EXCELL X Series Weighing Scale User Manual

June 13, 2024
EXCELL

EXCELL PRECISION CO.,LTD.
X Series Weighing Scale

User Manual
02036XXX
ZSME300000422

© EXCELL PRECISION CO., LTD. All rights reserved worldwide.
The information contained herein is the property of EXCELL PRECISION CO., LTD. and is supplied without liability for errors or omissions. No part may be reproduced or used except as authorized by contract or other written permission. The copyright and the foregoing restriction on reproduction and use extend to all media in which the information may be embodied.
Check Firmware Version
Turn on scale and hold ZERO key during countdown. Display firmware version 02036.
Turn off scale and turn on scale and hold TARE key during countdown. Display maintenance number XXX, which is ranged from 0~999. Turn off and turn on scale to return to weighing mode.
Thank for your purchasing of our EXCELL Weighing Scale. To guide you to use our product correctly, please read this User Manual carefully to extend the life of machine and to avoid error.

Preparing to Use the Scale

  1. Locate the scale on a firm level surface free from vibrations for accurate weight readings.
    Adjust the four leveling feet to centre the leveling bubble on the scale.

  2. Avoid hot sunshine directly on the scale or near the exhaust port of ventilating system.

  3. Please use a separate power source plug to avoid the disturbance of other electric appliances.

  4. There should be no weight on the scale when power is turned on.

  5. Commodity should be placed at the centre of platter when being weighed, and its size should not exceed the dimension of the platter.

  6. Please warm the scale 15 ~ 20 minutes before using.

  7. Please note that when symbol appears on the screen, the scale needs to be charged.

  8. Any suggestion is warmly welcome.

Precautions for Use

  1. Please operate or charge the scale in an open area. Do not squeeze the power cord to avoid wire on fire.
  2. Please keep scale in a cool and dry place. Do not store under high temperatures.
  3. Please keep the scale clean and free from insect infestation.
  4. Avoid impacting with other items or overloaded with excessively heavy weights (The load must not exceed the maximum capacity of the scale).
  5. If the scale is not going to be used for some time, please clean it and store it in a plastic bag in dry condition. A desiccant sachet may be included to prevent moisture from building up.
  6. Operating temperature: -10℃ ~ + 40℃
  7. It is recommended to be used indoors and in environments with a height of less than 2000m
  8. If the product is used in a manner not specified by the manufacturer, product warranty may be limited.

Safety Instructions for Lithium Batteries

  1. Please pay attention to the storage temperature of the product. Do not place it in a high temperature environment. The ambient temperature should be less than 50C.

  2. After installing the battery, if no display when power is turned on, please check whether the battery polarity is reversed. The polarity must be installed correctly to avoid battery power wasted away.

  3. When the LED flashes in the charging state, it means there are the following abnormal states, please check:
    a) Battery is installed but the contact is poor, please check whether the battery is installed properly.
    b) Please check whether the polarity of the battery is reversed. When the polarity is reversed, the LED will flash after charging for a period of time.
    c) When battery is removed and the AC power cord is still plugged in, the LED will also flash.
    When plugged in without the battery installed, there will be a slight frequency conversion sound, which is normal and does not affect the use of the function.

  4. When symbol appears, scale needs to be charged.
    a) When charging, the red LED will light up. Please refer to 1-4 for estimated charging hours.
    b) When the battery is fully charged, blue LED will light up.
    c) If scale is fully charged, after plugging in, the blue light will turn on after about 5~10 minutes of voltage detection. The LED charging indicator is to indicate the status of the charging process and whether the charging is working properly. To check the battery level, please unplug the AC cable first and turn on scale, and then check the battery symbol displayed in the lower left corner of the display. The number of bars under the battery symbol indicates battery level. 0 bar means <= 10% when the low power warning symbol ( ) flashes to indicate that scale needs to be charged.

  5. Please operate or charge the scale in an open area. Do not squeeze the power cord to avoid wire on fire. While charging, the temperature of battery should below 45℃.

  6. Our product uses a single-cell cylindrical 18650-3.7V lithium-ion battery. Battery’s should be 3.6~3.7V and capacity is not restricted.EXCELL X Series Weighing Scale - icon 3

  7.  If the appearance of the battery is deformed, damaged, etc., please do not install it for the safety of use.

Chapter 1 Introduction

1-1 Production Introduction

  1. High performance A/D converter
     0.3 uv/D high sensitivity
     zero point adjustable range -2mV~ +5mV
     Sampling speed 10 times/second  use range -4mV ~ +30mV
     non-linear scale 0.01% full scale
     load cell stimulate power source 5V DC ±2% 100mA

  2. According to different resolution to do linearity calibration
     Ordinary resolution models (below 10000)
    Do specification calibration first then do weight calibration
     High resolution models (10000~30000)
    Do linearity calibration first specification calibration  weight calibration at last LCD display with LED backlight, powered by battery or plug-in mains, automatic power-off function to ensure the stability of the scale. When battery voltage is lower than the system voltage, scale is automatically powered off to ensure the accuracy and stability of the scale.

  3. Check Weighing function for high limit and low limit and OK range.

  4. 4 HOLD functions including animal scale HOLD

  5. Depending on actual space, a RS232 card and/or a relay card can be installed.

1-2 Display DescriptionEXCELL X Series Weighing Scale -
Display

HI : High limit value
OK : OK range within HI and LO limits
LO : Low limit value
kg : “kg” unit
lb : “lb” unit
Pcs : Counting mode
% : Percent indication
→O← : “Zero” indication
Net : “Net weight”

indication

| :| “Low battery

power” indication

▼1 “Stable” indication
▼2 : “Pre-tare mode” indication
▼3 : (M+) “Accumulation mode” indication
▼5 : ( **** ) “Samples insufficient” indication
▼6 : (       ) “Unit weight insufficient” indication
▼7 : “Viss” unit (Burma unit)

  For Dual Range Models, the indicator 5 and 6 will be defined as below:
▼6 is Range 1 ▼5 is Range 2
1-3 Keypad Functions DescriptionEXCELL X Series Weighing Scale -
Keypad

Key description| 4/5 key| 10 key| 12 key| Other variation
---|---|---|---|---
Net/Gross key| | | | NET/GROSS
Loop select from the preset units|

UNITS

| UNITS| UNITS| lb/kg
Preset weight and quantity for weight check or quantity check| | | | TGT SET
Accumulate weight or quantity| | +| M+|
Tare to deduct the container weight| | | | TARE
Set preset tare| | | |
Recall the totalization value, preset value and pre-tare value| | | | RE-CALL
Clear the totalization value, preset value and pre-tare value.| | CE| CE|
Zero the scale.| | | | ZERO
Press this key to input the numbers (0 ~ 9) and to light up the backlight.| | | |
Press this key to print the total data and to confirm| | | | PRINT
Go into counting mode.| | | |

COUNT or Q’TY SET

Press this key to sample.| | | | SMPL

key and key are not available for 10-key models.
1-4 Power Description

Power Battery 18650 3.7V lithium battery
Plugged in 100~240V AC
Power consumption varies depending 0~100% backlight used (mA) No backlight

75% backlight (factory default)
≈ 24| ≈ 28

Scale has a built-in power saving function to extend usage time. Table below shows the battery capacity and estimated usage time. Time may vary with different brands of lithium batteries and are for reference only.

Battery capacity 2000mA 2500mA 3000mA 3200mA 3500mA
Average usage time 80~90

hours

| 95~105

hours

| 110~120

hours

| 120~130

hours

| 130~140

hours

Estimated charging time| ≈2.5 hours| ≈3 hours| ≈3.5 hours| ≈4 hours| ≈4.5 hours
Assume 25% in use for average usage time. If use continuously, time will be reduced by ~40%.

Low Power Alarm
When symbol flashes, scale needs to be charged. To check the battery level, please unplug the AC cable first, and check the battery symbol displayed in the lower left corner of the display. The number of bars under the battery symbol indicates battery level. 4 bars mean 100%, 3 bars mean 75%, 2 bars mean 50%, 1 bar means 25%, and 0 bar means <= 10% when the low power warning symbol ( ) flashes to indicate that scale needs to be charged. If not charge immediately, scale auto shuts down within 5~10 hours or 1~2 hours with backlight. The cut voltage is about 3.5V. Once it auto shuts down and enters the battery protection mode, it must be charged before it can be used again.
Please recharge at once when the symbol shows in order to keep the weight accuracy.
Charging indicator a) When charging, the red LED will light up. Please refer to 1-4 for estimated charging hours.
b) When the battery is fully charged, blue LED will light up.
c) If scale is fully charged, after plugging in, the blue light will turn on after about 5~10 minutes of voltage detection. The LED charging indicator is to indicate the status of the charging process and whether the charging is working properly. To check the battery level, please unplug the AC cable first and turn on scale, and then check the number of bars under battery symbol for battery level.
1-5 Error Messages
oL Weight exceeds 9d of maximum capacity. (d=division)
E1 Zero value after power on is over +10% FS.
E2 Zero value after power on is less than -10% FS.
need to set C5 to 1 to have E1 and E2 warnings
E4 Unstable zero return, unstable over 10 sec. Press
to leave E4.
E6 Zero is too high when calibrating. (over internal value 350,000)
E7 Zero is too low when calibrating. (under internal value 80,000)
E8 Resolution is set higher than factory setting. Send it back to us to unlock to set new resolution.
E10 The scale is not in level status.(only available with level detector equipment.)
– – – – – – For weight < -20d without tare or pretare device in operation.
OIML approval models need to set C5 to 1 to show “- – – – – -“
E10 Level Switch (option)
Make PCB J3 open circuit and connect signal to CN7 of PCB. Display shows E10 after 2 seconds and all keys stop working in the mean time. If you do not need level switch, make J3 short circuit.

Chapter 2 General Operation Description

2-1 Backlight Function
Press key to loop select the display backlight mode: Auto 1~4, bL. on, bL. oFF.
Auto 1~4 “Auto Backlight” mode. When the weight is over 10d or any key is pressed, the backlight will be switched on. When the weight returns to zero (the weight on platform is less than 10d), the display backlight will switch off after 10 seconds.
1~4 (25%~100% backlight) is the brightness selection. Default is 3 (75%).
bL. On Display backlight is on all the time.
bL. oFF Display backlight is off.
2-2 Weighing Mode
2-2-1 Units Selection (not available in 4 key model)

  1. After indicator is turned on, use UNITS key to select a unit from kg, lb, tael or viss, as the screen indicated.
  2.  The selected unit will be memorized when you turn the indicator off. And the memorized unit will appear after you turn on the indicator next time.

2-2-2 Zero Function
Press key to re-zero the display with no load on the platter. When zero is set, the ( ) symbol will be displayed.
2-2-3 Tare Function

  1. When the weight of the container is unknown ( )
    1.  Place the container on the platter, after stable and press key, the weight value returns to zero and net indication (Not ) is on.
    2. Place goods into the container, then the indicator shows the net weight of goods.
    3. Clear tare value
    When removing the container and goods, the display shows the negative weight value of the container. Then press key to clear tare value. The indicator returns to zero and net indication ( Not ) is on.
    4. Recall tare value Press then key the display shows tare value
     Multiple tare operation Users can continuously increase or decrease the tare value by pressing the key.
     The total tare value (tare value + pre-set tare value) can equal the full capacity of the indicator.

  2.  When the weight of the container is known ( )
    1.  Press key and the display shows Use and keys to input weight value of the container. After finishing the procedures, the net indication (Not ) and pretare indication “” is on.
    2.  Place goods into the container, then the indicator shows the net weight of goods.
    3. Clear pretare value Press then key, and then press CE key to clear pretare value.
    When indicator returns to zero, net indication (Not ) and pretare indication “”▼ are off.
    4.  Recall pretare value Press then key  the display shows pretare value

In Tare mode, the Preset tare function is disabled.
The indicators with two weighing ranges can NOT pre-set the tare value larger than the first weighing range. For example: a 30 kg indicator is set by two weighing ranges. The first range is 0 to 15 kg, and the second range is 15 to 30 kg. The pre-set tare value can not be larger than 15 kg.
2-2-4 Net/Gross Function (only available in 4/5 key models)
In Tare mode, press key once to display gross value. Net symbol “▼”disappears, and the gross value “▼” appears. Press key again, it displays net value, net symbol “▼” appears and gross symbol “▼” disappears. Press key continually to display net value or gross value. In tare mode, key is able to work. When it displays “▼”, all keys are disable except .
2-2-5 Check Weighing Mode (4/5 key models need to set through F4)

  1. Preset “ High limit”, “Low limit” and “ Beeper value” operation Use and key to preset values.

For example:
Preset “Low limit” ( Low limit 10d ) e.g. Low limit = 20 kg 
EXCELL X
Series Weighing Scale - icon 40

Preset “High limit” ( High limit  Low limit ) e.g. High limit = 25 kg
EXCELL X Series Weighing Scale - icon 41

Preset “Beeper value” ( Refer to Note ) e.g. Beeper value = 22EXCELL X
Series Weighing Scale - icon 42

 Preset Single point (preset low limit only):
After “preset low limit” procedures is completed and the display shows    then press key again, the display shows .
. This means that the “preset single point” procedure is completed.
NOTE

A Setting for the status that LCD is on and the beeper beep:
0 = when stable, the beeper beeps and LCD is on.
1 = when stable, the beeper beeps; whether stable or not, LCD is on.
2 = whether stable or not, the beeper beeps and LCD is on.
3 = open warning device: when the weight is higher than HI value and the weight is stable, LCD is on and Relay Card open.
B Setting for the beep status:
0 = No beep
1 = OK (when the weight is over Low Limit & under or equal to High Limit.), the beeper beeps.
2 = When the weight is under or equal to Low Limit & over High Limit, the beeper beeps.
Under Status in Preset Low Limit (preset single point only)
The BEEP, LCD mode should be fixed as follows:![EXCELL X Series Weighing Scale

  Warning device setting (not available in 4/5 key models)
Set HI value and value of the beep, LCD mode should be fixed as follows:

When the weight equals to HI value, Relay Card open and the weight is accumulated. Press CE key to dismiss the warning sound and the range of accumulated weight is [000.000]~[999999].
 Clear warning accumulation (not available in 4/5 key models)
 Press key first and then press key to clear all accumulated data.
 Accumulated data is cleared automatically under following conditions
a. when shift among weight mode, counting mode and warning accumulation mode.
b. when shift the units
c. turn off the scale
LCD indication:

◆ To exit preset mode, please press key.
2. Recall Check-weighing Values (not available in 4/5/10 key models)EXCELL
X Series Weighing Scale - fig.

3. Clearing Check-weighing Values (not available in 4/5/10 key models)
Press key then press key, and then press key CE Recall “Low limit
value”. Then press CE key again Clear “High limit value” and “Beeper value”
Press key then press key 6 times continuously Clear all values.
2-2-6 Totalizing (not available in 4/5 key models)

  1. Weight Totalizing
    Place goods on the platter, after stable and press key to save the weight value.
    Then the display shows the total number of additions and the totalized weight value.
    And the (M+) indication “▼” will flash on the display. The indicator will recover to show the weight value of the goods on the platter after 3 seconds and the (M+) indication “▼” is on.
    The indicator allows the next totalizing operation, even when the weight value does not return back to zero. The
    key is functional, when the weight value changes by more
    than 10d. The indicator will save the totalized weight value after the weight is stable.
    The indicator can totalize positive or negative weight but can’t do both at the same time.
    The totalized weight store must be reset to zero before it is possible to select positive or negative totalizing mode.
    The totalizing function can be used up to a maximum of 9999 times before it must be reset. The totalizing display is limited to 6 digits maximum.
    When totalizing, RS-232 will also output. ( Refer to F5 setting)

  2. Clear Totalized Weight Values (not available in 4/5 key models)
     Press then CE key to clear all totalized weight values.
     When changing between weighing and counting mode, or selecting weighing unit, the indicator will automatically clear all the totalized weight values.
     The indicators will automatically clear all the totalized weight values after turning on.

  3. Recall Totalized Weight Values (not available in 4/5 key models)
    Press key to display the total number of additions and the totalized weight value. And the (M+) indication “” will flash on the display. The indicator will return to the weighing mode after 3 seconds.
     The indicator will not display the negative sign “▼-” for negative totalized weight values  when recalling a totalized weight value, but when printing, the negative sign “-” will beprinted out (transmitted serially) for each negative weight and negative totalized weight.

2-3 Counting Function (not available in 4/5 key models)
2-3-1 Sampling

  1. Press key to select sample quantity from 10, 20, 50,100
  2. Select sample quantity and then place samples on the platter, and then press key, the display shows “   
  3.  After stable, the scale enters into counting mode and the display shows sample quantity.
    Sample Too Small
    Sample is less than 20 divisions. Sample is less than 20 divisions.
     Unit weight is less than 0.2 division. (0.1 d for Brazil regulation)
    When sampling, the above two symbols indications are on. Under such conditions, the scale can still work, but may result in lower count precision.
    When using 2-segment weighing mode, the above two symbol indications change to Range 2 and Range 1 and the two symbol indications are off.

2-3-2 Check Weighing
Refer to the operation of check weighing in weighing function.
2-3-3 Totalizing
Refer to the operation of totalizing in weighing function.

Chapter 3 General Function Setting

  • Switch on the scale. While the scale is counting down to zero, press and hold key until the display shows the software version number 02036. Release the key, the scale enters into the configuration setting mode and display F0.

EXCELL X Series Weighing Scale - icon 56

3-1 F4 Check Weighing Configurations EXCELL X Series Weighing Scale -
icon 57

3-2 F5 RS-232 Output Setting (Option)EXCELL X Series Weighing Scale -
icon 58

RS-232 Interface Format

  1. Mode: UART Signal of EIA-RS0232 C
    II . Format : 1. Baud rate : 1 200, 2 400, 4 800, 9 600 bits/second

  2. Data bits : 8 bits

  3. Parity bit : None

  4. Stop bits : 1 bit

  5. Code  : ASCII (Exchange code of American standard) EXCELL X Series Weighing Scale - icon 59

RS-232 Data Format
Command mode (r n P 0)

Command Function Return message definition
C T
    C
M T
    M
N S
M Z
    N
M Z
N Z
N S
R W
   
P T ,

number of digits
L| O| ,| 0| 0| 0| 1| 0| 0| | | Set low limit| N| N| | | non- numeric value
H| I| ,| 0| 0| 0| 1| 0| 0| | | Set high limit| N| G| | | over max weight
 | N| D| | | Increment d is incorrect

Stable transmission (r n P 1), Continuous (r n P 2), Press key to transmit (r n P 8) EXCELL X Series Weighing Scale - icon 60

HEAD1 ( 2 BYTES ) HEAD2 ( 2 BYTES )
OL    –     Overload , Under load TR    –     TARE Mode
ST    –     Display is Stable NT   –     NET Mode
US    –     Display is Unstable GS    –     GROSS Mode

DATA ( 7 or 8 BYTE )
2B ( HEX ) = “ + ” ( PLUS)
2D ( HEX ) = “ – ” ( MINUS )
2E ( HEX ) = “ . ” ( DECIMAL POINT )
UNIT ( 2、3 or 4 BYTE )
kg = 6B ( HEX ) ; 67 ( HEX )
lb = 6C( HEX ) ; 62 ( HEX )
tl.T = 74 ( HEX ) ; 6C ( HEX ) ; 2E ( HEX ) ; 54 ( HEX )
hkg = 68 ( HEX ) ; 67 ( HEX )
viss = 76 ( HEX ) ; 69 ( HEX ) ; 73 ( HEX ) ; 73 ( HEX )
Transmission examples: (r n P 2) RS-232 continuous transmissionEXCELL X
Series Weighing Scale - icon 61

Press key to transmit simple format (r n P 3)EXCELL X Series Weighing
Scale - icon 62

Press key to transmit complete format (r n P 4)
TICKETS NO. 0001
G 1.000kg
T 0.000kg
N 1.000kg
(3 blank lines)

TICKETS NO. 0002G 1.000kg
T 0.000kg
N 1.000kg
(3 blank lines)

TICKETS NO. 0003
G 1.000kg
T 0.000kg
N 1.000kg
(3 blank lines)

TOTAL NUMBER
OF TICKETS 0003
TOTAL
NET 3.000kg
(3 blank lines)

G = GROSS T = TARE N = NET
Stable Transmission in totalizing mode (r n P 5) EXCELL X Series
Weighing Scale - icon 67

Press key to transmit simple free format (r n P 6)
Same format as (r n P 3). Print the complete format for the first time. Then only print NET weight.
Please refer to F14 for details.
Press key to transmit complete free format (r n P 7) Same format as (r n P 4). Print the complete format all the time. Please refer to F14 for details.
RS232 output format in HOLD MODE
Please set (r n P 8) in F5. If there is only RS-232, press to print out the HOLD value on the display.

      1 . 0 0 0 k g

Print after Removing Goods (5% mode) (r n P 11)

Stage Condition(s) Action(s)
1: Goods placed and weighed on platter Weight has become stable. Weight >

zero point

Weight ≥ 20 weighing units

(i.e. 5% x Weight ≥ 1 weighing unit)

| Beeper   beeps  twice,   and printing data (stable weight

compliant with conditions on the left) is ready to be sent.

2: Just removed goods from platter| Instantaneous weight reading drops below 95% of last stable weight (stable weight of Stage 1)| Printing data of Stage 1 is sent to the printer (same printing formats as those of

(r n P 1).

Print after Removing Goods (OK mode) (r n P 12)

Stage Condition(s) Action(s)
1: Goods placed and weighed on platter Weight has become stable. Weight >

zero point

Check weighing OK status (within a predetermined weight range)

| Beeper beeps twice, and printing data (stable weight compliant with conditions on

the left) is ready to be sent.

2: Just removed

goods from platter

| Instantaneous weight reading drops

below 95% of last stable weight (stable weight of Stage 1).

| Printing data of Stage 1 is

sent to the printer (same printing formats as those of

(r n P 1).

Continuous transmission, bluetooth format (r n P 13)

HEAD1 ( 2 BYTES ) HEAD2 ( 2 BYTES )
OL    –     Overload , Under load N   –     TARE Mode
ST    –     Display is Stable G   –     NET Mode
US    –     Display is Unstable GS    –     GROSS Mode

DATA (8 BYTE )
2B ( HEX ) = “ + ” ( PLUS)
2D ( HEX ) = “ – ” ( MINUS )
2E ( HEX ) = “ . ” ( DECIMAL POINT )
UNIT (3 BYTE )
‘ ‘kg; ‘ ‘lb; tlT; hkg; vis

