MARZ DESIGNS Large Selene Uplight Installation Guide

June 12, 2024
Marz Designs

MARZ-DESIGNS-LOGO

MARZ DESIGNS Large Selene Uplight

Product Information

  • Product: Selene Uplight, Large, 240V
  • Product Code: MARZ-SELENE-UP-L
  • Rated Voltage: 220-240VAC
  • Frequency: 50 Hz
  • Fitting: 1 lamp 4.5W LED
  • Lamp Type: G9
  • Danger: Lights must be installed by a qualified electrician. Electric shock risk.
  • Terminal block: Shall conform to IEC 60998-2-1 or IEC 609982-02 and must comply with the following specifications.
  • Manufacturer Website: www.marzdesigns.com

Product Usage Instructions

  1. Drill a 65mm hole in the wall using a holesaw to allow for cable termination. Use wall anchors (not provided) to fix the universal mounting plate to the wall. Make sure the universal mounting plate is installed level.
  2. Connect the electrical leads from the wall to the leads from the fixture. Ensure the wires are secure and no bare wires are exposed, using an enclosed junction box.
  3. Install the canopy on the wall over the universal mounting plate and secure it in place with the supplied screw head caps.
  4. Wind back the lock nut on the fixture ready to install the timber shade.
  5. Slide the timber shade over the fixture socket.
  6. Wind forward the lock nut to level and straighten the timber shade.
  7. Screw on the bevelled lock ring to secure the timber shade in place.
  8. Push the light globe into the fixture socket.
  9. Screw the glass cover onto the fixture socket.
    Caution: Align the threads properly for smooth rotation before twisting to avoid jamming. Do not over-tighten the globe.

Please carefully read instructions before use:

  • PRODUCT: Selene Uplight, Large, 240V
  • PRODUCT CODE: MARZ-SELENE-UP-L
  • RATED VOLTAGE: 220-240VAC
  • FREQUENCY: 50 HZ
  • FITTING: 1 lamp 4.5W LED
  • LAMP TYPE: G 9

SAFETY INSTRUCTION

DANGER: Lights must be installed by a qualified electrician. Electric shock risk.

  • Turn off electrical power before beginning installation and use caution when installing.
  • Please do not modify or adjust any fixture in a way that is not clearly stated or intended.
  • Always ensure the power is off and the luminaire has cooled down before performing any maintenance to the fitting.
  • To avoid injury or damage to the luminaire, ensure that power leads and screws are secure before connecting the power.
  • Select a suitable location away from liquids and hazards.
  • Ensure that the luminaire does not come in contact with corrosive chemicals/solvents or abrasive cleaners etc.
  • To avoid electric shock, do not touch this item if your hands are wet.
  • To clean, wipe with a soft damp cloth. Do not soak or immerse the luminaire in water or other liquids.
  • Do not use if any breakage or distortion is found on the wiring or socket, or if the products have been wet.
  • Marz Designs is not responsible for any damages caused by not following the provided instructions.

This luminaire is intended for mounting to a wall:

  • Carefully check the luminaire and wiring for damage before use. Do not use the fixture if it is damaged.
  • Ensure that local voltage and frequency match the marking.
  • For indoor use only.
  • Do not disassemble the structure of the fixture.
  • Do not leave children alone with the product.
  • If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by the manufacturer to avoid hazard.
  • Please use reliable suspending and fixing devices to avoid danger.
  • This is a Class I device and must be connected to a protective grounding.
  • The terminal block and connection box is not included.
  • Only qualified personnel may install this device. Please observe national installation regulations.

SPECIFICATION

The terminal block shall conform to IEC 60998-2-1 or IEC 60998- 2-02 and must comply with the following specifications:

  • With screw or screw-less terminal
  • Two terminal poles;
  • Rated voltage: 250V
  • Rated connecting capacity: 10 A; 3 x 0.75-1.5mm²
  • During installation, ensure that the basic insulation of the supply lead does not touch the wall cover. Use proper insulation so that the clearance and distance between the live parts and the wall cover is more than 6.5mm between the basic insulation of the supply lead and 3.6mm between the wall cover.
  • Keep the terminal block inside the wall cover or fixed to the wall.

INSTALLATION GUIDE

INSTRUCTIONSMARZ-DESIGNS-Large-Selene-Uplight-1

  1. Drill 65 mm hole in Wall (A) using a hole saw to allow for cable termination. Use Wall Anchors (not provided) to fix the Universal Mounting Plate (B) to Wall (A).
    NOTE: Ensure Universal Mounting Plate (B) is installed level.

  2. Connect electrical leads from the Wall to the leads from the Fixture. Ensure the wires are secure and no bare wires are exposed, using an enclosed junction box.

  3. Install the Canopy (C) on the Wall over the Universal Mounting Plate (B) and secure in place with screw head Caps (D ) supplied.MARZ-DESIGNS-Large-Selene-Uplight-2

  4. Wind back the Lock Nut (E) on the Fixture ready to install Timber shade (F).

  5. Slide the Timber Shade (F) over the Fixture Socket (G).

  6. Wind forward the Lock Nut (E) to level and straighten Timber Shade (F).

  7. Screw on Bevelled Lock-ring (H) to secure Timber Shade (F) in place.

  8. Push the Light Globe (I) into the Fixture Socket (G).

  9. Screw the Glass Cover (J) onto the Fixture Socket (G).
    CAUTION: Align threads properly for smooth rotation before twisting to avoid jamming. Do not over-tighten the globe.

www.marzdesigns.com

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals