EVOLVE E2SC LED Roadway Security Light Instruction Manual
- June 13, 2024
- EVOLVE
Table of Contents
- Construction
- Optical System
- Electrical
- Surge Protection*
- Lumen Maintenance
- Ambient Temperature Factor
- Ratings
- Controls
- Ordering Information
- Photometric Plots
- House Side Shield – E2SC/ERLC
- Street Side Shield – E2SC/ERLC
- Side Shield (L & R) – E2SC/ERLC
- Mounting
- Effective Projected Area
- Weight
- Accessories
- Networked Lighting Control
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Instruction Manual
CUSTOMER NAME ____
PROJECT NAME __
DATE __
TYPE __
CATALOG NUMBER ___
E2SC Security Light
LED Roadway Lighting
The Evolve ® LED Security Light provides energy efficiency in a rugged, easy to install, light weight fixture. Current’s advanced optical design offers Type III and Type V photometry with the versatility of a field installable refractor option to meet your lighting requirements.
Construction
Housing: | Aluminum die cast enclosure |
---|---|
Lens: | Impact resistant tempered glass (non refractor version) |
Weight: | 8.5 lbs (3.8 kgs) without mounting bracket |
Optical System
Lumens: | 3,730 – 6,270 lm |
---|---|
Distribution: | Type III/IV and Type V |
Efficacy: | 100-128 LPW |
CCT: | 2700K, 3000K, 4000K, 5000K |
CRI: | ≥70 |
Electrical
Input Voltage: | 120-277V (no 347-480V) |
---|---|
Input Frequency: | 50/60Hz |
Power Factor: | ≥ 90 at rated watts |
Total Harmonic Distortion: | ≤ 20% at rated watts |
Surge Protection*
STANDARD | OPTIONAL |
---|---|
6kV/3kA | Enhanced 10kV/5kA (R Option) |
*Per ANSI C136.2-2018
WARRANTY
5 Year (Standard)
Lumen Maintenance
Projected Lxx per IES TM-21 at 25°C
LXX(10K) @ HOURS
LUMEN
CODES| LUMEN
CODES| 25,000 HR| 50,000 HR| 60,000 HR
---|---|---|---|---
04| C4| L95| L93| L92
05| C4| L93| L88| L86
06| C4| L83| L70| L65
04| V4| L95| L92| L90
05| V4| L94| L90| L89
06| V4| L91| L85| L83
Note: Projected Lxx based on LM80 (≥ 10,000 hour testing). Accepted Industry tolerances apply to initial luminous flux and lumen maintenance measurements.
Ambient Temperature Factor
AMBIENT
TEMP (°C)| INITIAL FLUX
FACTOR
---|---
10| 1.02
20| 1.01
25| 1
30| 0.99
40| 0.98
Ratings
Operating Temperature: | -40°C to 40°C |
---|---|
Vibration: | 3G per ANSI C136.31-2010 |
LM-79: | Testing in accordance with IES Standards |
Controls
Dimming:| Standard – 0-10V
Optional = DALI (Option U)
---|---
Sensors:| Photo Electric Sensors (PE) available
LightGrid and Daintree Compatible
Ordering Information
1. See ISO Plot page for the typical C4 distribution – this optic is designed
to address a Roadway Photometric Application and is a Type III without the
refractor, and Type IV with a refractor.
2. For Mounting on Wood Pole
3. Compatible with LightGrid
For additional information on E2SC IES files, please refer to LED.com
Photometric Plots
House Side Shield – E2SC/ERLC
DESCRIPTION
ELSHS-ERLC-BLCK
ELSHS-ERLC-GRAY
*E2SC shields are designed for Flat Glass Versions only.
Street Side Shield – E2SC/ERLC
DESCRIPTION
ELSFS-ERLC-BLCK-10
ELSFS-ERLC-BLCK-15
ELSFS-ERLC-BLCK-20
*E2SC shields are designed for Flat Glass Versions only.
Side Shield (L & R) – E2SC/ERLC
DESCRIPTION
ELS-ERLC-LEFTRIGHTSIDEKIT-BLCK-10
ELSHS-ERLC-GRAY
Shipped as a kit – L & R can be used independently
*E2SC shields are designed for Flat Glass Versions only.
Mounting
- Suggested Mounting Height: 12-28 ft. (4-8 M)
- Adjustable for 1.25 to 2 in. nominal mounting pipe
- Integral diecast mounting pipe stop
- Slipfitter with +/- 5 degrees of leveling adjustment
Effective Projected Area
- 0.38 sq ft.
Weight
- Approximate net weight: 8.5 lbs (3.8 kgs) without mounting bracket.
- With 24 in. (610 mm) Mounting Bracket: 16 lbs (7.3 kgs)
Accessories
SAP NUMBER | PART NUMBER | DESCRIPTION |
---|---|---|
74907 | 35-962150-02 | 24 in. Mounting Arm |
Kit for Wood Poles
93122446| ESR-E2SC-A| Field Installable
Refractor Kit
Networked Lighting Control
Current’s LightGrid™ Outdoor Lighting Control System is designed for Street and Roadway Applications. It enables remote monitoring, control, and asset management of a single fixture or a group of fixtures through a web enabled Central Management System.
LED.com
© 2023 Current Lighting Solutions, LLC.
All rights reserved.
Information and specifications subject to change without notice. All values
are design or typical values when measured under laboratory conditions.
(Rev 05/02/23)
OLP3160_R04
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>