Dial PEC-A-7500-1M Portable Evaporative Cooler User Manual
- June 12, 2024
- Dial
Table of Contents
- Dial PEC-A-7500-1M Portable Evaporative Cooler
- Product Information
- Product Usage Instructions
- SAFETY INSTRUCTIONS
- APPLICATIONS
- FEATURES
- SPECIFICATIONS
- HOW EVAPORATIVE AIR COOLERS WORK
- EXTERIOR PARTS OF THE EVAPORATIVE COOLER
- UNPACKING AND INSTALLING CASTERS
- CONTROL PANEL OPERATIONS
- OPERATING THE EVAPORATIVE COOLER
- MAINTENANCE
- TROUBLESHOOTING
- CONTACT
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Dial PEC-A-7500-1M Portable Evaporative Cooler
Product Information
Thank you for choosing Dial. Please read this User Manual before using this Portable Evaporative Cooler. Retain the manual for future reference.
Product Usage Instructions
Ensure to follow these safety instructions:
- If you are experiencing difficulty with your portable evaporative cooler, do not return it to the place of purchase. Contact Dial Manufacturing for help or disposition.
- Read and understand the safety instructions provided in the user manual.
- Follow energy saving and unit safety protection tips mentioned in the manual.
SAFETY INSTRUCTIONS
- Read the instructions thoroughly before operating the unit.
- Always place the unit on a dry, flat and stable surface and apply brakes on the caster wheels.
- Do not move or tilt the unit while the water tank is full.
- The outdoor use of this portable evaporative cooler must be supervised.
- The unit is not designed to be exposed to wet conditions such as rain.
- This unit can only be connected to a 110-115V, 60Hz and Single-Phase electrical outlet.
- This evaporative cooler has been tested and is safe to use. However, as with the use of any electrical appliance, take care when using the unit.
- Test and reset the GFCI plug before connecting it to an electrical outlet.
- Do not connect the unit to an extension cord for power supply.
- Never operate this appliance if the cord or plug is damaged.
- A damaged power cord should be replaced by the manufacturer or a qualified electrician.
- This evaporative cooler is not to be operated by persons (including children) without experience and knowledge of using the cooler.
- Do not leave children near the evaporative cooler unsupervised.
- Do not touch any moving or rotating parts inside the unit.
- Never insert fingers or any other objects though the louvre or guard.
- The operation of the evaporative cooler should not be left unattended for an extended period.
- Disconnect the evaporative cooler from the electrical outlet before cleaning, maintaining or servicing the unit.
- Do not clean the unit by spraying it or immersing it in water. Use a moist cloth to wipe and clean the exterior of the unit. Use caution when wiping the Control Panel; make sure no water enters the control panel.
- Any service other than regular cleaning or filter replacement should be performed by an authorised service personnel. Failure to comply may void the warranty of the unit.
- Do not use the evaporative cooler for any purpose other than its intended use.
- Never use the plug as a switch to turn on or off the unit. Use the provided ON/OFF switch located on the control panel.
- Use this evaporative cooler in a well ventilated area and not in an enclosed area.
- Do not use this unit in environments with flammable and explosive gases.
- Avoid placing the unit in direct sunlight for an extended period.
ENERGY SAVING AND UNIT SAFETY PROTECTION TIPS
- Operate the unit at a location that has cross ventilation. Evaporative air coolers use evaporation to achieve a natural cooling effect which requires cross ventilation for maximum efficiency.
- To ensure the evaporative cooler operates efficiently, do not block or restrict the air-intake through the inlet grills on the side and back, or airflow out of the louvre in front.
- For maximum performance, do not place the back of the unit within 20 inches of a wall or other objects.
- When the unit is in operation, the water in the water tank must not exceed the MAX level and must not fall below MIN level.
- Keep the Dust Screen clean to allow better air-intake and efficient operation of the unit.
- This unit will lose efficiency if the relative humidity in the room exceeds 60%.
- The ambient operating temperature range is from 41°F to 125°F.
- This evaporative cooler may operate as a humidifier in low temperature environment using warm water (not hot water) instead of cool water.
APPLICATIONS
- Alternative and economical spot cooling solution for areas and spaces which cannot be sealed or traditionally air conditioned.
- Dial® Portable Evaporative Cooler can be used in garage, workshop, barn / stable, on patio and commercial open spaces such as sidewalk cafes and outdoor seating & dining.
FEATURES
- Powerful air-flow perfect for spot cooling.
- Directional swing allows wider area coverage.
- 3 fan speeds and oscillation setting for wider and improve air flow: low, medium and high-speed allow adjustment between maximum cooling and quiet operation.
- Removable and washable dust screen for improved cooling and clean airflow.
- Handle and castors for great mobility.
- “Auto” water re-fill with garden hose connection and float valve shut-off.
SPECIFICATIONS
- Air Flow: Up to 7500 CFM (ft3/min)
- Water Tank: 26.4 Gallons
- Motor / Fan Speed: 1.25 HP 3 / Fan Speed: Low / Medium / High
- Control: Rotary Dial
- Cooling Media: 3-Sided High Efficiency Rigid Honeycomb Media Pads Swing Function Auto Vertical Left to Right / Manual Horizontal Top/Down
- Dimension: 31.89×22.05×58 Inches
- Weight: 97 lbs
- Certification: ETL Certified
HOW EVAPORATIVE AIR COOLERS WORK
The evaporative cooler cools the air by means of evaporation. When water evaporates, liquid water is converted into vapor using the thermal energy in the air resulting in a lower air temperature and spot cooling effect. Evaporative cooling therefore causes a drop in the temperature of air proportional to the sensible heat drop and an increase in humidity proportional to the latent heat gain.
- The recommended relative humidity for optimum operation is 60% or lower. A drier climate makes for more noticeable cooling.
- The evaporative air cooler should not be used in enclosed or sealed spaces. It must be kept level and there must always be water in the water tank. In a room setting, doors and windows should be open to allow cross air flow.
- When the product is used for the first time the Honeycomb cooling media may have an odor. This should dissipate within a week of use.
EXTERIOR PARTS OF THE EVAPORATIVE COOLER
UNPACKING AND INSTALLING CASTERS
- Keep the evaporative cooler in an upright position and remove the packaging.
- Make sure all the parts are present: Castors (4pcs) & Screws (16pcs).
- Lay the evaporative cooler on its side gently. Locate screw holes for the casters under the Reservoir. Use the screws provided to fasten the casters to the underside of the Reservoir. Set the cooler right-side up when the casters are installed.
CONTROL PANEL OPERATIONS
| Use this dial to select fan speed. To turn “on” the fan, turn “FAN” dial
from “OFF” to “L”, “M” or “H” (Low, Medium or High).
---|---
****| To activate evaporative cooling turn “PUMP” dial from “OFF” to
“ON”. Ensure that the water level is sufficient for the operation. If this
function is not turned on the unit operates as a fan / air cleaner.
| **** To activate the swing mode turn “SWING” dial from “OFF” to “ON”.
The airflow will swing from left to right. The up-down airflow can be
controlled manually by adjusting the horizontal louvre.
OPERATING THE EVAPORATIVE COOLER
FILL THE RESERVOIR
Fill the reservoir with clean water through the Water Filler Door manually. To
open the Water Filler Door, depress the door at the center on the top edge of
the door. Do not fill the water beyond the maximum water level. Close Water
Filler Door when the reservoir is filled. Alternatively, connect a garden hose
to the hose valve (use the hose adaptor provided) which also provide
continuous water fill. The reservoir must be filled with a minimum volume of
water before using the cooling function. The water has to be at least half
full on the Water Level Gauge. PLUG IN THE GFCI PLUG INTO AN GFCI ELECTRICAL
OUTLET IF AVAILABLE
Note: The GFCI Plug can be plugged into an ordinary 110-115V electrical
outlet.
Press the “Re-set” button on the GFCI plug first and connect the GFCI power
plug to a GFCI electrical outlet. Re-set GFCI outlet if necessary. TO TURN ON
THE EVAPORATIVE COOLER, TURN THE “FAN” ROTARY DIAL FROM “OFF” TO “L, M OR H”.
USE THIS DIAL TO SELECT FAN SPEED. TO ACTIVATE EVAPORATIVE COOLING, TURN
“PUMP” DIAL FROM “OFF” TO “ON”. Check the water level to ensure that the water
level is sufficient for the operation. TURN THE “SWING” DIAL FROM “OFF TO “ON”
THE “OSC” BUTTON FOR THE AIRFLOW TO OSCILLATE LEFT AND RIGHT.
Note: It is completely normal if the cooler has a slight odor or the
water tank has slight discolouration when it is used for the first time.
MAINTENANCE
CLEANING
CAUTION: Turn off the evaporative cooler and disconnect the plug from the
electrical outlet before cleaning, servicing or performing any maintenance on
the unit.
CLEANING THE EXTERIOR SURFACE OF THE EVAPORATIVE COOLER
- Clean the plastic housing with a duster or a soft moist cloth.
- Do not use chemical solvents (such as benzene, alcohol or gasoline) as they may cause irreversible damage.
- Use care when cleaning around the control panel and the control panel itself; make sure no water enters the control panel. Control Panel warranty does not cover damage caused by water.
CLEANING THE RESERVOIR
- Unplug the appliance then remove the screws securing the rear filter frame.
- Lift the filter frames to remove from the unit.
- Drain the Reservoir by removing the Drain Plug on the underside of the Reservoir.
- With a cloth (dipped in mild detergent solution), wipe the Reservoir and rinse it with water.
- Cleaning the Reservoir at least once a week will help reduce any mineral deposits and keep the filters clean.
- Do not run the unit in cooling mode with stale water in the Reservoir.
- Empty the reservoir and refill it with fresh water if water has been left in the Reservoir for an extended period.
MAINTAINING AND CHANGING THE RIGID MEDIA PADS
The frequency of cleaning the Rigid Media Pads depends on local air and
water conditions. In areas where the mineral content of the water is high
(hard water), mineral deposits may build up on the media pads and restrict air
flow. If mineral deposits remain on the media pads, they should be removed and
washed under fresh water or replaced. We recommend cleaning the media pads at
least every two months, depending on water conditions. For best results, allow
the media pads to dry after each use by turning off the cooling function for
15 minutes (without water in the Reservoir) before turning the unit off. Go to
www.dialmfg.com/pec/technical-data. for detailed instructions on removing and replacing Rigid Media Pads.
END OF SEASON MAINTENANCE
- Empty the reservoir and wipe it with warm soapy water.
- Dry the reservoir and clean the Honeycomb pads.
- Cover the unit and keep it in a dry place.
TROUBLESHOOTING
Do not repair or disassemble the unit by yourself, unauthorized repair attempts will void the warranty and may cause injury.
Problem | Cause/Corrective Action (Control Panel) |
---|---|
A. Cooler does not work at all. | 1. GFCI Plug on the unit power cord is not |
plugged into the electrical outlet properly.
2. Re-set the GFCI Plug
3. The GFCI outlet may have been tripped and need to be re-set. Or use a non GFCI outlet.
4. Turn “FAN” dial to “L, M or H” turn “On” evaporative cooler.
B. No Cool Air| 1. Pump is not activated. Turn “PUMP” dial to “ON” switch on the pump.
2. Water level is low. Fill reservoir with water (at least half full) and activate pump.
3. Pump and/or Pump Hose are/is clogged. Clear debris.
4. Pump may be defective and need to be replaced.
C1. Fan does not operate.
C2. Fan runs slow
| a) GFCI Plug on the unit power cord is not plugged into the electrical outlet properly.
b) Re-set the GFCI Plug.
c) The GFCI outlet may have been tripped and need to be re-set. Or use a non GFCI outlet.
d) Turn “FAN” dial to “L, M or H” turn “On” evaporative cooler.
e) Check for faulty motor capacitor. Motor capacitor may need to be replaced (for select models).
D. Vertical louvre does not operate| Louvre does not move. Turn “SWING” dial
to “ON”. Check oscillation motor for connection and defect.
E. Leakage| 1. Check Drain Plug or Cap. Make sure Drain Plug is plugged
fully and Cap is tightened completely.
2. Inspect Reservoir for cracks or damage.
3. Check for Media Pad scale build-up. Scaling can cause water flow disruption and spill water out of the unit.
4. Check for leaks from Water Spreader/Distributor Rail and hose connections.
F. Float Valve| 1. Adjust the valve if the water level is too low or high.
2. Check for a crack on the float valve causing valve failure and water leakage. Replace cracked float valve.
G. Odor emission| 1. New unit. When the unit is used for the first time, the Rigid Media Pad will have an odor, which will dissipate within a week of use.
2. Media Pad may have developed mold or bacterial growth. Replace Media Pad.
If the above solutions do not resolve the problem, please contact Dial Customer Service and Technical Support.
WARRANTY POLICY
Refer to Warranty Form.
DAMAGED SHIPMENT
Dial is not responsible for any damages caused by shipment. Dial is not
responsible for any shortages incurred during shipment. If there are any
damages or shortages, please notify the carrier and file a claim. Do not
dispose of the product, as the carrier may request evidence of the damage.
PRODUCT RETURN
Please make note of the dealer return policy at the location where purchased,
as the return policy of Dial product is determined on the dealer level. The
ability to return product is at the sole discretion of the dealer. For the
repair of damaged product, or for troubleshooting, the customer may contact
Dial for assistance.
PEC-A-7500-1M PORTABLE EVAPORATIVE COOLER REPLACEMENT PARTS
These replacement parts are available at participating dealers of Dial®
Portable Evaporative Coolers or call 1-800-350-DIAL for assistance.
PART MODEL NUMBER | PART DESCRIPTION | PART NUMBER |
---|---|---|
PEC-RP-001-7500 | Water Pump | 82021 |
PEC-RP-002-8888A | Float Valve Set | 82001 |
PEC-RP-004-8888C | Control Dial | 82002 |
PEC-RP-006-7500 | Fan Blade | 82007 |
PEC-RP-010-7500 | Rigid Media Pad (Set) | 82011 |
PEC-RP-011-7500 | Dust Cover/Screen (Set) | 82015 |
PEC-RP-012-8888C | Drain Plug | 82017 |
PEC-RP-013-8888A | Hose Adaptor | 82018 |
PEC-RP-015-7500 | Wheel (1 per) | 82028 |
Thank you for choosing Dial
Please read this User Manual before using this Portable Evaporative Cooler
Retain the manual for future reference.
Attention: If you are experiencing difficulty with your portable
evaporative cooler, do not return it to the place of purchase. Contact Dial
Manufacturing for help or disposition.
CONTACT
- Dial Manufacturing, Inc.
- 430 North 47th Avenue, Phoenix, AZ 85043
- 1-800-350-DIAL
- customerservice@dialmfg.com.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>