This guide is intended for professional technicians who need to install and operate EyeW485. It is intended to provide readers with detailed information and instructions on installation and operation of EyeW485.

NOTICE

  • The content of the manual will be updated or revised from time to time as per the product development, which can be downloaded from http:/lsupport.sungrowpow­er.com/ or through scanning the QR code on the back cover of this guide.
  • All operations must be performed by professional technicians who have received special training, read the manual thoroughly, master the safety instruction related to operation, and be familiar with local standards and safety specifications of the electrical system.

Application Scenarios

SUNGROW-EyeW485-Communication-Module-FIG- \(1\)

NOTE

  • The EyeW485 slave node is installed on the communication interface of the inverter, and the master node is embedded in the device.The data between the device and the inverter can be transmitted once the connection between the master and slave nodes is established.
  • A master node and the slave nodes connected to it form an array.

NOTICE

  • EyeW485 only applies to inverters produced by SUNGROW. Scan the QR code on the back cover or the body to know the main model information.

Nameplate

SUNGROW-EyeW485-Communication-Module-FIG- \(2\)

SUNGROW-EyeW485-Communication-Module-FIG- \(3\)

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

To maintain compliance with FCC’s RF Exposure guidelines, This equipment should be installed and operated with minimum distance between 20cm the radiator your body: Use only the supplied antenna.

Installation Environment

SUNGROW-EyeW485-Communication-Module-FIG- \(4\)

Installation

SUNGROW-EyeW485-Communication-Module-FIG- \(5\)

Note: If a protective cover is installed at the inverter bottom, it may cause wireless communication signals to attenuate, thus shortening the communication distance of the communication module.

Indicator and Multi-function Button

SUNGROW-EyeW485-Communication-Module-FIG- \(6\)

Indicator Status Description

SUNGROW-EyeW485-Communication-Module-FIG- \(7\)

*Default array number is array1.
When RUN indicator and COM indicator blink slowly at the same time, the Bluetooth connection is established. Access to EyeW485 via iSolar Cloud App to check data and set parameters. Please scan the QR code below to view the iSolar Cloud App user manual for specific operations.
iSolar Cloud App User Manual
QR code

Multi-function Button

SUNGROW-EyeW485-Communication-Module-FIG- \(9\)

Add Device

SUNGROW-EyeW485-Communication-Module-FIG- \(10\)

Slave Node Parameter Setting

  • Step 1: Open iSolarCloud App, click Local Access at the bottom of the login interface, and scan the QR code on the connected inverter to go to the setting interface.
  • Step 2: Click More–+ Settings–+ Communication Parameters—+ EyeW485 to set the country/region and array. Unplug and plug the slave node to finish the parameter setting of the slave node.

Master Node Parameter Setting

Premises:

  • The array number of slave nodes have been set.

  • Successfully logged in to the web of COM100D/E.
    Login steps are briefly described by using the WLAN login as an example.

    • step1: Tum on the wireless network setting of the PC, and search for the  wireless network name of the Logger1000, for example,  sG-A 1234567890″.
      The fom1at of the wireless network name is SG-X. “X” representsThe wireless network can be connected without a password.

    • step2: Enter the IP address 11.11.11.1 of the COM100 in the PC address bar. Click the button “Login” in the upper right corner, enter the default password “pw1111″, and click Login”, to enter the main Web interface.

For more information, please refer to the relevant technical  documentation in Chapter 8, which can be obtained by scanning the QR code or visiting the web page.

  • step1 : Click “Device Maintenance”-> “Device List”-> “Auto Search” to enter the corresponding interface.
  • step2: Click the drop-down list of the EyeW485, select the array number , and click “Search”.
  • step3: Tick the inverter to be added when the search is completed and click “Save.

NOTICE

  • To transmit information, the array numbers and frequency points of the master and slave nodes must be consistent.