AtriCure IFU-0049.A AtriClip Left Atrial Appendage (LAA) Exclusion System User Manual
- June 12, 2024
- AtriCure
Table of Contents
Patient Leaflet
IFU-0049.A
Instructions for completion:
Physician/healthcare provider to fill out required information and to apply device label, from the Tyvek on the sterile barrier, to the patient card in the example location identified below, prior to giving this leaflet and the implant card to the patient/care giver.
Patient Information Leaflet
AtriClip Left Atrial Appendage (LAA) Exclusion System
Product Name/Description| Pre-loaded Clip| Product Code|
Picture
---|---|---|---
AtriClip Application Devices
AtriClip FlexV| V-clip| ACHV35 ACHV40 ACHV45 ACHV50|
AtriClip Flex| Gillinov- Cosgrove clip| ACH235 ACH240 ACH245 ACH250|
Patient Leaflet
AtriClip PRO Devices
AtriClip PRO| Gillinov- Cosgrove clip| PRO135 PRO140 PRO145 PRO150|
AtriClip PRO2| Gillinov- Cosgrove clip| PRO235 PRO240 PRO245 PRO250|
AtriClip PRO●V| V-clip| PROV35 PROV40 PROV45 PROV50|
Product Description:
The AtriClip Left Atrial Appendage (LAA) Exclusion Systems are indicated for
the occlusion of the heart’s LAA.
The intended population of patients are those patients who are eligible for
LAA exclusion. The Gillinov-Cosgrove clip devices should not be used if you
have a known allergy to nickel.
The AtriClip LAA Exclusion Systems are composed of a single-use, self-closing
implantable Clip preloaded onto a sterile, single-use applier. They are
designed to completely exclude blood flow between the LAA and the left atrium
during cardiac surgery. The Clip is an implant that permanently excludes the
LAA.
There are two different AtriClip designs of the implantable component (the
AtriClip). The traditional, Gillinov-Cosgrove clip and the V-clip (see images
below). Following the procedure, refer to your Patient ID Card to see which
AtriClip model was selected for your surgery.
Patient Leaflet
The traditional, Gillinov-Cosgrove LAA Exclusion Systems include the ACH2,
PRO1, and PRO2; only the appliers are different. The V-Clip LAA Exclusion
Systems include the ACHV and PROV with identical clip components, only
differing in the clip appliers.
The traditional, Gillinov-Cosgrove AtriClip consists of two Nitinol (nickel
titanium) springs and two titanium tubes which are covered with a knit braided
polyester fabric, composed entirely of polyethylene terephthalate (PET).
The device contains no microbial, animal or medicinal components.
The AtriClip V-Clip consists of a single titanium core with a set of opposing
springs, covered with a knit braided polyester fabric, composed entirely of
PET. The device contains no microbial, animal or medicinal components.
Reasons for needing the device:
Your healthcare provider team has recommended that your LAA be closed with an
AtriClip as part of your cardiac surgery procedure. The AtriClip will remain
on the LAA of your heart to ensure itremains closed.
Side effects:
There are no side effects associated with the implant of the AtriClip;
however, your surgeon will inform you of potential adverse effects from your
heart procedure.
Contact your doctor if you experience unexpected side effects after your
procedure or have questions about your implant.
Warnings/Precautions:
MRI- Magnetic resonance imaging (MRI) is a medical imaging technique that uses
magnetic fields to create images of the body. The AtriClip device is MR
conditional, so you can be scanned safely in an MR system immediately after
placement. You should still talk to your doctor if you need imaging studies to
discuss the specific conditions of your imaging study. Showing your patient
information card (PIC) may be helpful as the PIC specifies your implanted
device.
The AtriClip device will become fully encapsulated in the surrounding tissues
while remaining implanted for the patient lifetime.
Precautions:
You should follow and comply with all physician recommendations, precautions,
and post-surgical medical appointments.
About Your Procedure
Pre-operative Screening:
During the preoperative screening phase (before the surgery is performed) the
following evaluations may be reviewed or performed:
- A physical exam
- Blood tests to rule out infection and to check for a normal red blood cell count and platelet count
The following tests may also be completed during this visit:
- A urine pregnancy test
- A Transthoracic (across the chest) Echocardiogram (TTE) will be performed at this visit if one is not already documented in your recent medical history. This is used to produce images and sounds that can be used by the physician to detect damage and disease, and the size and function of your heart.
Intra-operative (day of surgery):
The following will occur during your surgical procedure:
- A Transesophageal Echocardiogram (TEE) probe will be used to confirm that there are no clots in your atria (the upper chambers of your heart), and to assess the function and size of your heart. This procedure requires a probe to be inserted down your throat into the esophagus (the organ that connects the throat to the stomach). You will be under anesthesia while this study is performed. This procedure is a standard part of the surgery.
- The heart surgery required to correct your heart problem (if applicable). During the surgery, your surgeon will use the AtriClip device to close off the LAA of your heart.
- The TEE will be used to confirm that your LAA is completely closed off by the AtriClip. You will still be under anesthesia while this happens.
Post-Operative (prior to discharge):
The following procedures will be performed:
- A physical exam, including a review of any complications you experienced during your hospital stay
- A review of all medications you have taken while in the hospital prior to discharge
- Blood tests to assure a stable blood volume, that you do not have an infection, and that your liver and kidneys are functioning properly.
Any serious incidents occurring in relation to the device should be reported to the Manufacturer (AtriCure, Inc. 7555 Innovation Way, Mason, OH 45040 USA 1-866-349-2342) and the Therapeutic Goods Administration at https://www.tga.gov.au/
7555 Innovation Way
Mason, OH 45040 USA
1-866-349-2342