Photovoltaic Module

Safety instructions
Please follow these safety instructions closely to prevent accidents and material losses

Safety instructions explained
Note Details identified by the word “Note” contain additional information.

Installation, commissioning, inspection, maintenance and repairs must only be carried out by an authorised, competent person (heating engineer/installation contractor).

Before working on the appliance/heating system, isolate it from the power supply (e.g. by removing a separate mains fuse or by means of a mains isolator) and safeguard against unauthorised reconnection.

Wear suitable personal protective equipment when carrying out any work.

Repairing components that fulfil a safety function can compromise the safe operation of the system. For replacements, use only original spare parts supplied or approved by Viessmann. Install the components with new gaskets.

Dimensions

Fig: 1
Dimensions

A Junction box
B Connecting cables
C 4 drilled holes 9 x 14 mm
D 4 holes for equipotential bonding, 7 6 mm

a mm 1719
b mm 1140
c mm 1100
d mm 1031
f mm 30
g mm 30

Mounting guidelines

fig:2
Dimensions

Clamping area Max. load due to
pressure suction
A 5400 Pa(551 kg/m2)
B 1800 Pa(184 kg/m2)
C 2400 Pa(245 kg/m2)
D If using A and D together
12000 Pa(1224 kg/m2) 3200 Pa(326 kg/m2)

Note
Clamping area D only if secured with 3 rails

Specification

Performance data under STC (standard test conditions)

Vitovolt 300| Type| M400WK| M405WK| M410WK| M415WK| M420WK
---|---|---|---|---|---|---
Rated output Pmax.| WP| 400| 405| 410| 415| 420
Output tolerance| W| 0/+5| 0/+5| 0/+5| 0/+5| 0/+5
MPP voltage Umpp| V| 38.6| 38.7| 38.8| 38.9| 39.0
MPP current Impp| A| 10.36| 10.47| 10.57| 10.67| 10.77
Open circuit voltage Uoc| V| 46.4| 46.5| 46.6| 46.7| 46.8
Short circuit current Isc| A| 10.97| 11.02| 11.07| 11.12| 11.17
Module efficiency| %| 20.41| 20.66| 20.92| 21.17| 21.43

For measuring tolerances, see datasheet

  • Standard test conditions (STC):
  • Insolation: 1000 W/m3
  • Cell temperature: 25 °C
  • Air mass: AM 1.5

Commissioning

“Vitovolt” installation and service instructions

Viessmann Climate Solutions SE 35108 Allendorf / Germany
Telephone: +49 6452 70-0
Fax: +49 6452 70-2780
www.viessmann.com

Scanner & Pdf
Qr Code
https://link.viessmann.com/technical- documents?documentNumber=6198490&version=1&country=GB&language=en&documentType=VMA

Viessmann Limited Hortonwood 30, Telford Shropshire, TF1 7YP, GB
Telephone: +44 1952 675000
Fax: +44 1952 675040
E-mai l: info-uk@viessmann.com

viessmann Logo

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

VIESSMANN User Manuals

Related Manuals