FS S5800-48MBQ Managed L3 Multi-Gigabit Switch User Guide

October 31, 2023
FS

FS S5800-48MBQ Managed L3 Multi-Gigabit Switch

FS-S5800-48MBQ-Managed -3-Multi-Gigabit-Switch-PRODUCT

Product Information

Model S5800-48MBQ
Type Managed L3 Multi-Gigabit Switch

Product Usage Instructions

Hardware Overview
The S5800-48MBQ switch comes with the following front panel ports:

  • CON – RJ45 console port for serial management
  • ETH – Ethernet management port
  • RJ45 – 100/1000/2500BASE-T ports for Ethernet connection
  • QSFP+ – ports for 40G transceivers
  • SFP28 – ports for 10G/25G transceivers

Front Panel LEDs:

LEDs Status Description
ID Blue ID indication function enable
ID Off ID indication function disable
SYS Green System is running normally
SYS Amber System occurs alarm or error
SYS Off No power or no system runs or runs abnormally
ETH Green Blinking Port is linked
ETH Green Port is receiving or transmitting packets
ETH Off Port is not linked

Back Panel:

  • Gounding Point
  • 4 Hot-swappable Fans
  • 2 Hot-swappable Power Supplies

Installation Requirements:
Before you begin the installation, make sure that you have the following:

  • Phillips screwdriver
  • M6 Screws
  • Standard-sized, 19 wide rack with a minimum of 1U height available
  • Category 5e or higher RJ-45 Ethernet cables, fiber optical cables, and console cable for connecting the network devices

Mounting the switch:

Desk Mounting:

  1. Attach four rubber pads to the bottom of the switch.
  2. Place the chassis on a desk.

Rack Mounting :

Refer to the user manual for detailed instructions on rack mounting.

Introduction

Thank you for choosing S5800-48MBQ switch. This guide is designed to familiarize you with the layout of the switch and describes how to deploy the switch in your network.FS-S5800-48MBQ-Managed -3-Multi-Gigabit-Switch-FIG-
\(1\)

Accessories

FS-S5800-48MBQ-Managed -3-Multi-Gigabit-Switch-FIG-
\(2\)

Hardware Overview

Front Panel PortsFS-S5800-48MBQ-Managed -3-Multi-Gigabit-Switch-FIG-
\(3\)

Front Panel LEDsFS-S5800-48MBQ-Managed -3-Multi-Gigabit-Switch-FIG-
\(4\)

Back PanelFS-S5800-48MBQ-Managed -3-Multi-Gigabit-Switch-FIG-
\(5\)

Installation Requirements

Before you begin the installation, make sure that you have the following:

  • Phillips screwdriver.
  • M6 Screws.
  • Standard-sized, 19″ wide rack with a minimum of 1U height available.
  • Category 5e or higher RJ-45 Ethernet cables, fiber optical cables and console cable for connecting the network devices.

Site Environment:

  • Do not operate it in an area that exceeds an ambient temperature of 45°C.
  • The installation site must be well ventilated. Ensure that there is adequate air flow around the switch.
  • Be sure that the switch is level and stable to avoid any hazardous conditions.
  • Do not install the equipment in a dusty environment.
  • The installation site must be free from leaking or dripping water, heavy dew, and humidity. Ensure rack and working platforms are well earthed.

Mounting the switch

Desk MountingFS-S5800-48MBQ-Managed -3-Multi-Gigabit-Switch-FIG-
\(6\)

  1. Attach four rubber pads to the bottom.
  2. Place the chassis on a desk.

Rack MountingFS-S5800-48MBQ-Managed -3-Multi-Gigabit-Switch-FIG-
\(7\)

  1. Secure the mounting brackets to the two sides of the switch with six M4 screws.FS-S5800-48MBQ-Managed -3-Multi-Gigabit-Switch-FIG- \(8\)
  2. Attach the switch to the rack using four M6 screws and cage nuts.

Grounding the SwitchFS-S5800-48MBQ-Managed -3-Multi-Gigabit-Switch-FIG-
\(9\)

  1. Connect one end of the grounding cable to a proper earth ground, such as the rack in which the switch is mounted.
  2. Secure the grounding lug to the grounding point on the switch back panel with the washer and screws.

CAUTION : The earth connection must not be removed unless all supply connections have been disconnected.

Connecting the PowerFS-S5800-48MBQ-Managed -3-Multi-Gigabit-Switch-FIG-
\(10\)

  1. Plug the AC power cord into the power port on the back of the switch.
  2. Connect the other end of the power cord to an AC power source.
    WARNING : Do not install power cable while the power is on.

Connecting the RJ45 PortsFS-S5800-48MBQ-Managed -3-Multi-Gigabit-Switch-
FIG- \(11\)

  1. Connect an Ethernet cable to the RJ45 port of a computer, printer, network storage, or other network devices.
  2. Connect the other end of the Ethernet cable to the RJ45 port of the switch.

Connecting the QSFP+ PortsFS-S5800-48MBQ-Managed -3-Multi-Gigabit-Switch-
FIG- \(12\)

  1. Plug the compatible QSFP+ transceiver into the QSFP+ port.
  2. Connect a fiber optic cable to the fiber transceiver, then connect the other end of the cable to another fiber device.
  3. Or directly connect DAC/AOC cable to the QSFP+ port.

CAUTION : Laser beams will cause eye damage. Do not look into bores of optical modules or optical fibers without eye protection.

Connecting the SFP28 PortsFS-S5800-48MBQ-Managed -3-Multi-Gigabit-Switch-
FIG- \(13\)

  1. Plug the compatible SFP28 transceiver into the SFP28 port.
  2. Connect a fiber optic cable to the fiber transceiver, then connect the other end of the cable to another fiber device.
  3. Or directly connect DAC/AOC cable to the QSFP28 port.

CAUTION : Laser beams will cause eye damage. Do not look into bores of optical modules or optical fibers without eye protection.

Connecting the Management Ports

Connecting the Console Port

FS-S5800-48MBQ-Managed -3-Multi-Gigabit-Switch-FIG-
\(14\)

  1. Insert the RJ45 connector of the console cable into the RJ45 console port on the front of the switch.
  2. Connect the other end of the console cable to the RS-232 serial port on the computer.

Connecting the ETH PortFS-S5800-48MBQ-Managed -3-Multi-Gigabit-Switch-
FIG- \(15\)

  1. Connect one end of a standard RJ45 Ethernet cable to a computer.
  2. Connect the other end of the cable to the ETH port on the front of the switch.

Configuring the Switch

Configuring the Switch Using the Web-based Interface

  • Step1 : Connect the computer to the Management port of the switch using the network cable.
  • Step 2 : Set the IP address of the computer to 192.168.1.x. (“x” is any number from 2 to 254.). Set the subnet mask of the computer to 255.255.255.0.FS-S5800-48MBQ-Managed -3-Multi-Gigabit-Switch-FIG- \(16\)
  • Step 3 : Open a browser, type http://192.168.1.1, and enter the default username and password, admin/admin.
  • Step 4 : Click sign in to display the web-based configuration page.

Configuring the Switch Using the Console Port

  • Step 1: Connect a computer to the switch’s console port using the supplied console cable.
  • Step 2: Start the terminal simulation software such as HyperTerminal on the computer.
  • Step 3: Set the parameters of the HyperTerminal: 115200 bits per second, 8 data bits, no parity, 1 stop bit and no flow control.FS-S5800-48MBQ-Managed -3-Multi-Gigabit-Switch-FIG- \(17\)
  • Step 4: Enter the default username and password, admin/admin.

Troubleshooting

Loading Failure Troubleshooting
After loading fails, the system will keep running in the original version. At this time, users should re-check if physical port connections are good firstly. If some ports are not connected, then
re-connect them to ensure that physical connections are correct, and begin re- loading. If physical connections are correct, then check the loading process information displayed on the super terminal to verify if there are input errors. If there are input errors, correct them and re-load.

User Password Lost Troubleshooting
If system password is lost or forgotten, the following method can be used to reset the password:

  • Connect the console port of the switch to the computer through the console cable.
  • Press ctrl + b to enter the Uboot mode.
  • Start the system with an empty configuration file with no password.

Bootrom#boot_flash_nopass
Bootrom#Do you want to revert to the default config file?[Y|N|E]:
NOTE : Forgetting your username and password and restoring them through console port may cause configuration loss and business interruption. Please remember your username and password.

Configuration System Troubleshooting

  1. Make sure the power supply is normal and the console cable is properly connected.
  2. Check if the console cable is the right type.
  3. Check if the control cable driver is properly installed on the computer.
  4. Ensure the parameters of the HyperTerminal are correct.

Support and Other Resources

Product Warranty

  • FS ensures our customers that any damage or faulty items due to our workmanship, we will offer a free return within 30 Days from the day you receive your goods. This excludes any custom made items or tailored solutions.
  • Warranty : S5800-48MBQ Switch enjoys 5 years limited warranty against defect in materials or workmanship. For more details about warranty, please check at https://www.fs.com/policies/warranty.html
  • Return : If you want to return item(s), information on how to return can be found at https://www.fs.com/policies/day_return_policy.html

Compliance Information

FCC

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

CAUTION:
Any changes or modifications not expressly approved by the grantee of this device could void the user’s authority to operate the equipment.
Responsible party (only for FCC matter) FS.COM Inc.
380 Centerpoint Blvd, New Castle, DE 19720, United States https://www.fs.com
FS.COM GmbH hereby declares that this device is in compliance with the Directive 2014/30/EU and 2014/35/EU. A copy of the EU Declaration of Conformity is available at www.fs.com/company/quality_control.html
FS.COM LIMITED
24F, Infore Center, No.19, Haitian 2nd Rd,Binhai Community, Yuehai Street,Nanshan District, Shenzhen City
FS.COM GmbH NOVA Gewerbepark Building 7, Am Gold 7, 85375 Neufahrn bei Munich, Germany
Copyright © 2021 FS.COM All Rights Reserved

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals