EXCELL X Series Weighing Scale User Manual
- June 13, 2024
- EXCELL
Table of Contents
- Preparing to Use the Scale
- Precautions for Use
- Safety Instructions for Lithium Batteries
- Chapter 1 Introduction
- Chapter 2 General Operation Description
- Chapter 3 General Function Setting
- Appendix 1 Option Card Description
- Appendix 2 Load Cell PIN
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
EXCELL PRECISION CO.,LTD.
X Series Weighing Scale
User Manual
02036XXX
ZSME300000422
© EXCELL PRECISION CO., LTD. All rights reserved worldwide.
The information contained herein is the property of EXCELL PRECISION CO., LTD.
and is supplied without liability for errors or omissions. No part may be
reproduced or used except as authorized by contract or other written
permission. The copyright and the foregoing restriction on reproduction and
use extend to all media in which the information may be embodied.
Check Firmware Version
Turn on scale and hold ZERO key during countdown. Display firmware version
02036.
Turn off scale and turn on scale and hold TARE key during countdown. Display
maintenance number XXX, which is ranged from 0~999. Turn off and turn on scale
to return to weighing mode.
Thank for your purchasing of our EXCELL Weighing Scale. To guide you to use
our product correctly, please read this User Manual carefully to extend the
life of machine and to avoid error.
Preparing to Use the Scale
-
Locate the scale on a firm level surface free from vibrations for accurate weight readings.
Adjust the four leveling feet to centre the leveling bubble on the scale. -
Avoid hot sunshine directly on the scale or near the exhaust port of ventilating system.
-
Please use a separate power source plug to avoid the disturbance of other electric appliances.
-
There should be no weight on the scale when power is turned on.
-
Commodity should be placed at the centre of platter when being weighed, and its size should not exceed the dimension of the platter.
-
Please warm the scale 15 ~ 20 minutes before using.
-
Please note that when symbol appears on the screen, the scale needs to be charged.
-
Any suggestion is warmly welcome.
Precautions for Use
- Please operate or charge the scale in an open area. Do not squeeze the power cord to avoid wire on fire.
- Please keep scale in a cool and dry place. Do not store under high temperatures.
- Please keep the scale clean and free from insect infestation.
- Avoid impacting with other items or overloaded with excessively heavy weights (The load must not exceed the maximum capacity of the scale).
- If the scale is not going to be used for some time, please clean it and store it in a plastic bag in dry condition. A desiccant sachet may be included to prevent moisture from building up.
- Operating temperature: -10℃ ~ + 40℃
- It is recommended to be used indoors and in environments with a height of less than 2000m
- If the product is used in a manner not specified by the manufacturer, product warranty may be limited.
Safety Instructions for Lithium Batteries
-
Please pay attention to the storage temperature of the product. Do not place it in a high temperature environment. The ambient temperature should be less than 50C.
-
After installing the battery, if no display when power is turned on, please check whether the battery polarity is reversed. The polarity must be installed correctly to avoid battery power wasted away.
-
When the LED flashes in the charging state, it means there are the following abnormal states, please check:
a) Battery is installed but the contact is poor, please check whether the battery is installed properly.
b) Please check whether the polarity of the battery is reversed. When the polarity is reversed, the LED will flash after charging for a period of time.
c) When battery is removed and the AC power cord is still plugged in, the LED will also flash.
When plugged in without the battery installed, there will be a slight frequency conversion sound, which is normal and does not affect the use of the function. -
When symbol appears, scale needs to be charged.
a) When charging, the red LED will light up. Please refer to 1-4 for estimated charging hours.
b) When the battery is fully charged, blue LED will light up.
c) If scale is fully charged, after plugging in, the blue light will turn on after about 5~10 minutes of voltage detection. The LED charging indicator is to indicate the status of the charging process and whether the charging is working properly. To check the battery level, please unplug the AC cable first and turn on scale, and then check the battery symbol displayed in the lower left corner of the display. The number of bars under the battery symbol indicates battery level. 0 bar means <= 10% when the low power warning symbol ( ) flashes to indicate that scale needs to be charged. -
Please operate or charge the scale in an open area. Do not squeeze the power cord to avoid wire on fire. While charging, the temperature of battery should below 45℃.
-
Our product uses a single-cell cylindrical 18650-3.7V lithium-ion battery. Battery’s should be 3.6~3.7V and capacity is not restricted.
-
If the appearance of the battery is deformed, damaged, etc., please do not install it for the safety of use.
Chapter 1 Introduction
1-1 Production Introduction
-
High performance A/D converter
0.3 uv/D high sensitivity
zero point adjustable range -2mV~ +5mV
Sampling speed 10 times/second use range -4mV ~ +30mV
non-linear scale 0.01% full scale
load cell stimulate power source 5V DC ±2% 100mA -
According to different resolution to do linearity calibration
Ordinary resolution models (below 10000)
Do specification calibration first then do weight calibration
High resolution models (10000~30000)
Do linearity calibration first specification calibration weight calibration at last LCD display with LED backlight, powered by battery or plug-in mains, automatic power-off function to ensure the stability of the scale. When battery voltage is lower than the system voltage, scale is automatically powered off to ensure the accuracy and stability of the scale. -
Check Weighing function for high limit and low limit and OK range.
-
4 HOLD functions including animal scale HOLD
-
Depending on actual space, a RS232 card and/or a relay card can be installed.
1-2 Display Description
HI | : | High limit value |
---|---|---|
OK | : | OK range within HI and LO limits |
LO | : | Low limit value |
kg | : | “kg” unit |
lb | : | “lb” unit |
Pcs | : | Counting mode |
% | : | Percent indication |
→O← | : | “Zero” indication |
Net | : | “Net weight” |
indication
| :| “Low battery
power” indication
▼1 | “Stable” indication | |
---|---|---|
▼2 | : | “Pre-tare mode” indication |
▼3 | : | (M+) “Accumulation mode” indication |
▼5 | : | ( **** ) “Samples insufficient” indication |
▼6 | : | ( ) “Unit weight insufficient” indication |
▼7 | : | “Viss” unit (Burma unit) |
For Dual Range Models, the indicator 5 and 6 will be defined as below:
▼6 is Range 1 ▼5 is Range 2
1-3 Keypad Functions Description
Key description| 4/5 key| 10 key| 12 key| Other
variation
---|---|---|---|---
Net/Gross key| | | | NET/GROSS
Loop select from the preset units|
UNITS
| UNITS| UNITS| lb/kg
Preset weight and quantity for weight check or quantity check| | | | TGT SET
Accumulate weight or quantity| | +| M+|
Tare to deduct the container weight| | | | TARE
Set preset tare| | | |
Recall the totalization value, preset value and pre-tare value| | | | RE-CALL
Clear the totalization value, preset value and pre-tare value.| | CE|
CE|
Zero the scale.| | | | ZERO
Press this key to input the numbers (0 ~ 9) and to light up the backlight.| |
| |
Press this key to print the total data and to confirm| | | | PRINT
Go into counting mode.| | | |
COUNT or Q’TY SET
Press this key to sample.| | | | SMPL
key and key are not available for 10-key models.
1-4 Power Description
Power | Battery | 18650 3.7V lithium battery |
---|---|---|
Plugged in | 100~240V AC | |
Power consumption varies depending 0~100% backlight used (mA) | No backlight |
75% backlight (factory default)
≈ 24| ≈ 28
Scale has a built-in power saving function to extend usage time. Table below shows the battery capacity and estimated usage time. Time may vary with different brands of lithium batteries and are for reference only.
Battery capacity | 2000mA | 2500mA | 3000mA | 3200mA | 3500mA |
---|---|---|---|---|---|
Average usage time | 80~90 |
hours
| 95~105
hours
| 110~120
hours
| 120~130
hours
| 130~140
hours
Estimated charging time| ≈2.5 hours| ≈3 hours| ≈3.5 hours| ≈4 hours| ≈4.5
hours
Assume 25% in use for average usage time. If use continuously, time will be
reduced by ~40%.
Low Power Alarm
When symbol flashes, scale needs to be charged. To check the battery level,
please unplug the AC cable first, and check the battery symbol displayed in
the lower left corner of the display. The number of bars under the battery
symbol indicates battery level. 4 bars mean 100%, 3 bars mean 75%, 2 bars mean
50%, 1 bar means 25%, and 0 bar means <= 10% when the low power warning symbol
( ) flashes to indicate that scale needs to be charged. If not charge
immediately, scale auto shuts down within 5~10 hours or 1~2 hours with
backlight. The cut voltage is about 3.5V. Once it auto shuts down and enters
the battery protection mode, it must be charged before it can be used again.
Please recharge at once when the symbol shows in order to keep the weight
accuracy.
Charging indicator a) When charging, the red LED will light up. Please refer
to 1-4 for estimated charging hours.
b) When the battery is fully charged, blue LED will light up.
c) If scale is fully charged, after plugging in, the blue light will turn on
after about 5~10 minutes of voltage detection. The LED charging indicator is
to indicate the status of the charging process and whether the charging is
working properly. To check the battery level, please unplug the AC cable first
and turn on scale, and then check the number of bars under battery symbol for
battery level.
1-5 Error Messages
oL Weight exceeds 9d of maximum capacity. (d=division)
E1 Zero value after power on is over +10% FS.
E2 Zero value after power on is less than -10% FS.
need to set C5 to 1 to have E1 and E2 warnings
E4 Unstable zero return, unstable over 10 sec. Press
to leave E4.
E6 Zero is too high when calibrating. (over internal value 350,000)
E7 Zero is too low when calibrating. (under internal value 80,000)
E8 Resolution is set higher than factory setting. Send it back to us to unlock
to set new resolution.
E10 The scale is not in level status.(only available with level detector
equipment.)
– – – – – – For weight < -20d without tare or pretare device in operation.
OIML approval models need to set C5 to 1 to show “- – – – – -“
E10 Level Switch (option)
Make PCB J3 open circuit and connect signal to CN7 of PCB. Display shows E10
after 2 seconds and all keys stop working in the mean time. If you do not need
level switch, make J3 short circuit.
Chapter 2 General Operation Description
2-1 Backlight Function
Press key to loop select the display backlight mode: Auto 1~4, bL. on, bL.
oFF.
Auto 1~4 “Auto Backlight” mode. When the weight is over 10d or any key is
pressed, the backlight will be switched on. When the weight returns to zero
(the weight on platform is less than 10d), the display backlight will switch
off after 10 seconds.
1~4 (25%~100% backlight) is the brightness selection. Default is 3 (75%).
bL. On Display backlight is on all the time.
bL. oFF Display backlight is off.
2-2 Weighing Mode
2-2-1 Units Selection (not available in 4 key model)
- After indicator is turned on, use UNITS key to select a unit from kg, lb, tael or viss, as the screen indicated.
- The selected unit will be memorized when you turn the indicator off. And the memorized unit will appear after you turn on the indicator next time.
2-2-2 Zero Function
Press key to re-zero the display with no load on the platter. When zero is
set, the ( ) symbol will be displayed.
2-2-3 Tare Function
-
When the weight of the container is unknown ( )
1. Place the container on the platter, after stable and press key, the weight value returns to zero and net indication (Not ) is on.
2. Place goods into the container, then the indicator shows the net weight of goods.
3. Clear tare value
When removing the container and goods, the display shows the negative weight value of the container. Then press key to clear tare value. The indicator returns to zero and net indication ( Not ) is on.
4. Recall tare value Press then key the display shows tare value
Multiple tare operation Users can continuously increase or decrease the tare value by pressing the key.
The total tare value (tare value + pre-set tare value) can equal the full capacity of the indicator. -
When the weight of the container is known ( )
1. Press key and the display shows Use and keys to input weight value of the container. After finishing the procedures, the net indication (Not ) and pretare indication “” is on.
2. Place goods into the container, then the indicator shows the net weight of goods.
3. Clear pretare value Press then key, and then press CE key to clear pretare value.
When indicator returns to zero, net indication (Not ) and pretare indication “”▼ are off.
4. Recall pretare value Press then key the display shows pretare value
In Tare mode, the Preset tare function is disabled.
The indicators with two weighing ranges can NOT pre-set the tare value larger
than the first weighing range. For example: a 30 kg indicator is set by two
weighing ranges. The first range is 0 to 15 kg, and the second range is 15 to
30 kg. The pre-set tare value can not be larger than 15 kg.
2-2-4 Net/Gross Function (only available in 4/5 key models)
In Tare mode, press key once to display gross value. Net symbol “▼”disappears,
and the gross value “▼” appears. Press key again, it displays net value, net
symbol “▼” appears and gross symbol “▼” disappears. Press key continually to
display net value or gross value. In tare mode, key is able to work. When it
displays “▼”, all keys are disable except .
2-2-5 Check Weighing Mode (4/5 key models need to set through F4)
- Preset “ High limit”, “Low limit” and “ Beeper value” operation Use and key to preset values.
For example:
Preset “Low limit” ( Low limit 10d ) e.g. Low limit = 20 kg
Preset “High limit” ( High limit Low limit ) e.g. High limit = 25 kg
Preset “Beeper value” ( Refer to Note ) e.g. Beeper value = 22
Preset Single point (preset low limit only):
After “preset low limit” procedures is completed and the display shows then
press key again, the display shows .
. This means that the “preset single point” procedure is completed.
NOTE
A Setting for the status that LCD is on and the beeper beep:
0 = when stable, the beeper beeps and LCD is on.
1 = when stable, the beeper beeps; whether stable or not, LCD is on.
2 = whether stable or not, the beeper beeps and LCD is on.
3 = open warning device: when the weight is higher than HI value and the
weight is stable, LCD is on and Relay Card open.
B Setting for the beep status:
0 = No beep
1 = OK (when the weight is over Low Limit & under or equal to High Limit.),
the beeper beeps.
2 = When the weight is under or equal to Low Limit & over High Limit, the
beeper beeps.
Under Status in Preset Low Limit (preset single point only)
The BEEP, LCD mode should be fixed as follows:![EXCELL X Series Weighing Scale
- icon 47](https://manuals.plus/wp-content/uploads/2023/08/EXCELL-X-Series- Weighing-Scale-icon-47.jpg)
Warning device setting (not available in 4/5 key models)
Set HI value and value of the beep, LCD mode should be fixed as follows:
When the weight equals to HI value, Relay Card open and the weight is
accumulated. Press CE key to dismiss the warning sound and the range of
accumulated weight is [000.000]~[999999].
Clear warning accumulation (not available in 4/5 key models)
Press key first and then press key to clear all accumulated data.
Accumulated data is cleared automatically under following conditions
a. when shift among weight mode, counting mode and warning accumulation mode.
b. when shift the units
c. turn off the scale
LCD indication:
◆ To exit preset mode, please press key.
2. Recall Check-weighing Values (not available in 4/5/10 key models)
3. Clearing Check-weighing Values (not available in 4/5/10 key models)
Press key then press key, and then press key CE Recall “Low limit
value”. Then press CE key again Clear “High limit value” and “Beeper value”
Press key then press key 6 times continuously Clear all values.
2-2-6 Totalizing (not available in 4/5 key models)
-
Weight Totalizing
Place goods on the platter, after stable and press key to save the weight value.
Then the display shows the total number of additions and the totalized weight value.
And the (M+) indication “▼” will flash on the display. The indicator will recover to show the weight value of the goods on the platter after 3 seconds and the (M+) indication “▼” is on.
The indicator allows the next totalizing operation, even when the weight value does not return back to zero. The
key is functional, when the weight value changes by more
than 10d. The indicator will save the totalized weight value after the weight is stable.
The indicator can totalize positive or negative weight but can’t do both at the same time.
The totalized weight store must be reset to zero before it is possible to select positive or negative totalizing mode.
The totalizing function can be used up to a maximum of 9999 times before it must be reset. The totalizing display is limited to 6 digits maximum.
When totalizing, RS-232 will also output. ( Refer to F5 setting) -
Clear Totalized Weight Values (not available in 4/5 key models)
Press then CE key to clear all totalized weight values.
When changing between weighing and counting mode, or selecting weighing unit, the indicator will automatically clear all the totalized weight values.
The indicators will automatically clear all the totalized weight values after turning on. -
Recall Totalized Weight Values (not available in 4/5 key models)
Press key to display the total number of additions and the totalized weight value. And the (M+) indication “” will flash on the display. The indicator will return to the weighing mode after 3 seconds.
The indicator will not display the negative sign “▼-” for negative totalized weight values when recalling a totalized weight value, but when printing, the negative sign “-” will beprinted out (transmitted serially) for each negative weight and negative totalized weight.
2-3 Counting Function (not available in 4/5 key models)
2-3-1 Sampling
- Press key to select sample quantity from 10, 20, 50,100
- Select sample quantity and then place samples on the platter, and then press key, the display shows “
- After stable, the scale enters into counting mode and the display shows sample quantity.
Sample Too Small
Sample is less than 20 divisions. Sample is less than 20 divisions.
Unit weight is less than 0.2 division. (0.1 d for Brazil regulation)
When sampling, the above two symbols indications are on. Under such conditions, the scale can still work, but may result in lower count precision.
When using 2-segment weighing mode, the above two symbol indications change to Range 2 and Range 1 and the two symbol indications are off.
2-3-2 Check Weighing
Refer to the operation of check weighing in weighing function.
2-3-3 Totalizing
Refer to the operation of totalizing in weighing function.
Chapter 3 General Function Setting
- Switch on the scale. While the scale is counting down to zero, press and hold key until the display shows the software version number 02036. Release the key, the scale enters into the configuration setting mode and display F0.
3-1 F4 Check Weighing Configurations
3-2 F5 RS-232 Output Setting (Option)
RS-232 Interface Format
-
Mode: UART Signal of EIA-RS0232 C
II . Format : 1. Baud rate : 1 200, 2 400, 4 800, 9 600 bits/second -
Data bits : 8 bits
-
Parity bit : None
-
Stop bits : 1 bit
-
Code : ASCII (Exchange code of American standard)
RS-232 Data Format
Command mode (r n P 0)
Command | Function | Return message definition |
---|---|---|
C | T | |
C | ||
M | T | |
M | ||
N | S | |
M | Z | |
N | ||
M | Z | |
N | Z | |
N | S | |
R | W | |
P | T | , |
number of digits
L| O| ,| 0| 0| 0| 1| 0| 0|
H| I| ,| 0| 0| 0| 1| 0| 0|
| N| D|
Stable transmission (r n P 1), Continuous (r n P 2), Press key to transmit (r n P 8)
HEAD1 ( 2 BYTES ) | HEAD2 ( 2 BYTES ) |
---|---|
OL – Overload , Under load | TR – TARE Mode |
ST – Display is Stable | NT – NET Mode |
US – Display is Unstable | GS – GROSS Mode |
DATA ( 7 or 8 BYTE )
2B ( HEX ) = “ + ” ( PLUS)
2D ( HEX ) = “ – ” ( MINUS )
2E ( HEX ) = “ . ” ( DECIMAL POINT )
UNIT ( 2、3 or 4 BYTE )
kg = 6B ( HEX ) ; 67 ( HEX )
lb = 6C( HEX ) ; 62 ( HEX )
tl.T = 74 ( HEX ) ; 6C ( HEX ) ; 2E ( HEX ) ; 54 ( HEX )
hkg = 68 ( HEX ) ; 67 ( HEX )
viss = 76 ( HEX ) ; 69 ( HEX ) ; 73 ( HEX ) ; 73 ( HEX )
Transmission examples: (r n P 2) RS-232 continuous transmission
Press key to transmit simple format (r n P 3)
Press key to transmit complete format (r n P 4)
TICKETS NO. 0001
G 1.000kg
T 0.000kg
N 1.000kg
(3 blank lines)
TICKETS NO. 0002G 1.000kg
T 0.000kg
N 1.000kg
(3 blank lines)
TICKETS NO. 0003
G 1.000kg
T 0.000kg
N 1.000kg
(3 blank lines)
TOTAL NUMBER
OF TICKETS 0003
TOTAL
NET 3.000kg
(3 blank lines)
G = GROSS T = TARE N = NET
Stable Transmission in totalizing mode (r n P 5)
Press key to transmit simple free format (r n P 6)
Same format as (r n P 3). Print the complete format for the first time. Then
only print NET weight.
Please refer to F14 for details.
Press key to transmit complete free format (r n P 7) Same format as (r n P 4).
Print the complete format all the time. Please refer to F14 for details.
RS232 output format in HOLD MODE
Please set (r n P 8) in F5. If there is only RS-232, press to print out the
HOLD value on the display.
1 | . | 0 | 0 | 0 | k | g |
---|
Print after Removing Goods (5% mode) (r n P 11)
Stage | Condition(s) | Action(s) |
---|---|---|
1: Goods placed and weighed on platter | Weight has become stable. Weight > |
zero point
Weight ≥ 20 weighing units
(i.e. 5% x Weight ≥ 1 weighing unit)
| Beeper beeps twice, and printing data (stable weight
compliant with conditions on the left) is ready to be sent.
2: Just removed goods from platter| Instantaneous weight reading drops below 95% of last stable weight (stable weight of Stage 1)| Printing data of Stage 1 is sent to the printer (same printing formats as those of
(r n P 1).
Print after Removing Goods (OK mode) (r n P 12)
Stage | Condition(s) | Action(s) |
---|---|---|
1: Goods placed and weighed on platter | Weight has become stable. Weight > |
zero point
Check weighing OK status (within a predetermined weight range)
| Beeper beeps twice, and printing data (stable weight compliant with conditions on
the left) is ready to be sent.
2: Just removed
goods from platter
| Instantaneous weight reading drops
below 95% of last stable weight (stable weight of Stage 1).
| Printing data of Stage 1 is
sent to the printer (same printing formats as those of
(r n P 1).
Continuous transmission, bluetooth format (r n P 13)
HEAD1 ( 2 BYTES ) | HEAD2 ( 2 BYTES ) |
---|---|
OL – Overload , Under load | N – TARE Mode |
ST – Display is Stable | G – NET Mode |
US – Display is Unstable | GS – GROSS Mode |
DATA (8 BYTE )
2B ( HEX ) = “ + ” ( PLUS)
2D ( HEX ) = “ – ” ( MINUS )
2E ( HEX ) = “ . ” ( DECIMAL POINT )
UNIT (3 BYTE )
‘ ‘kg; ‘ ‘lb; tlT; hkg; vis
- The gross weight (+0.876 kg) shows as below, after stable: (no tare or pre-tare mode) Stable transmission only weight value is transmitted (r n P 14)No +/-. If display is 1.000kg , transmit
F5
|
Function
| Press| key| Press| key|
Press key twice after zeroing
---|---|---|---|---|---|---
r n p| 0| RS232 command mode| Once received read weight command,
transmit weight in same format as r n p 1.
r n p| 1| Stable transmission| After return to zero, transmit next
stable weight.
r n p| 2| Continuous transmission.| RS232 transmit continuously.
Keypad has no effect.
r n p| 3| Press key to transmit simple format| Transmit when
weight change
±10d,
| Transmit when weight change
±10d,
| Print TOTAL and clears totalized
values
r n p| 4| Press key to transmit complete format.| Transmit when weight change
±10d,
| Transmit when weight change
±10d,
| Print TOTAL and clears totalized values
r n p
|
5
| Stable transmission in totalizing mode (After return to zero, transmit next stable weight which
is > +10d)
|
No transmission
|
No transmission
| Print TOTAL and clears totalized values
r n p
|
6
| Press key to transmit simple free format| Transmit when weight change
±10d,
| Transmit when weight change
±10d,
| Print TOTAL and clears totalized values
r n p
|
7
| Press key to transmit complete free format| Transmit when weight change
±10d,
| Transmit when weight change
±10d,
| Print TOTAL and
clears totalized values
r n p
|
8
| Press key to transmit same format as (r n P 1) and (r n
P 2)
|
No transmission
| Transmit as stable weight
±10d
| No transmission, totalized values not cleared
r n p
|
9
|
Continuous Transmission (Brazil)
|
Continuous transmission
|
Continuous transmission
| Continuous transmission, totalized values not
cleared
EXCELL PRECISION CO., LTD.
r n p 10
| M+ or key
Transmission (Brazil)
|
RS232 transmit
|
RS232 transmit
| Print TOTAL and
clears totalized values
---|---|---|---|---
r n p 11| Print after removing goods (5% mode)| After placing item and
become stable, beep twice. RS232 transmit item weight after item is removed.
r n p 12| Print after removing goods (OK mode)| RS232 transmit only “OK”
item weight after item is removed. No transmission while in “HI” or “LO”.
r n p 13| Continuous transmission, bluetooth format| Bluetooth transmit
continuously through RS232. Keypad has no effect.
r n p 14| Stable transmission, only weight value is transmitted| After
return to zero, transmit next stable weight’s weight value only.
3-3 F6 Exit Function
Use to select F6. Then press to count down to zero and exit the setting.
3-4 F7 Internal Value Display Mode
Use or to select F7. Then press to display internal value. Press again will
see F7.
3-5 F8 Weight Hold Mode Setting
Before setup, please switch the SWA1 on MINI JUMPER to ADJ position
After setup, please switch the SWA1 on MINI JUMPER back to LOCK position
In hold mode, press key, to print the hold value as shown on display. (It’s
not related to the settings of F5 transmission mode, but it needs to select
the proper Baud rate according to the transmission of the receiver.)
(To setup transmission rate, please refer to F5 RS-232 Interface Output
Setting (option))
Use key to select a value from hold 0 ~ hold 4 and then press key to
complete setup.
hold 0 = No hold function
hold 1 = For varying weighing value, the scale will automatically hold the
maximum weighing value to display. To exit hold mode, press any key (except
the key).
hold 2 = After the scale is stabilized, the scale will automatically hold the
display value( not changeable due to external variables)To exit hold mode,
press any key.( except the key )
hold 3 = After the scale is stabilized, the scale will automatically hold the
display value( not changeable due to external variables).After zero return (
or weight is less than 10d), the scale exits the hold mode automatically.
hold 4 = Animal Scale function. When animal is on the scale platter and is
stable, the scale will automatically hold the display value (not changeable
due to external variables). After the animal is off the scale platter, the
scale exits the hold mode automatically.
Animal Scale Hold Setup (hold 4)
3-6 F11 ID Code Setting
(must be used with r n P 1, r n P 2, r n P 8 of F5)
RS232 DATA FORMAT
Stable transmission (r n P 1), Continuous (r n P 2), Press key to transmit (r
n P 8)
3-7 F12 Print Key ( ) Function Setting
3-8 F14 Customized Header Setting (r n P 6, r n P 7)
CODE | Description | CODE | Description |
---|---|---|---|
0 | No print. | 6 | P/N |
1 | TICKET NO. | 7 | S/N |
2 | G | 8 | DATE (Note: need FB53’s MINI_PRINTER to print) |
3 | T | 9 | TIME (Note: need FB53’s MINI_PRINTER to print) |
4 | PT | A | PCS |
5 | N |
F14 contains a 9-digit code. For example: 6 1 2 3 4 5 0 0 0 ○1
F5 = r n P 6 Simple Free Format ○2
F5 = r n P 7 Complete Free Format
After power-off, S/N will reset as 1. P/N will be saved in memory, available during next power-on.
Appendix 1 Option Card Description
RS232 Output
1. Weighing scale (AW, HW, FD, RW, TW)
RS232 card’s 6PIN cable connect to CN3 of mainboard
Relay Output
Principle of Relay operation
Use checkweighing pre-set key (TW, AW) or though F4 from the menu (TW, AW, RW,
HW) to get in checkweighing mode to set the HIGH and LOW limit points. Between
HIGH and LOW limits are OK range.
If the weight is below LOW limit, the data will output in LOW port;
If the weight is between HIGH and LOW limits (OK range), the data will output
in OK port;
If the weight is above HIGH limit, the data will output in HIGH port
Please refer to the operation of Pre-set key and F4 function.
Weighing scale (AW, HW, FD, RW, TW)
-
PIN definition
-
Connection
-
Power supply for Relay
The power supply of the RELAY card is a dual power supply option (5V and 12V) supplied by the system itself. It can also use an external power supply. If so, please open circuit at JP1 and short circuit at JP2.
The factory default is 5V power supply. To use 12V power supply, please short circuit J12. -
Configuration
OK, High, and Low can be set to NO (normally open, J2, J3, J5) or NC (normally closed, J1, J4, J6). The default value is NO (normally open, J2, J3, J5)
OK, High, and Low are NO (normally open, J2, J3, J5) default OK, High, and Low are NC (normally close, J1, J4, J6)
Make J1, J4, J6 open circuit by cutting the circuit. Then make J2, J3, J5 short circuit with solder.Restore factory settings when RJ45 option card is installed
If scale does not work properly after modifying setting through RJ45 card, please follow the steps below to restore to factory setting.
In the weighing mode, hold the key while press key at the same time (within 1 second). Then release key, and “RELOAD” appears. When reloading end, please restart the scale to restore to the factory settings.
Appendix 2 Load Cell PIN
For indicators only
Appendix 3 7-Segment Display Characters
V22. 1222 6F, No. 127, Lane 235, Baoqiao Rd., Xindian District, New Taipei
City 23145, Taiwan
pm-all@Wexcell.conn.tw
+886-2-8919-1000
https://www.excell-scale.com
+886-2-8919-2209
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>