover from top of unit
- Hold door to keep it from falling.
- Remove top hinge from cabinet using a Torx T-25 screwdriver to remove three screws.
- Remove door by tilting forward and lifting door off bottom hinge. Retain shoulder washers; they will be reused.
- Insert arrow clips into holes
Remove bottom hinge:
- Remove bottom hinge from cabinet using a 1/4” socket.
- Remove corresponding screws on opposite side of cabinet. On some models there may be a nut behind one or both screws on either side.
Install bottom hinge:
Install two or three screws, depending on model. Replace nuts if used.
PREPARE DOOR FOR REINSTALLATION
Rotate gasket
- With a flat tool, such as putty knife, gently pry up beneath the gasket and spacer until completely free from the door surface.
- Continue removing the gasket by grabbing hold and gently pulling outward, exposing the gasket channel.
- Remove the 3 pieces of gasket channel filler and reinstall on the opposite end of door.
- Install gasket into channel, beginning at one corner and pressing in firmly.
- Press down on middle horizontal portion of gasket until it adheres to the door surface.
Note: It may be necessary to apply a strip of two-sided tape for a firm
adhesion.
Install top hinge and door:
- Remove pivot screw from hinge, flip hinge ver, and install the pivot screw in the same hole from the opposite surface.
- Lift the door onto the bottom hinge.
- Align edge of the hinge with the outer edge of the unit.
- Tighten three screws and replace hinge cover.
- Replace hinge cover.
Align and adjust the door:
Align and adjust the door (see DOOR ALIGNMENT AND ADJUSTMENT)
General Installation
LEVELING INFORMATION
- Use a level to confirm the unit is level. Level should be placed along top edge and side edge as shown.
- If the unit is not level, adjust the legs on the corners of the unit as necessary.
- Confirm the unit is level after each adjustment and repeat the previous steps until the unit is level.
INSTALLATION TIP
If the room floor is higher than the floor in the cutout opening, adjust the
rear legs to achieve a total unit rear height of 1/8″ (3 mm) less than the
opening’s rear height. Shorten the unit height in the front by adjusting the
front legs. This allows the unit to be gently tipped into the opening.
Readjust the front legs to level the unit after it is correctly positioned in
the opening.
INSTALLATION
- Plug in the power/electrical cord.
- Gently push the unit into position. Be careful not to entangle the cord or water and drain lines.
- Re-check the leveling, from front to back and side to side. Make any necessary adjustments. The unit’s top surface should be approximately 1/8″ (3 mm) below the countertop.
- Install the anti-tip bracket.
- Remove interior packing material and wipe out the inside of the unit with a clean, water-dampened cloth.
Anti-Tip Bracket
-
Slide unit out so screws on top of unit are easily accessible.
-
Remove the two screws from the opposite side of the hinge assembly using a T-25 Torx driver (see below).
NOTE: 1224 models shown with four screw. 1215 models only have three screws, but same screws are used in both applications. -
Place bracket (part #14154) over holes and attach to unit with two screws removed in step 2 using a T-25 Torx driver. Tighten screws fully.
-
Gently push unit into position. Be careful not to entangle the electrical cord or water line, if applicable.
-
Check to be sure the unit is level from front to back and side to side. Make any necessary adjustments. The unit’s top surface should be approximately 1/8″ (3 mm) below the countertop.
-
Secure bracket into adjoining surface.
Integrated Panel Installation
-
Fully open door.
-
Starting at corner, pull gasket away from door.
-
Continue to pull gasket free from gasket channel.
-
Upon removal, lay gasket down on a flat surface.
-
Partially loosen the 3 screws, securing the top hinge to the cabinet.
-
Align the panel with the outside edge (opposite the hinge) and high enough to align with the highest point in the door.
-
Insert panel underneath top hinge and apply upward pressure while bringing the lower portion of the panel flush to the door inside the lower hinge. The panel will fit snuggly.
-
Align door with cabinet. Tighten the top 3 screws, securing the top hinge to the cabinet.
Align Top Of Panel With Highest Point Of Door NOTICE
Due to differences in floor construction or surrounding cabinetry, the panel may not sit flush with the top of the door. -
Secure integrated panel to door using clamps. A robust tape may also be used. U-Line recommends the use of bar clamps to secure the panel to the door. If using tape, be certain the tape will not damage panel finish upon removal.
-
Using a 7/64″ (3 mm) drill bit, drill 6 pilot holes into the wood panel 1/2″ (12 mm) deep using the holes in the door frame as a guide.
