Antari Z-1500 III Stage Fog Machine User Manual

June 12, 2024
Antari

Antari Z-1500 III Stage Fog Machine User Manual

Antari Z-1500 III Stage Fog Machine User Manual

Antari Z-logo

User Manual

Introduction

Please read all the user manual before operating the machine, and place the manual where the user can refer to it at all time. The manual includes how to install and operate the machine under safe condition and explain all the labels printed on the machine. If you encounter any problem, contact your local Antari dealer for assistant immediately.

Safety Information

Antari Z-1500 III Stage Fog Machine - Safety
information

DANGER

  • Must connect the machine to the correct rated voltage or it might lead to an electrical shock or a burn and may cause serious consequences.
  • Must connect the machine to a protected circuit and ensure it is properly grounded to avoid the risk of electrocution. For grounding instruction, please refer to Appendix I on page 21.
  • Do not operate the machine with a bundled power cord, it could lead to a fire hazard.
  • When operating the machine, do not point at people, animals, or fire.

WARNING

  • Machine’s nozzle is extremely hot, please keep at least 50cm distance from the nozzle when the machine is running.
  • Please operate the machine on a flat, level hard and well ventilated surface area, reserve at least 50cm space around the machine and make sure there is no flammable gas or material nearby.
  • Do not disassemble, repair or modify the machine, it may cause damages, malfunction, risk of electrical shock or result in fire.
  • The machine can only be operated by adults or professionals, is not intended for use by person with reduced physical sensory, mental capabilities, or lack of experience and knowledge including children.
  • Do not leave the machine running unattended, make sure all powers are off when leaving.
  • Children should be supervised to ensure that they do not play with the machine.
  • Do not use the machine upside down or tilt it, it might cause damages or malfunction.
  • Please store the fluid inside in a well ventilated area without direct sunlight and keep out of reach of children.
    In case of eye contact or accidentally swallow the fluid, please seek medical attention immediately.

CAUTION

  • Keep the machine dry at all time. The machine is not waterproof, do not expose the machine to water, rain, or moisture environment.
  • Please make sure the power outlet is not damaged or loose before plug in the power cord.
  • If the power cord is damaged, it must be replaced by Antari or its local dealers, otherwise the warranty will be void.
  • Before operating the machine, please sure the fluid is filled in the fluid tank to avoid the pump in idling state which could lead to overeat or malfunction.
  • Before transporting the machine, please make sure the fluid is drained and tank is empty. (Recommend using original package)
  • The machine is for indoor use only.
  • Do not operate the machine in any area with unstable voltage.
  • If you experience strange sound or malfunction, turn off the power and unplug the power cord immediately and contact your local Antari dealer for assistant.
  • Do not contact any moving part.
  • Only use accessories recommended or sold by Antari.
  • Please make sure the power is off when not using the machine and unplug the power cord if not intend to use for a long period of time.
  • To disconnect, turn all controls to the off position, then remove plug from outlet.
  • Do not unplug by pulling on cord. To unplug, grasp the plug, not the cord.
  • Unplug from outlet before servicing or cleaning.
  • Do not operate the machine with a damaged cord or plug, or after the machine malfunctions or is dropped or damaged in any manner. Return machine to the nearest authorized service facility for examination, repair, or electrical or mechanical adjustment.
  • To ensure the lifespan of the machine, please only use the fluid manufactured by Antari, do not use other fluid or additive, otherwise it may clog the heater and cause malfunction.

Before operating the machine, please read all warning labels on the machine, description as below;

Top Cover Printing
WARNING!
HOT NOZZLE!
KEEP AT LEAST 50 CM DISTANCE

LIQUID
ONLY USE MANUFACTURER DESIGNATED FLUID.

Front Cover Printing
WARNING!
DISCONNECT POWER BEFORE CHANGING FUSE
USE ONLY WITH ADULT SUPERVISION
DO NOT OPERATE WITHOUT LIQUID
FOR INDOOR USE ONLY. KEEP DRY
NO USER SERVICEABLE PARTS INSIDE

Package Contents & Inspection

3.1 Package Contents
Immediately upon receiving the machine, carefully unpack the carton, check the content to ensure it is the correct model and all parts are included. If any part appears to be damaged or missing during transportation, please contact your local dealer and return in original package for inspection.

Antari Z-1500 III Stage Fog Machine - Package Contents

3.2 Optional Accessories

Antari Z-1500 III Stage Fog Machine - Optional
Accessories

Machine Details

Antari Z-1500 III Stage Fog Machine - Machine Details

Technical Label Information

Please read the technical label information on the back of the machine before operating it.

Antari Z-1500 III Stage Fog Machine - Technical Label
Information

Fog Fluid

Antari Z-1500 III Stage Fog Machine - Fog Fluid

  • Only the fog fluid manufactured by Antari can be used, do not mix or dilute the fog fluid. Due to improper storage or using other fluid might clog the heater and cause malfunction.
  • The machine is tested and calibrated with the specific fog fluid to get the best performance.
  • Please empty the fluid in the tank before switching to another fluid to avoid mixing.
  • Only the essence manufactured by Antari can be used, and add according to the ratio recommended by Antari (Recommended ratio is 1:1000), if using other essence or different ratio might clog the heater and cause malfunction.
  • The warranty on your fog machine will be void if you use fog fluid not manufacture by Antari.

Setting and Manual Operation

Antari Z-1500 III Stage Fog Machine - Setting and Manual
Operation

Step 1. Place the machine on a flat, level hard and well ventilated surface area and reserve at least 50 cm open space around the machine, and make sure there is no flammable gas or material nearby;
Step 2. Fill the fluid tank with Antari approved fog liquid, and make sure the tube is not twisted;
Step 3. Connect the machine to the power outlet. Please read the technical label on the back of the machine and make sure the power outlet is the correspond to the rated voltage for the machine;
Step 4. Turn on the machine, warm up process takes approximately 10 minutes. Once the machine has reached operating temperature, the LCD display will show “Ready To Fog”. Now the machine is ready for operation;
Step 5. To start fogging in Volume Mode, please press the [VOLUME] knob on the right side of the control panel.
To stop fogging, please press the [VOLUME] knob again. This will run based on “volume” setting in the menu;
Step 6. To start fogging in Timer Mode, please press the [TIMER] knob of the left side of the control panel, to stop fogging press [VOLUME] knob again. This will run based on “interval” & “duration” setting in the menu;
Step 7. To enter the setting menu, press [TIMER] knob and hold for 3 seconds, rotate the [TIMER] knob to scroll through options, press [TIMER] knob to enter the option; rotate the [TIMER] knob to adjust value; press
[TIMER] knob to confirm selection and press [VOLUME] knob to return to the previous page;
Step 8. To turn off the machine, please make sure the machine is not operating then turn of the power. If you will not use the machine a long period of time, please remove the power cord.

Control Settings

Z-1500 III / Z-3000 III Fog Machine can be operated in the following modes. The machine can only accept 1 type of signal at a time.

  • Manual
  • Timer
  • DMX512
  • Wireless
  • Cable Remote

8.1 Control Panel Description

Antari Z-1500 III Stage Fog Machine - Control Panel
Description

Fogging in Volume Mode

Antari Z-1500 III Stage Fog Machine - Fogging in Volume
Mode

Fogging in Timer Mode

Antari Z-1500 III Stage Fog Machine - Fogging in Timer
Mode

Menu and Setting

Antari Z-1500 III Stage Fog Machine - Menu and Setting

8.2 Menu Options Description

Antari Z-1500 III Stage Fog Machine - Menu Options
Description

Machine Status

9.1 Machine Status with LCD Display

Antari Z-1500 III Stage Fog Machine - Machine Status with LCD
Display

**If LCD control panel display “Warning”, please stop operating and turn off the machine immediately. Please contact your local Antari dealer for assistance.

DMX Connection

10.1 DMX Connector Pin Assignment

This machine has a XLR 3-Pin and 5-Pin connector for DMX connection. The diagram below indicates pin assignment information;

Antari Z-1500 III Stage Fog Machine - DMX Connector Pin
Assignment

10.2 DMX Channel Function

Antari Z-1500 III Stage Fog Machine - DMX Channel
Function

RDM Function

Z-1500 III / Z-3000 III Fog Machines are RDM enabled, allowing control system to configure, monitor and manage. See below table for supported RDM parameters.

Antari Z-1500 III Stage Fog Machine - RDM Function

Antari Z-1500 III Stage Fog Machine - RDM Function 2

WTR-20 Wireless Remote (Optional)

WTR-20 Wireless Remote is an optional accessory for Z-1500 III / Z-3000 III Fog Machines, it included a W-2 wireless transmitter and a W-2 wireless receiver. If you already purchased the wireless model, it’s ready to use. If you purchase the WTR-20 Wireless Remote afterwards, please follow the instruction below. If you encounter any problem, please contact your local Antari dealer for assistant.

12.1 W-2 Wireless Transmitter & Receiver

  • Battery:27A 12V
  • Effective Range:The effective range is approximately 50 meter, depends on actual condition, it may vary.
  • If the effective range is significantly shorter, please change battery.
  • W-2 wireless transmitter has 4 buttons, each function as follow:

Antari Z-1500 III Stage Fog Machine - W-2 Wireless Transmitter &
Receiver

12.2 W-2 Wireless Receiver Installation

If you purchased the WTR-20 Wireless Remote afterwards, please follow the instructions below to install the receiver. If you encounter any problem, please contact your local Antari dealer for assistant.

Antari Z-1500 III Stage Fog Machine - W-2 Wireless Receiver
Installation

  1. Please see graph 1, remove the cover from the pointed place;
  2. You will see a white cable like graph 2, pull it out and connect to the W-2 wireless receiver;
  3. Screw it back to the machine like graph 3 and follow the instruction on 12.3 for pairing.

12.3 Pair & Unpair

Each receiver can pair up to 5 transmitters, please follow the steps below to pair or unpair the module;

Step 1. Press and hold the [TIMER] knob for 3 seconds to enter menu;
Step 2. Rotate the [TIMER] knob to [Wireless Remote];
Step 3A. Press the [TIMER] knob to show , please press it again to show , then please press [Button A] of your W-2 Wireless Transmitter and wait display shows < Set Ok> to complete the pair procedure.
Step 3B. Press the TIMER knob to show , please press it again to show and then shows < Set Ok> to complete the unpair procedure.

Antari Z-1500 III Stage Fog Machine - Pair & Unpair

Z-3 Cable Remote (Optional)

Z-3 Cable Remote is an optional accessory for Z-1500III / Z-3000III Fog Machines, please see instruction below;

  1. Plug the cable remote to the connector on the back of the machine, red indicator light on (Power);
  2. Press the switch (Orange Indicator Light On); turn the knob to adjust the output to start fogging;
  3. Press the switch (Orange Indicator Light Off), or turn the knob to far left to stop fogging.

** If you encounter any problem, please contact your local Antari dealer for assistant

Service and Maintenance

Antari Z-1500 III Stage Fog Machine - Service and
Maintenance

  • Always keep the machine clean and dry.
  • Can use air compressor, vacuum or a soft brush to remove the dust on the machine.
  • Can use a slightly damp cloth to clean the casing.
  • Before store the machine, please make sure the machine is completely cool down to avoid moisture inside causing malfunction.
  • It is recommended to run the machine at least once a month in order to maintain the machine’s best performance and output condition.
  • Excessive dust and build up liquid residue will reduce the performance and cause overheat.

14.1 Breaker Reset (2 in 1 Power Switch)

The 2 in 1 power switch combines power and breaker function.
Please follow below steps to reset the breaker;
Step 1: Please switch to the OFF position;
Step 2: Wait 60 seconds;
Step 3: Flip switch to back.

**If the breaker (switch) still jumps off after reset, please contact your local Antari dealer for assistance.

Breaker Specification
100-120V = 15A 250V
220-240V = 9A 250V

Technical Specifications

Antari Z-1500 III Stage Fog Machine - Technical
Specifications

Warranty Disclaimer

We guarantee the merchandise manufactured by us to be free from defect in material and workmanship for a period of one year. Our obligation and liability under this warranty shall be restricted to repair or replacement at our factory or local authorized dealer. We assume no liability of the products that are improperly used or used for any purpose other than that for which they are specially designed. This warranty shall not apply to any merchandise which has been repaired, altered or assembled outside our factory in any way so as in our judgment to affect its performance, nor which has been subjected to misuse, negligence, or accident nor to any merchandise operated contrary to our printed instructions. We will not allow or be liable of any loss or any damages of any kind in connection with the use, sale, or repair of any merchandise purchased from us.

Machine Dimension

Antari Z-1500 III Stage Fog Machine - Machine
Dimension

Appendix I – Grounding Instruction

This appliance must be grounded. In the event of malfunction or breakdown, grounding provides a path  of least resistance for electric current to reduce the risk of electric shock. This appliance is equipped with a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.

DANGER – Improper connection of the equipment-grounding conductor can result in a risk of electric shock. The conductor with insulation having an outer surface that is green with or without yellow stripes is the equipment- grounding conductor. If repair or replacement of the cord or plug is necessary, do not connect the equipment-grounding conductor to a live terminal. Check with a qualified electrician or serviceman if the grounding instructions are not completely understood, or if in doubt as to whether the appliance is properly grounded. Do not modify the plug provided with the appliance – if it will not fit the outlet, have a proper outlet installed by a qualified electrician.

This appliance is for use on a nominal 120V circuit, and has a grounding plug that looks like the plug illustrated in sketch A in Figure. A temporary adaptor, which looks like the adaptor illustrated in sketches B and C, may be used to connect this plug to a 2-pole receptacle as shown in sketch B if a properly grounded outlet is not available. The temporary adaptor should be used only until a properly grounded outlet can be installed by a qualified electrician. The green colored rigid ear, lug, and the like, extending from the adaptor must be connected to a permanent ground such as a properly grounded outlet box cover. Whenever the adaptor is used, it must be held in place by the metal screw.

Antari Z-1500 III Stage Fog Machine - Appendix I – Grounding
Instruction

Antari Z-1500 logo

C08Z01302-CON

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals