noaton DF 4114 Air Dehumidifier Instruction Manual
- June 4, 2024
- Noaton
Table of Contents
INSTRUCTION MANUAL
Norton DF 4114
Air dehumidifier
DF 4114 Air Dehumidifier
Read the
instructions for use. Read the relevant section in this User Guide before any
use.
This product must not be disposed of with other household waste at the end of
its useful period, but must be taken to a collection point designated for the
recycling of electrical equipment.
The product complies with applicable European and other directives.
The product uses flammable refrigerant for its function. If the refrigerant
escapes from the unit and comes into contact with an open flame or another
strong heat source, there is a risk of fire.
Parameters are subject to change. For the latest version of the manual, please
visit the manufacturer’s website.
Verze: DF_4114-09-2022-EN
Safety instructions
Read the instructions carefully before using the dehumidifier.
- Install the unit on a level and solid floor to reduce vibration or noise.
- Never immerse the unit in water or other liquids.
- Never use the instrument if the cable or other connector is damaged or something unusual occurs. In this case, please contact customer service.
- Disconnect the instrument from the power supply when it is not in use, being moved, or being cleaned.
- Use the instrument according to the specified voltage.
- The instrument is intended for indoor use only. Do not use it for other purposes.
- Do not place heavy objects on the instrument.
- Do not tilt the unit to any side, water may spill out of the unit and damage it.
- Never insert any objects into the interior of the instrument to prevent damage to the instrument.
- Do not place the unit near heat-generating equipment or flammable or hazardous materials.
- This appliance is not intended for use by persons (children) with reduced physical or sensory abilities or lack of experience unless they have been given safety instructions on how to operate the appliance or are working under the supervision of a person responsible for their safety. Children must be supervised by an adult and should not handle the apparatus.
- If the power cord is damaged, it must be replaced by the manufacturer, its service representative, or a similarly qualified person to avoid the risk of injury.
- The appliance must be positioned so that the plug is accessible.
- The appliance must be installed in accordance with national wiring regulations.
- The ambient temperature range for the appliance is 5 °C – 35 °C.
Do not attempt to repair, disassemble or make modifications to the appliance,
failure or damage may occur. Even the actual replacement of the power cord
should only be carried out by a specially qualified person.
Warning in relation to R290 refrigerant
This equipment is designed to use only R290 (propane) refrigerant, which is
hermetically sealed under pressure in the refrigeration circuit. Repairs to
this equipment may only be carried out by a specially trained service
technician in accordance with national legislation relating to flammable
substances! Do not tamper with the cooling circuit, pierce it or expose it to
higher temperatures.
Do not release refrigerant into the atmosphere.
Do not try to speed up the defrosting process in any way (e.g. by heating).
The appliance must be placed in a room of at least 4 m2.
R290 is a flammable gas (propane) and is heavier than air. For this reason,
its concentration rises most near the ground during a leak, but it can be
agitated (e.g. by drafts, fans, etc.) to higher layers. The propane used in
this equipment is an odorless gas.
Do not use the unit in a room with an open flame or another strong source of
heat (such as cigarettes, candles, etc.) or electrical discharges. Place the
appliance in a room that can be ventilated if necessary and where gas
accumulation is not possible. If propane is detected or even suspected in the
room, do not allow unauthorized persons to search for the location of the
leak. In this case, evacuate all persons from the room, open the windows,
vacate the room, and notify the local fire station of the propane leak. Do not
allow any person to return to the room until the fire department commanding
officer or a certified service technician has determined that the hazard has
passed.
FAILURE TO FOLLOW THE ABOVE INSTRUCTIONS MAY RESULT IN FIRE, EXPLOSION,
PROPERTY DAMAGE, INJURY, OR DEATH.
Features
Powerful dehumidification
Using compressor technology, this dehumidifier removes excessive humidity in
the room.
Compact and portable design
The simple design of the dehumidifier and its low weight guarantee very easy
and effortless handling.
The low-temperature operation, automatic defrost
If the ambient temperature is between 5 degrees Celsius and 16 degrees
Celsius, the unit will automatically defrost at regular intervals. During the
defrost phase, the compressor
will not operate, but the operation of the fans will not be affected. During
defrosting, the ambient humidity indicator will be blue.
Three dehumidification modes
Three types of dehumidification modes are available for users: sunny, rainy
and continuous dehumidification (laundry drying). The user can also select a
target humidity.
Low noise and energy saving
Based on the “smart home” concept, this dehumidifier uses special energy-
saving technology, plus its low noise level provides users with a comfortable
home experience.
Air purification
This unit uses a carbon filter to clean the air in the room. Among the
cleaning functions, it uses a double-start method that can dehumidify and
clean at the same time.
Parameters
Power source | 220V-240V/50Hz |
---|---|
**** Energy consumption | 180W (30℃,80%RH) |
156W (27℃,60%RH)
* Rated current| 0.95 A (30℃,80%RH)
0.88 A (27℃,60%RH)
Dehumidification capacity| 13.5 L/den (32℃, 90%RH)
12 L/den (30℃,80%RH)
6.8 L/den(27℃,60%RH)
Power efficiency (27℃,60%RH)| 1.781
Noise level| Min. 40 dB
Max. 44 dB
Air flow max.| 120m3/h
Tank capacity| 2L
Refrigerant type/quantity| R-290 / 0,06kg
GWP coefficient| 3
CO2 equivalent| 0,00018 t
Operating temperature| 5℃-35℃
Recommended room size| 15~25m² (Ceiling height =2.6m)
Control type| Touch panel
Automatic defrosting| Yes
Automatic shutdown when the tank is full| Yes
---|---
Automatic humidity maintenance| Yes
Restart and preserve settings during a power failure| Yes
Timer (delayed start, delayed shutdown)| 0-24 h
Division of the device| 280200500mm
Division of the package| 330250*565mm
Weight of the device| 12 kg
Weight of the package| 13 kg
Drain through hose| Yes
Minimum room size**| 4 m2
Appearance
Before starting
Filter installation
- Remove the carbon filter from the plastic bag.
- Remove the air intake pre-filter grille.
- Insert the filter on the inside of the grille, the filter is inserted correctly if the black (carbon) side faces out of the unit.
- Now replace the grille with the air intake pre-filter.
- The average lifetime (depending on air pollution) of carbon filters under normal use (approx. 8 hours per day) is approximately 6-12 months.
Proper placement
When the dehumidifier is in operation, make sure that the rear of the
dehumidifier has a minimum distance of 20 cm from walls or furniture as shown
below.
Features (Control panel)
Switching on the dehumidifier
When the unit is first plugged in, a beep sounds, and “–” appears on the
display. The device then enters standby mode. When the “on/off” button is
pressed, the button will light up and the display will show the current
ambient humidity and start in sunny mode (automatically maintaining 60% RH and
high fan speed).
Humidity settings
Press the humidity button (“HUM”) and select the target humidity using the
same button (every single press increases the humidity by 5%).
Full tank indicator
When the water tank is full, the “full tank” light will turn red and the
device will beep 3 times to alert the user to empty the water tank. At this
point, the compressor and fan will
turn off and the dehumidifier will switch to the “full tank” state. When the
tank is emptied and returned to its original location, the unit will
automatically switch to the previous
setting.
Turning off the full tank warning
When the water tank is full of water, the beeping can be canceled by pressing
any button, but the “full water tank” status cannot be switched off.
Pouring out the water tank
- Grasp the water tank with your hand on the underside of the water tank and pull it out of the body of the device. CAUTION – If the water tank is removed abruptly, water may spill.
- Empty the water tank.
- Put it back in its original place.
Button control
Turn-on/Turn-off
First, start-up – press the “on/off” button to turn on, the operation
light around this button will light up and the unit will be set in sunny mode
(automatically maintaining 60% RH and high fan speed). If the ambient humidity
is less than 60% RH when the unit is first turned on, dehumidification will
not start. If the “on/off” button is pressed while the unit is on, the
operation light will go out and the compressor will immediately stop and the
fan will turn off after approximately 30 seconds.
Restart – when the device is switched off with this button and switched
on again, the previous settings are retained (if the cable of this device has
not been unplugged). If the “on/off” button is pressed while the unit is on,
the operation light will go out and the compressor will immediately stop and
the fan will turn off after approximately 30 seconds.
Humidity button (“HUM”)
Tap the humidity button (“HUM”) to check the current ambient humidity, after
touching this button again to adjust the humidity. Each time this button is
pressed, a beep sounds, the display lights up and the target humidity value is
increased once by 5%. The target humidity range is 20% – 25% – 30% – 35% – 40%
– 45% – 50% – 55% – 60% – 65% – 70% – 75% – 80% – 85% – 90% – 95%. Three
seconds after setting, the system confirms the input value and the instrument
displays the current humidity value. The target humidity cannot be changed in
the continuous dehumidification (clothes drying) mode. Long press the humidity
button for 5 seconds to display the current ambient temperature.
Timer („TIMER“)
Press the timer button to set the 0-24 hour timer function. Each time the
press this button, the value will increase by 1 hour and the screen will
display the corresponding timing value. Setting “00” will cancel the timer
function and the button will turn off. If the button is lit, a value other
than “00” is set. In the operating state, set the timer to turn off the
instrument; if you set the timer in standby mode, the instrument will then
start in the last set mode.
Sleep mode („SLEEP“)
Press this button, which will then light up and start the sleep function.
After inactivity, all indicators will gradually darken and the fan speed will
automatically switch from high to low speed. Tapping any button causes the
indicators to light up again. Press the sleep button again to exit sleep mode.
In this mode, the full tank alarm is switched off.
Mode button („MODE“)
Press once to switch from one mode to the other, then the corresponding
indicator lights up.
Sunny mode: The default target humidity is 60% when the machine is
running, and the target humidity can be set, but the mode will turn off when
it is changed.
Rain mode: the default target humidity is 40% when the machine is running
and the target humidity can be set, but the mode will turn off when it is
changed.
Continuous dehumidify mode: the machine dehumidifies regardless of the
ambient humidity, but the target humidity cannot be set.
Fan speed button/child lock (“SPEED/LOCK”)
Fan speeds – high and low
Press the button once to switch the speed and then the corresponding indicator
will light up. The fan speed cannot be switched in sleep mode and during the
defrost phase. Long press this button for 3 seconds to switch the child lock
function on/off.
Indicators
Ambient humidity indicator
When the dehumidifier is switched on, the light ring around the on/off button
appears in different colors according to the current and ambient humidity.
Colour | Ambient humidity (lit) | Status (flashing) |
---|---|---|
Blue | 0% – 39% | Defrosting |
Green | 40% – 59% | – |
Red | 60% – 100% | The water tank is almost full |
Full tank indicator
When the water tank is full, the indicator light will turn red, the compressor
and fan will stop working and 3 beeps will sound simultaneous to remind the
user to empty the water in the tank. In sleep mode, the audible warning is
inactive.
When you select the sunny mode, this indicator will light up.
When you select the rain mode, this indicator lights up.
This indicator lights up when you select the continuous dehumidification mode
(laundry drying).
If you set the fan speed to low, this indicator will light up.
If you set the fan speed to low, this indicator will light up.
The child lock indicator lights up when the child lock function is switched
on.
Continuous hose outlet
Water is collected in the tank, if you want to use a continuous drain hose, proceed as follows:
- Remove the water tank.
- Attach the drain hose (included) to the hose connection (10 mm diameter). Always make sure that the hose is pointing downwards and is not blocked or kinked.
- Put the water tank back into the device
Compressor running and stopping conditions
If the ambient temperature is <5°C or the ambient temperature is >35°C or the
humidity sensor fails, the compressor does not work.
When the ambient temperature is 5°C ≤ ambient temperature ≤ 16°C, the
compressor automatically defrosts at intervals; during defrosting, the
compressor does not work, and The fan still works.
Memory functions
- When the power cord is disconnected from the mains or when the power fails and the power is reconnected, the dehumidifier will operate in pre-shutdown mode. The timer setting will be canceled.
- Press the on/off button to turn the dehumidifier off and then turn it back on by pressing the same button. The dehumidifier will operate in pre-shutoff mode. The timer setting will be canceled.
- Turn the unit off and disconnect the power cord, reconnect the power and turn the dehumidifier on. The unit will return to the original factory settings.
- The delayed start setting will be canceled if the power cord is disconnected from the mains or if there is a power failure.
Maintenance
Cleaning the water tank
- Do not remove the float. If the float is removed from the tank, the unit will not turn on.
- If the tank is dirty, wash it with warm water. Do not use detergents or scouring pads, chemically treated anti-dust cloths, gasoline, benzene, thinners, or other solvents as they may damage the water tank and cause leakage!
- When inserting the water tank, push it into the unit with both hands and insert it into the correct position. If the tank is not in the correct position, the appliance will not switch on.
Cleaning the instrument and pre-filter
- Before cleaning, switch off the appliance, then pull the plug from the socket.
- Clean the cover with a soft dry cloth. If the device is very dirty, use mild detergents. Wipe the dehumidifier with a damp cloth. Water must not get inside the unit.
- Remove the pre-filter from the back of the unit, and clean it with a vacuum cleaner or soapy water, no warmer than 40°C.
- Dry the pre-filter thoroughly before returning it to the instrument.
Cleaning the carbon filter
Remove the carbon filter and clean it with a vacuum cleaner. This filter must
not come into contact with water.
Storage
- If the dehumidifier will not be used for a long period of time, please follow these instructions:
- Turn off the machine and remove the plug from the socket. Empty the tank and completely drain it and the dehumidifier. To ensure that the inside of the unit is completely dry, place it in a dry place for 2-3 days.
- Clean the filters.
- Check that the dehumidifier is in good condition to ensure it is safe to use after extended storage.
- Wrap the equipment in suitable packaging.
- Store the dehumidifier in a dust-free and dry environment, out of direct sunlight, preferably covered with plastic sheeting.
Troubleshooting
Before you contact a service professional, read this list. It may save you costs and time. This list includes common cases that are not the result of a defect in workmanship or materials.
Problem | Possible cause | Solution |
---|---|---|
The device is not working | Power not connected | Drain the water tank or place |
the water tank in the correct
position
The water tank has not been fitted correctly or is full. If the ambient
temperature is less than 5 degrees (the| Drain the water tank or place the
water tank in the correct
position
the display shows the message “CL”)
Greater than 35 degrees (the display shows the message “CH”)| For safety
reasons, the device will not work in such conditions.
The dehumidification function is not working properly| Is the air filter
clogged?| Clean the air filter as instructed
The air outlet is blocked or the intake?| Remove the obstacle preventing
airflow.
Loud sound when running| Is the machine placed on a flat surface?| Place the
device on a flat surface
---|---|---
Are the filters clogged?| Clean the filters according to the instructions
E2| Problem with the humidity sensor| Disconnect the device and reconnect it,
if the problem persists, contact professional service.
The screen displays “L0”| Ambient humidity is below 20%| Work in elevated
humidity
The screen will display “HI”| Ambient humidity is higher than 95%| High
humidity occurs
The screen will display “CL”| Protection against low-Temperature protection,
ambient temperature <5 ° C| Increase the ambient temperature
The screen will display “CH”| High-temperature protection, ambient temperature
35°C| Reduce the ambient temperature
Disposal
The crossed-out bin icon on electrical and electronic waste indicates that
the equipment must not be disposed of with household waste at the end of its
life. This waste must be disposed of in accordance with the applicable local
legislation by taking it to selected e-waste collection points near your home.
Contact your local authority for the exact addresses of such sites. Sorting
e-waste helps to reuse, recycle or gently dispose of hazardous substances,
thereby protecting the ecosystem and, consequently, human health.
The refrigerant in the appliance must be disposed of in accordance with the
applicable local ordinances and by a company that is certified for this type
of activity (European Waste Catalogue 160504).
GAVRI S.R.O.
SLUNEČNÁ 6, BRNO
63400
CZECH REPUBLIC
WWW.GAVRI.CZ
Documents / Resources
|
noaton DF 4114 Air
Dehumidifier
[pdf] Instruction Manual
DF 4114, Air Dehumidifier, DF 4114 Air Dehumidifier
---|---
References
- Stropní ventilátory, mobilní klimatizace, odvlhčovače vzduchu, čističky vzduchu, zvlhčovače vzduchu | Gavri.cz
- Stropní ventilátory, mobilní klimatizace, odvlhčovače vzduchu, čističky vzduchu, zvlhčovače vzduchu | Gavri.cz