NOTICE
It is important to ensure that all drilled holes are drilled to the correct depth in order to avoid splits in the wood when hardwood is installed. -
Locate 6 of the #6x 1-1/4″ (32 mm) screws provided with your unit.
-
Using a Phillips screwdriver, place one screw into each of the 6 pilot holes and screw down. Do not overtighten screws.
-
Be sure the screws force their way past the opening on the gasket channel and sit flush against the bottom of the channel.
-
Remove clamps from door.
NOTICE
If panel requires additional adjustment after removing clamps, slightly loosen each screw and adjust panel as necessary. Tighten screws upon completion. -
Starting at the corners, re-install the gasket into the gasket channel in the frame. Make sure the gasket is fully seated. This may take some force.
Control Operation
CONTROL FUNCTION GUIDE
FUNCTION | COMMAND | NOTES |
---|---|---|
ON/OFF | Press and release | Unit will immediately turn On or OFF |
Adjust ice thickness | See “Ice” section | |
Enable Sabbath Mode | Press and hold for 5 seconds and release | The °F / °C |
symbol will flash briefly after 5 secon .
Interior light and display will go dark and remain so until user resets mode –
unit continues to operate
Disable Sabbath Mode| Press and release| Display and interior light return to
normal operation
Silent Mode (ice production suspended for 3 hours)| Hold and | Display will
countdown the hours:
Clean Mode| See “Cleaning” section|
Showroom Mode| Hold and for 5 seconds| The °F / °C symbol will flash. Displ y
will be lit and interior light will function. Unit will not cool. Repeat
command to return to normal operation
This unit is Star-K certified. See www.star-k.org for more details.
First Use
All U-Line controls are preset at the factory. Initial startup requires no
adjustments. See CONTROL OPERATION section for more details.
NOTICE
U-Line recommends discarding the ice produced during the first two to three
hours of operation to avoid possible dirt or scale that may dislodge from the
water line.
When plugged in, the unit will begin operating under the factory default
settings. If the unit was turned off during installation, simply press and the
unit will immediately switch on. To turn the unit off, press and release.
Airflow and Product Loading
NOTICE
The unit requires proper airflow to perform at its highest efficiency. Do not
block the front grille at any time, or the unit will not perform as expected.
Do not install the unit behind a door.
Ice
ICE CUBE THICKNESS ADJUSTMENT
NOTICE
Ice thickness adjustment should only be made one increment at a time. Allow
ice maker production to stabilize for 24 hours before rechecking ice
thickness.
Ice is produced in layers resulting in a clear cube. Ice in bin may develop
surface frost which disappears when cube is placed in liquid.
Ice cubes in any given batch will vary, so it is necessary to choose cubes
from the sample area for comparison when making adjustments.
The ice cube thickness is factory set for best overall performance. The
factory setting is designed to maintain an ice bridge of approximately 1/16″
to 1/8″ (1.6 mm to 3.2 mm) under normal conditions, resulting in a dimple of
approximately 1/4″ to 1/2″ (6.4 mm to 12.7 mm) in depth. A fuller cube with
less of a dimple results in a thicker ice bridge. As the ice bridge becomes
thicker, the tendency for the cubes to stay together as a slab increases. A
bridge thicker than 1/8″ (3.2 mm) may cause cubes to overfill the ice bucket.
32 ice cubes are formed on a 4 x 8 slab during each cycleEach cycle takes
approximately 15-20 minutes at the default cube thickness (0).
Your clear ice machine is pre-set to produce ice between the optimal dimensions illustrated below:
Ice thickness adjustments are made using the control panel as follows:
- To enter the thickness adjustment mode:
• Press and hold for 5 seconds.
• The display will switch to “0” to confirm the thickness adjustment mode has been selected.
The factory setting is “0”. Use to raise the setting and thicken the ice
bridge, or to lower the setting to thin the ice bridge.
Ice cubes in any given batch will vary, so it is necessary to choose cubes
from the sample area for comparison when making adjustments.
Cleaning
EXTERIOR CLEANING
Vinyl Clad (Black or White) Models
Clean surfaces with a mild detergent and warm water solution. Do not use
solvent-based or abrasive cleaners. Use a soft sponge and rinse with clean
water. Wipe with a soft, clean towel to prevent water spotting.
Clean any glass surfaces with a non-chlorine glass cleaner.
Stainless Models
Stainless door panels, handles and frames can discolor when exposed to
chlorine gas, pool chemicals, saltwater or cleaners with bleach.
Keep your stainless unit looking new by cleaning with a good quality all-in-
one stainless steel cleaner and polish monthly. For best results use Claire®
Stainless Steel Polish and Cleaner. Comparable products are acceptable.
Frequent cleaning will remove surface contamination that could lead to rust.
Some installations may require cleaning weekly.
Do not clean with steel wool pads.
Do not use stainless steel cleaners or polishes on any glass surfaces.
Clean any glass surfaces with a non-chlorine glass cleaner.
Do not use cleaners not specifically intended for stainless steel on stainless
surfaces (this includes glass, tile and counter cleaners).
If any surface discoloring or rusting appears, clean it quickly with Bon-Ami®
or Barkeepers Friend Cleanser® and a nonabrasive cloth. Always clean with the
grain. Always finish with Claire® Stainless Steel Polish and Cleaner or
comparable product to prevent further problems.
Using abrasive pads such as ScotchBrite™ will cause the graining in the
stainless steel to become blurred.
Rust not cleaned up promptly can penetrate the surface of the stainless steel
and complete removal of the rust may not be possible.
Integrated Models
To clean integrated panels, use household cleaner per the cabinet
manufacturer’s recommendations.
INTERIOR CLEANING
Disconnect power to the unit.
Clean the interior and all removed components using a mild nonabrasive
detergent and warm water solution applied with a soft sponge or non-abrasive
cloth.
Rinse the interior using a soft sponge and clean water.
Do not use any solvent-based or abrasive cleaners. These types of cleaners may
transfer taste and/or odor to the interior products and damage or discolor the
interior.
CLEAR ICE MACHINE CLEANING CYCLE
Your U-Line clear ice machine has an automatic clean alert function. Cleaning
cycles should be run as notified. Otherwise, to maintain operational
efficiency the unit should be cleaned every three months. Depending on water
conditions, more frequent cleaning may be necessary. If the ice machine
requires more frequent cleaning, consult a plumber to test the water quality
and recommend appropriate treatment.
CAUTION!
Wear rubber gloves and safety goggles and/or face shield when handling Ice
Machine Cleaner.
NOTICE
Use only U-Line Ice Machine Cleaner (Part No. 37050, available from your
dealer or direct from your local parts distributor. To locate a parts
distributor near you, visit www.u-line.com. It is a violation of federal law
to use this solution in a manner inconsistent with its labeling. Use of any
other cleaner can ruin the finish of the evaporator and will void the
warranty. Read and understand all labels printed on the package before use.
U-Line Ice Machine Cleaner is used to remove lime scale and other mineral
deposits. Refer to the following steps to initiate the self-cleaning cycle.
CAUTION!
Never use anything to force ice from the evaporator. Damage may result.
-
Turn the ice machine off and allow any ice to melt off of the evaporator.
-
Remove all ice from the storage bin.
-
Remove evaporator cover.
-
Remove the standpipe by lifting it up while using a slight back and forth motion to loosen it from the drain hole. The water in the reservoir will flow down the drain.
-
Re-install the standpipe into the water trough.
-
Clean the Interior Bin as follows:
• Dilute one packet of CLR cleaner into two quarts of water.
• Using a sponge or cloth, clean interior of ice bin, tubing and door. This cleaner will remove all mineral deposits and other contaminants from the surfaces.
• Using a bottle brush, clean out the trough drain tube and pump tubing where needed. -
Turn unit on by pressing .
-
Place the unit into CLEAN mode by holding for 5 seconds.
-
When water begins flowing over the evaporator (approximately 3 minutes), pour 1 packet of CLR cleaner into the water trough. The cleaning process will last approximately 45 minutes.
-
Dilute 1 tablespoon bleach in 1 gallon of warm water. Apply this solution to the entire inside of the storage area. Then rinse thoroughly with water.
The unit will resume operation approximately 15 minutes after the automated
cleaning process is completed. The water fill valve will energize, fill the
water reservoir, and shut-off after three minutes. The compressor begins to
operate and water flows over the evaporator assembly (ice mold). Initially,
the water flow may not be uniform, causing uneven sized cubes or water to
spill into the ice storage bin. This is a normal situation that will correct
itself within the first 24 hours of operation.
NOTICE
Discard all ice produced in the first harvest.
Should power to the unit be interrupted during the self-clean cycle, it will
be necessary to repeat the complete cleaning cycle after power is restored.
REFRESH KIT
Due to variations in water quality or inadequate maintenance your unit may
become excessively coated in lime scale or calcium. U-Line offers a cost
effective refresh kit which replaces many interior components and will return
your unit to like new condition. Refresh kits may be ordered from your local
distributor and installed by your local service company. For information on
your local distributor or service company please visit
www.u-line.com.
U-Line Corporation (U-Line) Limited Warranty
One Year Limited Warranty
For one year from the date of original purchase, this warranty covers all
parts and labor to repair or replace any part of the product that proves to be
defective in materials or workmanship. For products installed and used for
normal residential use, material cosmetic defects are included in this
warranty, with coverage limited to 60 days from the date of original purchase.
All service provided by U-Line under the above warranty must be performed by a
U-Line factory authorized servicer, unless otherwise specified by U-Line.
Service provided during normal business hours.
Two Year Limited Warranty (5 Class Product)
For two years from the date of original purchase, this warranty covers all
parts and labor to repair or replace any part of the product that proves to be
defective in materials or workmanship. For products installed and used for
normal residential use, material cosmetic defects are included in this
warranty, with coverage limited to 60 days from the date of original purchase.
All service provided by U-Line under the above warranty must be performed by a
U-Line factory authorized servicer, unless otherwise specified by U-Line.
Service provided during normal business hours.
Available Second & Third Year Limited Warranty
In addition to the standard one and two year warranties outlined above, U-Line
offers a one year extension of the warranties from the date of purchase, free
of charge. To take advantage of this extension, you must register your product
with U-Line within 60 days from the date of purchase at u-line.com and provide
proof of purchase. Nugget Ice Machine proof of purchase must include the
purchase of an in-line water filter and filter head to qualify for this
additional limited warranty.
Five Year Sealed System Limited Warranty
For five years from the date of original purchase, U-Line will repair or
replace the following parts, labor not included, that prove to be defective in
materials or workmanship: compressor, condenser, evaporator, drier, and all
connecting tubing. All service provided by U-Line under the above warranty
must be performed by a U-Line factory authorized servicer, unless otherwise
specified by U-Line. Service provided during normal business hours.
Terms
These warranties apply only to products installed in any one of the fifty
states of the United States, the District of Columbia, or the ten provinces of
Canada. The warranties do not cover any parts or labor to correct any defect
caused by negligence, accident or improper use, maintenance, installation,
service, repair, acts of God, fire, flood or other natural disasters. The
product must be installed, operated, and maintained in accordance with your
product’s User Guide.
The remedies described above for each warranty are the only ones that U-Line
will provide, either under these warranties or under any warranty arising by
operation of law. U-Line will not be responsible for any consequential or
incidental damages arising from the breach of these warranties or any other
warranty, whether express, implied, or statutory. Some states do not allow the
exclusion or limitation of incidental or consequential damages, so the above
limitation or exclusion may not apply to you. These warranties give you
specific legal rights, and you may also have other rights which vary from
state to state.
Any warranty that may be implied in connection with your purchase or use of
the product, including any warranty of merchantability or any warranty fit for
a particular purpose is limited to the duration of these warranties, and only
extends to five years in duration for the parts described in the section
related to the five year limited warranty above. Some states do not allow
limitations on how long an implied warranty lasts, so the above limitations
may not apply to you.
- The warranties only apply to the original purchaser and are non-transferable.
- The second, third, and five year warranties cover products installed and used for normal residential or designated marine use only.
- The warranties apply to units operated outside only if designed for outdoor use by model and serial number.
- U-Line Commercial products are covered by the one year and 5 year limited warranties and are not eligible for the second and third year limited warranties.
- Replacement water filters, light bulbs, and other consumable parts are not covered by these warranties.
- The start of U-Line’s obligation is limited to four years after the shipment date from U-Line.
- In-home instruction on how to use your product is not covered by these warranties.
- Food, beverage, and medicine loss are not covered by these warranties.
- If the product is located in an area where U-Line factory authorized service is not available, you may be responsible for a trip charge or you may be required to bring the product to a U-Line factory authorized service location at your own cost and expense.
- Units purchased after use as floor displays, and/or certified reconditioned units, are covered by the limited one year warranty only and no coverage is provided for cosmetic defects.
- Signal issues related to Wi-Fi connectivity are not covered by these warranties.
For parts and service assistance, or to find U-Line factory
authorized service near you, contact U-Line:
8900 N. 55th Street, Milwaukee, WI 53223
u-line.com
onlineservice@u-line.com
+1.414.354.0300
Copyright U-Line Corporation.
All Rights Reserved.
Publication Number 30379
11/2022 Rev. P
Documents / Resources
|
U-LINE OCP115 15 Inch Clear Ice
Machine
[pdf] User Guide
UOCL115SS01B, OCP115 15 Inch Clear Ice Machine, 15 Inch Clear Ice Machine,
Clear Ice Machine, Ice Machine
---|---
References
- BestShop | Best Price, Smart Shopping
- P65warnings.CA.gov
- Kosher Certificates | Kosher Certification | STAR-K
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>