  1. The gross weight (+0.876 kg) shows as below, after stable: (no tare or pre-tare mode)EXCELL X Series Weighing Scale - icon 69 Stable transmission only weight value is transmitted (r n P 14)No +/-. If display is 1.000kg , transmit

F5

|

Function

| Press| key| Press| key|

Press           key twice after zeroing

---|---|---|---|---|---|---
r n p| 0| RS232 command mode| Once received read weight command, transmit weight in same format as r n p 1.
r n p| 1| Stable transmission| After return to zero, transmit next stable weight.
r n p| 2| Continuous transmission.| RS232 transmit continuously. Keypad has no effect.
r n p| 3| Press  key to transmit simple format| Transmit when weight change

±10d,

| Transmit when weight change

±10d,

| Print TOTAL and clears totalized

values

r n p| 4| Press    key to transmit complete format.| Transmit when weight change

±10d,

| Transmit when weight change

±10d,

| Print TOTAL and clears totalized values

r n p

|

5

| Stable transmission in totalizing mode (After return to zero, transmit next stable weight which

is > +10d)

|

No transmission

|

No transmission

| Print TOTAL and clears totalized values

r n p

|

6

| Press    key to transmit simple free format| Transmit when weight change

±10d,

| Transmit when weight change

±10d,

| Print TOTAL and clears totalized values

r n p

|

7

| Press     key to transmit complete free format| Transmit when weight change

±10d,

| Transmit when weight change

±10d,

| Print TOTAL and

clears totalized values

r n p

|

8

| Press           key to transmit same format as (r n P 1) and (r n

P 2)

|

No transmission

| Transmit as stable weight

±10d

| No transmission, totalized values not cleared

r n p

|

9

|

Continuous Transmission (Brazil)

|

Continuous transmission

|

Continuous transmission

| Continuous transmission, totalized values not

cleared

EXCELL PRECISION CO., LTD.

r n p 10

|  M+  or     key

Transmission (Brazil)

|

RS232 transmit

|

RS232 transmit

| Print TOTAL and

clears totalized values

---|---|---|---|---
r n p 11| Print after removing goods (5% mode)| After placing item and become stable, beep twice. RS232 transmit item weight after item is removed.
r n p 12| Print after removing goods (OK mode)| RS232 transmit only “OK” item weight after item is removed. No transmission while in “HI” or “LO”.
r n p 13| Continuous transmission, bluetooth format| Bluetooth transmit continuously through RS232. Keypad has no effect.
r n p 14| Stable transmission, only weight value is transmitted| After return to zero, transmit next stable weight’s weight value only.

3-3 F6 Exit Function
Use to select F6. Then press to count down to zero and exit the setting.
3-4 F7 Internal Value Display Mode
Use or to select F7. Then press to display internal value. Press   again will see F7.
3-5 F8 Weight Hold Mode Setting

 Before setup, please switch the SWA1 on MINI JUMPER to ADJ position
 After setup, please switch the SWA1 on MINI JUMPER back to LOCK position
  In hold mode, press key, to print the hold value as shown on display. (It’s not related to the settings of F5 transmission mode, but it needs to select the  proper Baud rate according to the transmission of the receiver.)
(To setup transmission rate, please refer to F5 RS-232 Interface Output Setting (option))
Use   key to select a value from hold 0 ~ hold 4 and then press key to complete setup.
hold 0 = No hold function
hold 1 = For varying weighing value, the scale will automatically hold the maximum weighing value to display. To exit hold mode, press any key (except the key).
hold 2 = After the scale is stabilized, the scale will automatically hold the display value( not changeable due to external variables)To exit hold mode, press any key.( except the key )
hold 3 = After the scale is stabilized, the scale will automatically hold the display value( not changeable due to external variables).After zero return ( or weight is less than 10d), the scale exits the hold mode automatically.
hold 4 = Animal Scale function. When animal is on the scale platter and is stable, the scale will automatically hold the display value (not changeable due to external variables). After the animal is off the scale platter, the scale exits the hold mode automatically.
Animal Scale Hold Setup (hold 4)EXCELL X Series Weighing Scale - icon
80

3-6 F11 ID Code Setting
(must be used with r n P 1, r n P 2, r n P 8 of F5)EXCELL X Series Weighing
Scale - icon 81

RS232 DATA FORMAT
Stable transmission (r n P 1), Continuous (r n P 2), Press key to transmit (r n P 8) EXCELL X Series Weighing Scale - icon 94

3-7 F12 Print Key ( ) Function SettingEXCELL X Series Weighing Scale -
icon 92

3-8 F14 Customized Header Setting (r n P 6, r n P 7)

CODE Description CODE Description
0 No print. 6 P/N
1 TICKET NO. 7 S/N
2 G 8 DATE (Note: need FB53’s MINI_PRINTER to print)
3 T 9 TIME (Note: need FB53’s MINI_PRINTER to print)
4 PT A PCS
5 N  

F14 contains a 9-digit code. For example: 6 1 2 3 4 5 0 0 0 ○1
F5 = r n P 6 Simple Free Format ○2
F5 = r n P 7 Complete Free Format

EXCELL X Series Weighing Scale - icon 96

After power-off, S/N will reset as 1. P/N will be saved in memory, available during next power-on.

Appendix 1 Option Card Description

RS232 Output
1. Weighing scale (AW, HW, FD, RW, TW)
RS232 card’s 6PIN cable connect to CN3 of mainboardEXCELL X Series Weighing
Scale - icon 86

Relay Output
Principle of Relay operation
Use checkweighing pre-set key (TW, AW) or though F4 from the menu (TW, AW, RW, HW) to get in checkweighing mode to set the HIGH and LOW limit points. Between HIGH and LOW limits are OK range.
If the weight is below LOW limit, the data will output in LOW port;
If the weight is between HIGH and LOW limits (OK range), the data will output in OK port;
If the weight is above HIGH limit, the data will output in HIGH port
 Please refer to the operation of Pre-set key and F4 function.

Weighing scale (AW, HW, FD, RW, TW)

  1. PIN definitionEXCELL X Series Weighing Scale - icon 87

  2. ConnectionEXCELL X Series Weighing Scale - icon 100

  3.  Power supply for Relay
    The power supply of the RELAY card is a dual power supply option (5V and 12V) supplied by the system itself. It can also use an external power supply. If so, please open circuit at JP1 and short circuit at JP2.
    The factory default is 5V power supply. To use 12V power supply, please short circuit J12.

  4.  Configuration
    OK, High, and Low can be set to NO (normally open, J2, J3, J5) or NC (normally closed, J1, J4, J6). The default value is NO (normally open, J2, J3, J5)
     OK, High, and Low are NO (normally open, J2, J3, J5)  defaultEXCELL X
Series Weighing Scale - icon 101 OK, High, and Low are NC (normally close, J1, J4, J6)
    Make J1, J4, J6 open circuit by cutting the circuit. Then make J2, J3, J5 short circuit with solder.EXCELL X Series Weighing Scale -
fig34Restore factory settings when RJ45 option card is installed
    If scale does not work properly after modifying setting through RJ45 card, please follow the steps below to restore to factory setting.
    In the weighing mode, hold the key while press key at the same time (within 1 second). Then release key, and “RELOAD” appears. When reloading end, please restart the scale to restore to the factory settings.

Appendix 2 Load Cell PIN

For indicators only

EXCELL X Series Weighing Scale - fig 63

Appendix 3 7-Segment Display CharactersEXCELL X Series Weighing Scale -
fig 52

V22. 1222 6F, No. 127, Lane 235, Baoqiao Rd., Xindian District, New Taipei City 23145, Taiwan