levelone FVT Series Copper to Fiber Stand Alone Media Converter User Manual

June 12, 2024
LevelOne

levelone FVT Series Copper to Fiber Stand-Alone Media Converter

levelone-FVT-Series-Copper-to-Fiber-Stand-Alone-Media-Converter-
PRODUCT

Product Information

Model No. Description
FVT-2001 10/100BASE-TX to 100BASE-FX MMF SC Converter, 2km
FVT-2002 10/100BASE-TX to 100BASE-FX MMF ST Converter, 2km
FVT-2201 10/100BASE-TX to 100BASE-FX SMF SC Converter, 20km
FVT-2202 10/100BASE-TX to 100BASE-FX SMF SC Converter, 20km
FVT-2401 10/100BASE-TX to 100BASE-FX SMF SC Converter, 40km
GVT-2000 10/100/1000BASE-T to 1000BASE-X SFP Converter
GVT-2001 10/100/1000BASE-T to 1000BASE-SX MMF SC Converter, 550m
GVT-2002 10/100/1000BASE-T to 1000Base-SX/LX SMF SC Converter, 20km
GVT-2003 10/100/1000BASE-T to 1000Base-SX/LX SMF ST Converter, 20km

Product Usage Instructions

  1. Connect the RJ-45 Port on the front panel of the converter to the Ethernet device using an Ethernet cable.
  2. Connect the Fiber/SFP Connector on the front panel of the converter to the fiber optic network using a fiber optic cable.
  3. Ensure that the LED indicators on the front panel are displaying the correct status for the connection.
  4. If required, configure the DIP switch on the rear panel to enable Link Lost Forwarding (LLF) and Flow-Control function for the UTP/Fiber port.
  5. Refer to the user manual for more detailed information on cabling, specifications, and optional SFP modules.

Introduction

LevelOne media converters are Fast Ethernet 10/100Base-TX to 100Base-FX and 10/100/1000Base-T to 1000Base-SX/LX converters to provide the flexibility required in network integration. The TX port auto-senses connection speed, auto-negotiates half/full duplex modes and auto-selects MDIX media type. The fiber connectors come with multimode or single mode, SC, ST, or SFP connectors to provide the necessary connection interface and distance
capabilities. LevelOne has designed 19” racks to organize media converters the smart way by providing a single power supply. With With plug-and-play technology, the converter is easy to set up and run. For a simple, cost- effective network design, the LevelOne converter series is the perfect solution to bridge the complex network infrastructure.

Features

Fast Ethernet Module

  • Comply with IEEE 802.3, 802.3u, and 802.3x standards.
  • Convert between UTP cabling and Fiber-optic cabling.
  • One RJ-45 connector, Auto-MDI/MDIX for UTP port.
  • Support 10/100 Mbps Auto-negotiation for UTP port.
  • Fiber cabling connectivity up to 40 km.
  • Store-and-forward switching to separate two collision domains. One fiber connector (SC/ ST) for 100Base-FX.
  • 2 DIP-switches to set the operation mode
  • Link- Lost-Forwarding function.

Gigabit Ethernet Module

  • Comply with IEEE 802.3, 802.3u and 802.3x, IEEE 802.3ab
  • 1000BaseT, 802.3z 1000Base SX/LX standards.
  • Convert between UTP cabling and Fiber-optic cabling.
  • One RJ-45 connector, Auto-MDI/MDIX for UTP port.
  • Support 10/100/1000 Mbps Auto-negotiation for UTP port
  • Fiber cabling connectivity up to 80 km.
  • Store-and-forward switching to separate two collision domains.
  • One fiber connector (SC / SFP) for 1000Base-SX/LX
  • DIP-switches to set the operation mode function.
  • Link- Lost-Forwarding function.

Hardware Description

Front Panel

FVT-2001 / FVT-2002 / FVT-2201 / FVT-2401 / FVT-2202

  1. RJ-45 Port (3) Fiber/SFP Connector
  2. LED Indicators (4) DIP-Switch

Rear Panel

Model No. Power Adapter
FVT-2001 DC 5V, 1A
FVT-2002 DC 5V, 1A
FVT-2201 DC 5V, 1A
FVT-2202 DC 5V, 1A
FVT-2401 DC 5V, 1A
GVT-2000 DC 5V, 2A
GVT-2001 DC 5V, 2A
GVT-2002 DC 5V, 2A
GVT-2003 DC 5V, 2A

LED Indicators
Fast Ethernet Module

LED Status Meaning
PWR On Power on
FX On 100Mbps Fiber Speed

TX

| On| 100Mbps UTP Speed
OFF| 10 Mbps UTP Speed


FDX

| On| Converter works in the full duplex mode
OFF| Converter works in the half duplex mode



L/A UTP(right)

| ****

On

| Connection status display for fiber link. “ON” indicates that Fiber link is in correct connection.
Blinks| Active status display of fiber link

“Blink” indicates packet goes through FX end.



L/A Fiber(left)

| ****

On

| Connection status display for electric link. “ON” indicates that electric link is in correct connection.
Blinks| Active status display of fiber link

“Blink” indicates packet goes through TX end

Gigabit Ethernet Module

LED Status Meaning
PWR On Power on
1000 On 1000Mbps UTP Speed
100 On 100Mbps UTP Speed

FDX

| On| Converter works in the full duplex mode
Off| Converter works in the half duplex mode


L/A UTP(right)

| ****

Blinks

| ****

Active status display of electrical interface link Blink” indicates packet goes through TP


L/A Fiber(left)

| ****

Blinks

| ****

Active status display of fiber interface link “Blink” indicates packet goes through FX

Note : The UTP port speed is 10Mbps when both 100 and 1000 LED indicators are “OFF”

DIP-switch
The DIP switch is used to configure the operation mode for LLF (Link Lost Forwarding) and Flow-Control function for UTP/Fiber port. The default value of the DIP switch is OFF.

Fast Ethernet Module/Gigabit Ethernet Module

No Status Description
1 ON LFP is Enable
OFF LFP is Disable
2 ON Flow-Control function ENABLED
OFF Flow-Control function DISABLED

Link Lost Forwarding
When LLF is enabled, allow UTP link failures to be reported to the fiber side and also allow Fiber link failure to be reported to the UTP side. Therefore, A link loss forward feature is provided in both UTP and Fiber side.

Flow Control Function
Flow control stops and resumes the transmission of network traffic between two connected peer nodes on a full-duplex Ethernet physical link. Controlling the flow by pausing and restarting it prevents buffers on the nodes from overflowing and dropping frames.
Note:
Please don’t change the DIP-switch setting when UTP or fiber port is transmitting or receiving data. It may cause some data errors.

Cabling

Fast Ethernet Module

  • The twisted-pair segments can be used as unshielded twisted pair (UTP) or shielded twisted pair (STP) cabling. The cable must comply with the IEEE 802.3u 100Base TX standard for Category 5. The cable between the converter and the link partner (switch, hub, workstation, etc.) must be less than 100 meters (328 ft.) long.
  • Fiber segments using multi-mode connector type must use 50 or 62.5/125 um multi-mode fiber cable. You can connect two devices up to a 2-kilometer (6,562 ft.) distance.
  • Fiber segments using single-mode connector type must use 8/125 or 9/125 um single-mode fiber cable. You can connect two devices at a distance of 40 Kilometers in full duplex operation.
  • For half-duplex operation, the recommended maximum distance is 412 meters (1,352 ft.)

Gigabit Ethernet Module

  • Using four twisted-pair, Category 5 cabling for RJ-45 port connection. The cable between the converter and the link partner (switch, hub, workstation, etc.) must be less than 100 meters (328 ft.) long.
  • Fiber segment using multi-mode connector type must use 50 or 62.5/125 um multi-mode fiber cable. You can connect two devices up to 550m distances.
  • Fiber segments using single-mode connector type must use 8/125 or 9/125 um single-mode fiber cable. You can connect two devices in a distance of 80 Kilometers in full duplex operation.
  • For half-duplex operation, the recommended maximum distance is 412 meters (1,352 ft.)

Optical Fiber

Module Name| Wavelength| Avg. Launch Power| Avg. Sensitivity
---|---|---|---
100Base-FX Fiber SC MM| 1310 (nm)| >-21dBm| -31dBm
100Base-FX Fiber ST MM| 1310 (nm)| >-21dBm| -31dBm
100Base-FX Fiber SC SM 20KM| 1310 (nm)| >-15dBm| -34dBm
100Base-FX Fiber SC SM

40KM

| 1310 (nm)| >-10dBm| -37dBm
100Base-FX Fiber SC SM

20KM

| 1310/1550

(nm)

| >-10dBm| -34dBm
1000Base-SX Fiber SC MM| 850 (nm)| >-10.5dBm| -20dBm
1000Base-SX/LX Fiber SC SM 20KM| 1310 (nm)| >-8dBm| -23dBm
1000Base-SX/LX Fiber ST SM 20KM| 1310 (nm)| >-8dBm| -23dBm


Module Name

| Avg. Power Loss Budget| Max. FDX

Fiber

Distance

| ****

Fiber Size (um)

---|---|---|---
100Base-FX Fiber SC MM| 10 (dBm)| 2 (Km)| 62.5/125

50/125

100Base-FX Fiber ST MM| 10 (dBm)| 2 (Km)| 62.5/125

50/125

100Base-FX Fiber SC SM| 19 (dBm)| 20(Km)| 9/125

8/125

100Base-FX Fiber SC SM| 27 (dBm)| 40(Km)| 9/125

8/125

100Base-FX Fiber SC

SM1310/1550 (nm)

| 24 (dBm)| 20(Km)| 9/125

8/125

1000Base-SX Fiber SC MM| 9.5 (dBm)| 550 (m)| 62.5/125

50/125

1000Base-SX/LX Fiber SC SM| 15 (dBm)| 20(Km)| 9/125
1000Base-SX/LX Fiber ST SM| 15 (dBm)| 20(Km)| 9/125

Specification
Fast Ethernet Module


Standard

| IEEE802.3 10BASE-T

IEEE802.3u 100BASE-TX/100BASE-FX

IEEE802.3x Flow Control and Back pressure

---|---


Connector

| Fiber: Duplex ST/SC

RJ-45 Socket: CAT-3/5 (10/100Mbps)

Twisted Pair cable, Auto MDI/MDI-X, Auto-Negotiation

Switch architecture| Store and Forward



Fiber parameters

| Fiber Core: Multi-Mode (62.5/125um, 50/125um) Single-Mode (8/125um, 9/125um)

Wavelength: 1310nm(Multi-mode)

1310nm(Single-mode) 1310/1550nm(Single-mode fiber)

Fiber Distance: Multi-Mode Fiber 2KM

Single-Mode Fiber (20KM or 40KM)

Transparent packet| 64 to 1600 Bytes for Non-VLAN Ethernet packet


Link Fault Pass through

| UTP ➔ Fiber: If UTP port link down, then converter will forced fiber to link down.

Fiber ➔ UTP: If Fiber port link down, the media converter will force UTP port to link down.


DIP Switch

| DIP Switch 1: LFP function

DIP Switch 2: Flow-Control function

LED| Power, UTP (100Mbps, L/A, FDX) Fiber (L/A, 100Mbps)
Power| DC5V, 1A
Dimension| 71mm x 94mm x 26mm
EMI & safety| CE, FCC Class A

Gigabit Ethernet Module


Standard

| IEEE802.3 10BASE-T IEEE802.3u 100BASE-TX IEEE 802.3ab 1000BaseT

IEEE 802.3z 1000BaseSX/LX standards

IEEE802.3x Flow Control and Back pressure

---|---


Connector

| Fiber: SC / SFP

RJ-45 Socket: CAT-5 (10/100/1000 Mbps or pure 1000Mbps)

Twisted Pair cable, Auto MDI/MDI-X, Auto-Negotiation

Switch

architecture

| Store and Forward


Fiber parameters

| Fiber Core: Multi-Mode (62.5/125um, 50/125um) Wavelength: 850nm(Multi-mode)

1310nm(Single-mode) Fiber Distance: 550M (Multi-Mode Fiber)

Transparent packet| 64 to 9000 Bytes for Ethernet packet


Link Lost Forward

| UTP ➔ Fiber: If UTP port link down, then converter will forced fiber to link down.

Fiber ➔ UTP: If Fiber port link down, the media converter will

force UTP port to link down.

DIP Switch| DIP Switch 1: LFP function

DIP Switch 2: Flow-Control function

LED| Power, UTP (L/A, 100Mbps, 1000Mbps, FDX)

Fiber (L/A)

Power| DC5V, 2A
Dimension| 71mm x 94mm x 26mm
EMI & safety| CE, FCC Class A

Optional SFP Modules
CVH-2000 supports 3.3V mini-GBIC module


Standard

| IEEE802.3 10BASE-T IEEE802.3u 100BASE-TX IEEE 802.3ab 1000BaseT

IEEE 802.3z 1000BaseSX/LX standards

IEEE802.3x Flow Control and Back pressure

---|---


Connector

| Fiber: SC / SFP

RJ-45 Socket: CAT-5 (10/100/1000 Mbps or pure 1000Mbps)

Twisted Pair cable, Auto MDI/MDI-X, Auto-Negotiation

Switch

architecture

| Store and Forward


Fiber parameters

| Fiber Core: Multi-Mode (62.5/125um, 50/125um) Wavelength: 850nm(Multi-mode)

1310nm(Single-mode) Fiber Distance: 550M (Multi-Mode Fiber)

Transparent packet| 64 to 9000 Bytes for Ethernet packet


Link Lost Forward

| UTP ➔ Fiber: If UTP port link down, then converter will forced fiber to link down.

Fiber ➔ UTP: If Fiber port link down, the media converter will

force UTP port to link down.

DIP Switch| DIP Switch 1: LFP function

DIP Switch 2: Flow-Control function

LED| Power, UTP (L/A, 100Mbps, 1000Mbps, FDX)

Fiber (L/A)

Power| DC5V, 2A
Dimension| 71mm x 94mm x 26mm
EMI & safety| CE, FCC Class A

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals