Current Lighting 95046985 Cable Suspension Kit Installation Guide
- June 12, 2024
- Current Lighting
Table of Contents
Current Lighting 95046985 Cable Suspension Kit Installation Guide
BEFORE YOU BEGIN
WARNING/AVERTISSEMENT
RISK OF ELECTRIC SHOCK
- Turn power off before inspection, installation or removal.
- Properly ground electrical enclosure.
RISK OF FIRE
- Follow all NEC and local codes.
RISQUES DE DÉCHARGES ÉLECTRIQUES
- Coupez l’alimentation avant d’’inspecter, installer ou déplacer le luminaire.
- Assurez-vous de correctement mettre à la terre le boîtier d’alimentation électrique.
RISQUES D’ INCENDIE
- Respected toes les codes NEC et codes locus.
Kit Contains:
- Suspension cable -10’ (2x)
- Toggled cross-cable (2x)
- Cross-cable gripper (2x)
- M6 bolt (2x)
- 1/4-20 cable coupler (2x)
- Hourglass sleeve (2x)
-
Connect Gripper To Luminaire Mounting System
The Lower Mounting Kit is designed to connect either directly to a compatible luminaire or to a mounting bracket included with the luminaire and provide leveling through the adjustment of the cable position.
For luminaires/mounting brackets with dual mounting holes: Connect toggled cross cable as shown and adjust position to level. Ensure M6 bolt is tightened into gripper after levelling.
For mounting brackets with a single central hole: Remove cross cable from gripper and use M6 bolt to attach gripper directly to bracket. -
Connect Aircraft Cable To Ceiling Structure
The Lower Mounting Kit can connect to the ceiling structure in one of two ways:
Loop onto structure: Using hourglass sleeve loop aircraft cable over existing building structure and pull tight. Ensure structure is rated for luminaire load before mounting.
Couple to ¼-20 rod: Install aircraft cable through ¼-20 coupler and tighten coupler onto ¼-20 rod attached to building structure. For finished drywall or T-grid ceilings use KIT-MTG-UPR (93026986) to provide ¼-20 thread. Ensure ceiling structure is rated for luminaire load before mounting. -
Attach Aircraft Cable To Gripper And Adjust Height
Pass aircraft cable end through hole at top of cross gripper and pull through until desired level is reached.
Note: Height cannot be adjusted while gripper is under load. Once mounting brackets are properly levelled luminaires can be installed into brackets according to the specific instructions provided with the luminaire.