VULCAN C24EA Series Electric Convection Steamers Instruction Manual

June 12, 2024
Vulcan

C24EA SERIES ELECTRIC CONVECTION STEAMERS – ELECTRICAL OPERATION

LEGEND OF ELECTRICAL SYMBOLS

           TERMINAL BLOCK (TB)

                FUSE (FU)

           SWITCH, SPDT

            SWITCH, N.O.

          THERMOSTAT, N.O.

         PRESSURE SWITCH, N.C.

         CONTACTS, N.C.

         CONTACTS, N.O.

             WATER PROBE ASSEMBLY

    LIGHT
AM-AMBER
GN = GREEN
RD = RED

N.C = NORMALLY CLOSED
N.O = NORMALLY OPEN

   TIME DELAY RELAY

         SOLENOID (SOL)

        DRAIN VALVE, MOTORIZED

       DELIME VALVE, MOTORIZED

       COIL, RELAY (K) OR CONTACTOR

  TRANSFORMER (T)

COOKING TIMER

WATER LEVEL CONTROL(WLC)

19222

Fig. 81

C24EA 6 & 10 SCHEMATIC
208V/240V/480V

MAIN TRANSFORMER CONNECTIONS


H1 – – – – – – COM
H2 – – – – – – 208V
H3 – – – – – – 240V
H4 – – – – – – 480V

1FU 8 2FU = 3A (SLOW BLOW)

AI2107

Fig. 82

DERIVED 857305-1
FROM:          REV. C

** SEE HEATING ELEMENT WIRING DIAGRAMS FOR K10 AND K12 CONTACTS

AI2108

Fig. 83

208V 3 PHASE

SEE FIELD CONVERSION NOTES FOR 240V

|

QUANTITY

---|---

ITEM

| DESCRIPTION|

6 PAN

|

10 PAN

1

| TERMINAL BLOCK|

1

|

1

2

| LIMITING CONTACTOR|

1

|

1

3

| REGULATING CONTACTOR|

2

|

2

4

| GENERATOR HEATING ELE.|

2

|

3

5

| HEAT EXCHANGER ELE.|

2

|

0

| HEAT EXCHANGER ELE.|

0

|

2

6

| RELAY|

2

|

2

7

| GROUND LUG|

1

|

1

DERIVED FROM:
857316-1 REV C


FIELD CONVERSION NOTES

6 PAN MACHINES USE TWO GENERATOR HEATING ELEMENTS. ONE ELEMENT BETWEEN THE LIMITING CONTACTOR AND REGULATING CONTACTOR 1, IS NOT PRESENT

FOR 6 PAN MACHINES, TO CONVERT TO 240V, DISCONNECT THE BLACK ELEMENT LEAD FROM REGULATING CONTACTOR 2 AND ITS CORRESPONDING LEAD FROM THE LIMITING CONTACTOR. MOVE THE MAIN TRANSFORMER PRIMARY INPUT FROM THE H2 (208V) POSITION TO THE H3 (230V) POSITION

FOR 10 PAN MACHINES, TO CONVERT TO 240V, DISCONNECT THE BLACK ELEMENT LEAD FROM REGULATING CONTACTOR 2 AND THE WHITE ELEMENT LEAD FROM REGULATING CONTACTOR 1 AND THEIR CORRESPONDING LEADS FROM THE LIMITING CONTACTOR. MOVE THE MAIN TRANSFORMER PRIMARY INPUT WIRE #4 FROM THE H2 (208V) POSITION TO THE H3 (230V) POSITION

AI2109

Fig. 84

208V 1 PHASE

SEE FIELD CONVERSION NOTES FOR 240V

|

QUANTITY

---|---

ITEM

| DESCRIPTION|

6 PAN

|

10 PAN

1

| TERMINAL BLOCK|

1

|

1

2

| LIMITING CONTACTOR|

1

|

1

3

| REGULATING CONTACTOR|

2

|

2

4

| GENERATOR HEATING ELE.|

2

|

3

5

| HEAT EXCHANGER ELE.|

2

|

0

| HEAT EXCHANGER ELE.|

0

|

2

6

| RELAY|

2

|

2

7

| GROUND LUG|

1

|

1

DERIVED FROM:
857316-1  REV C


FIELD CONVERSION NOTES

6 PAN MACHINES USE TWO GENERATOR HEATING ELEMENTS. ONE ELEMENT BETWEEN THE LIMITING CONTACTOR AND REGULATING CONTACTOR 1, IS NOT PRESENT

FOR 6 PAN MACHINES, TO CONVERT TO 240V, DISCONNECT THE BLACK ELEMENT LEAD FROM REGULATING CONTACTOR 2 AND ITS CORRESPONDING LEAD FROM THE LIMITING CONTACTOR. MOVE THE MAIN TRANSFORMER PRIMARY INPUT FROM THE H2 (208V) POSITION TO THE H3 (230V) POSITION

FOR 10 PAN MACHINES, TO CONVERT TO 240V, DISCONNECT THE BLACK ELEMENT LEAD FROM REGULATING CONTACTOR 2 AND THE WHITE ELEMENT LEAD FROM REGULATING CONTACTOR 1 AND THEIR CORRESPONDING LEADS FROM THE LIMITING CONTACTOR. MOVE THE MAIN TRANSFORMER PRIMARY INPUT WIRE #4 FROM THE H2 (208V) POSITION TO THE H3 (230V) POSITION

SINGLE PHASE MACHINES HAVE WIRE #1 ON L3 OF REGULATING CONTACTOR 1 RATHER THAN L1 OF THE LIMITING CONTACTOR

AI2110

Fig. 85

480V 3 PHASE

|

QUANTITY

---|---

ITEM

| DESCRIPTION|

6 PAN

|

10 PAN

1

| TERMINAL BLOCK|

1

|

1

2

| LIMITING CONTACTOR|

1

|

1

3

| REGULATING CONTACTOR|

2

|

2

4

| GENERATOR HEATING ELE.|

2

|

3

5

| HEAT EXCHANGER ELE.|

2

|

0

| HEAT EXCHANGER ELE.|

0

|

2

6

| RELAY|

2

|

2

7

| GROUND LUG|

1

|

1

DERIVED FROM:
857316-2  REV C

FIELD CONVERSION NOTE

6 PAN MACHINES USE TWO GENERATOR HEATING ELEMENTS. ONE ELEMENT BETWEEN THE LIMITING CONTACTOR AND REGULATING CONTACTOR 1, IS NOT PRESENT