Shelly Qubino Z-Wave 1PM Relay 16A 1 channel ALREZWE_W_1PM Manual
- June 13, 2024
- Shelly
Table of Contents
- Shelly
- Shelly Qubino Z-Wave 1PM Relay 16A 1 channel
- SKU: ALREZWE_W_1PM
- Quickstart
- Important safety information
- What is Z-Wave?
- Product Description
- Prepare for Installation / Reset
- Installation
- Inclusion/Exclusion
- Product Usage
- Supported load types
- Quick trouble shooting
- Association – one device controls an other device
- Configuration Parameters
- Parameter 1: SW (SW1) Switch type
- Parameter 17: Restore state of O (O1) after power failure
- Parameter 19: O (O1) Auto OFF with timer
- Parameter 20: O (O1) Auto ON with timer
- Parameter 23: O (O1) contact type – NO/NC
- Parameter 25: Set timer units to s or ms for O (O1)
- Parameter 36: O (O1) Power report on change – percentage
- Parameter 39: Minimal time between reports (O) O1
- Parameter 91: Water Alarm
- Parameter 92: Smoke Alarm
- Parameter 93: CO Alarm
- Parameter 94: Heat Alarm
- Parameter 119: Reset Parameters to default
- Parameter 120: Factory Reset
- Technical Data
- Supported Command Classes
- Explanation of Z-Wave specific terms
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Shelly
Shelly Qubino Z-Wave 1PM Relay 16A 1 channel
SKU: ALREZWE_W_1PM
Quickstart
This is a
secure
On/Off Power Switch
for
Europe.
To run this device please connect it to your mains power supply.
1. With the gateway application scan the QR code on the Device label and add
the Security 2 (S2) Device Specific Key (DSK) to the Provisioning List in the
gateway.
2. Connect the Device to a power supply.
3. Check if the blue LED is blinking in Mode 1. If so, the Device is not
added to a Z-Waveâ„¢ network.
4. Adding will be initiated automatically within a few seconds after
connecting the Device to a power supply, and the Device will be added to a
Z-Waveâ„¢ network automatically.”
5. The blue LED will be blinking in Mode 2 during the adding process.
6. The load connected to O will be blinking 1s on/1s off/1s on/1s off if the
Device is successfully added to a Z-Waveâ„¢ network.
7. The green LED will be blinking in Mode 1 if the Device is successfully
added to a Z-Waveâ„¢ network.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in
this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any
loss or damage resulting from failure to comply with the instructions in this
manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal
instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart
Home. This
device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message ( two-
way
communication) and every mains powered node can act as a repeater for other
nodes
( meshed network ) in case the receiver is not in direct wireless range of
the
transmitter.
This device and every other certified Z-Wave device can be used together
with any other
certified Z-Wave device regardless of brand and origin as long as both are
suited for the
same frequency range.
If a device supports secure communication it will communicate with other
devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to
maintain
backward compatibility.
For more information about Z-Wave technology, devices, white papers etc.
please refer
to www.z-wave.info.
Product Description
The Wave 1PM (Device) is a single product that enables the control of the on/off function for one electrical device such as bulb, ceiling fan, IR heater. It measures power consumption of the connected device. The Device is compatible with push-buttons and switches.
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory
default
state. Please make sure to reset the device into factory default. You can do
this by
performing an Exclusion operation as described below in the manual. Every
Z-Wave
controller is able to perform this operation however it is recommended to use
the primary
controller of the previous network to make sure the very device is excluded
properly
from this network.
Reset to factory default
This device also allows to be reset without any involvement of a Z-Wave
controller. This
procedure should only be used when the primary controller is inoperable.
1. To enter the Setting mode, quickly press and hold the S button on the
Device until the LED turns Solid blue.
2. Press the S button multiple times until the LED turns Solid red.
3. Press and hold (> 2s) S button on the Device until the red LED starts
blinking in Mode 3. Releasing the S button will start the factory reset.
4. During factory reset, the LED will turn solid green for about 1s, then the
blue and red LED will start blinking in Mode 3 for approx. 2s.
5. The blue LED will be blinking in Mode 1 if the Factory reset is
successful.
Safety Warning for Mains Powered Devices
ATTENTION: only authorized technicians under consideration of the country-
specific
installation guidelines/norms may do works with mains power. Prior to the
assembly of
the product, the voltage network has to be switched off and ensured against
re-switching.
Installation
The Device can control a various type of loads (e.g., bulbs) in one electrical
circuit up to 3.5 kW / 240 V AC. It can be retrofitted into standard
electrical wall boxes, behind power sockets and light switches or other places
with limited space.
âš CAUTION! Danger of electrocution. Mounting/installation of the Device
to the power grid has to be performed with caution, by a qualified
electrician.
âš WARNING! Danger of electrocution. Every change in the connections has
to be done after ensuring there is no voltage present at the Device terminals.
âš CAUTION! Use the Device only with a power grid and appliances that
comply with all applicable regulations. A short circuit in the power grid or
any appliance connected to the Device may damage it.
âš CAUTION! Do not connect the Device to appliances exceeding the given
max. load!
âš CAUTION! Do not shorten the antenna.
âš RECOMMENDATION: Place the antenna as far away as possible from metal
elements as they can cause signal interference.
âš CAUTION! Connect the Device only in the way shown in these
instructions. Any other method could cause damage and/or injury.
âš CAUTION! Do not install the Device where it can get wet.
âš CAUTION! Do not use the Device if it has been damaged!
âš CAUTION! Do not attempt to service or repair the Device yourself!
âš RECOMMENDATION: Connect the Device using solid single-core wires with
increased insulation heat resistance not less than PVC T105″°C (221″°F).
âš CAUTION! Before starting the mounting/installation of the Device,
check that the breakers are turned off and there is no voltage on their
terminals. This can be done with a phase tester or multimeter. When you are
sure that there is no voltage, you can proceed to connecting the wires.
AC – Power
If you are using AC power supply connect the load to the O terminal of the
Device and the Neutral wire. Connect the Live wire to an L terminal of the
Device.
Connect the Neutral wire to a N terminal of the Device. Connect a switch or a
push-button to the Device SW terminal and any of the unused L terminals of the
Device.
DC – Power
If you are using DC power supply, connect the wires. Connect the load to the O
terminal of the Device and the + wire. Connect the GND wire to a terminal of
the Device.
Connect the + wire to a + terminal of the device. Connect the switch/push-
button to the SW and any of the unused terminals of the Device.
âš CAUTION! Use only one phase AC circuit. Do not use mixed AC and DC
circuits.
âš RECOMMENDATION: For inductive appliances that cause voltage spikes
during switching on/off, such as electrical motors, fans, vacuum cleaners and
similar ones, RC snubber (0.1 μF / 100 Ω / 1/2 W / 600 V AC) should be
connected parallel to the appliance.
âš CAUTION! Do not allow children to play with the push-buttons/switches
connected to the Device. Keep the devices for remote control of Shelly Qubino
(mobile phones, tablets, PCs) away from children. LEGEND
Device terminals:
• N : Neutral terminal
• L : Live terminal (110–240 V AC)
• SW : Switch/push-button input terminal (controlling O)
• O : Load circuit output terminal
• + : 24-30 V DC positive terminals
• Ʇ : 24-30 V DC ground terminals
Wires:
• N : Neutral wire
• L : Live wire (110-240 V AC)
• + : 24–30 V DC positive wire
• GND : 24–30 V DC ground wire ”
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The
device needs
to be added to an existing wireless network to communicate with the
devices of this network.
This process is called Inclusion.
Devices can also be removed from a network. This process is called
Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network.
This
controller is turned into exclusion respective inclusion mode. Inclusion and
Exclusion is
then performed doing a special manual action right on the device.
Inclusion
1. Connect the Device to a power supply.
2. Check if the blue LED is blinking in Mode 1. If so, the Device is not
added to a Z-Waveâ„¢ network.
3. Enable add/remove mode on the gateway.
4. To enter the setting mode, quickly press and hold the S button on the
Device until the LED turns Solid blue.
5. Quickly release and then press and hold (> 2 s) the S button on the Device
until the blue LED starts blinking in Mode 3. Releasing the S button will
start the LEARN MODE.
6. The blue LED will be blinking in Mode 2 during the adding process.
7. The load connected to O will be blinking 1s on/1s off/1s on/1s off if the
Device is successfully added to a Z-Waveâ„¢ network.
8. The green LED will be blinking in Mode 1 if the Device is successfully
added to a Z-Waveâ„¢ network.
Exclusion
1. Connect the Device to a power supply.
2. Check if the green LED is blinking in Mode 1. If so, the Device is added
to a Z-Waveâ„¢ network.
3. Enable add/remove mode on the gateway.
4. To enter the Setting mode, quickly press and hold the S button on the
Device until the LED turns Solid blue.”
5. Quickly release and then press and hold (> 2s) the S button on the Device
until the blue LED starts blinking in Mode 3. Releasing the S button will
start the LEARN MODE.
6. The blue LED will be blinking in Mode 2 during the removing process.
7. The load connected to O will be blinking 1s on/1s off/1s on/1s off if the
Device is successfully removed from a Z-Waveâ„¢ network.
8. The blue LED will be blinking in Mode 1 if the Device is successfully
removed from a Z-Waveâ„¢ network.
Product Usage
LED SIGNALIZATION
Addon interface
Supported load types
- Resistive (incandescent bulbs, heating devices)
- Capacitive (capacitor banks, electronic equipment, motor start capacitors)
- Inductive with RC Snubber (LED light drivers, transformers, fans, refrigerators, air-conditioners)
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
- Make sure a device is in factory reset state before including. In doubt exclude before include.
- If inclusion still fails, check if both devices use the same frequency.
- Remove all dead devices from associations. Otherwise you will see severe delays.
- Never use sleeping battery devices without a central controller.
- Dont poll FLIRS devices.
- Make sure to have enough mains powered device to benefit from the meshing
Association – one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one
device
controlling another device is called association. In order to control a
different
device, the controlling device needs to maintain a list of devices that will
receive
controlling commands. These lists are called association groups and they are
always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’
Command.
Association Groups:
Group NumberMaximum NodesDescription
1 | 9 | Lifeline |
---|---|---|
2 | 9 | Switch 1 – Basic ON/OFF |
3 | 9 | Switch 1 – Multilevel |
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock
further
enhanced features.
IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus
56.
In case of a two byte value the same logic applies: Values greater than 32768
may
needed to be given as negative values too.
Parameter 1: SW (SW1) Switch type
This parameter defines as what type the device should treat the switch
connected to the SW (SW1) terminal.
Size: 1 Byte, Default Value: 2
SettingDescription
0 | momentary switch |
---|---|
1 | toggle switch (contact closed – ON / contact opened – OFF) |
2 | toggle switch (device changes status when switch changes status) |
Parameter 17: Restore state of O (O1) after power failure
This parameter determines if on/off status is saved and restored for load
connected to O (O1) after power failure.
Size: 1 Byte, Default Value: 0
SettingDescription
0 | Device saves last on/off status and restores it after a power failure |
---|---|
1 | Device does not save on/off status and does not restore it after a power |
failure, it remains off
Parameter 19: O (O1) Auto OFF with timer
If Load O (O1) is ON, you can schedule it to turn OFF automatically after a
period of time defined in this parameter. The timer is reset to zero each time
the device receives an ON command, either remotely (from the Gateway or
associated device) or locally from the switch.
Size: 2 Byte, Default Value: 0
SettingDescription
0 | Auto OFF Disabled |
---|---|
1 – 32535 | 1 – 32535 seconds (or milliseconds – see Parameter no. 25. Auto |
OFF timer enabled for a given amount of seconds (or milliseconds) resolution 100ms
Parameter 20: O (O1) Auto ON with timer
If Load O (O1) is OFF, you can schedule it to turn ON automatically after a
period of time defined in this parameter. The timer is reset to zero each time
the device receives an OFF command, either remotely (from the Gateway or
associated device) or locally from the switch.
Size: 2 Byte, Default Value: 0
SettingDescription
0 | Auto ON Disabled |
---|---|
1 – 32535 | 1 – 32535 seconds (or milliseconds – see Parameter no. 25. Auto |
ON timer enabled for a given amount of seconds (or milliseconds) resolution 100ms
Parameter 23: O (O1) contact type – NO/NC
Set value determines the type of Relay contact type for O (O1) output. The
Relay contact type can be normally open (NO) or normally closed (NC).
Size: 1 Byte, Default Value: 0
SettingDescription
0 | NO |
---|---|
1 | NC |
Parameter 25: Set timer units to s or ms for O (O1)
Set Timer Units to Seconds or Milliseconds Choose if you want to set the
timer in seconds or milliseconds in Parameters No. 19, 20.
Size: 1 Byte, Default Value: 0
SettingDescription
0 | timer set in seconds |
---|---|
1 | timer set in milliseconds |
Parameter 36: O (O1) Power report on change – percentage
This parameter determines the minimum change in consumed power that will
result in sending new report to the main controller.
Size: 1 Byte, Default Value: 50
SettingDescription
0 | reports are disabled |
---|---|
1 – 100 | % change in power |
Parameter 39: Minimal time between reports (O) O1
This parameter determines minimum time that has to elapse before sending new
power report on O (O1) to the main controller.
Size: 1 Byte, Default Value: 30
SettingDescription
0 | reports are disabled |
---|---|
1 – 120 | report interval in s |
Parameter 91: Water Alarm
This parameter determines to which alarm frames and how the device should
react. The parameters consist of 4 bytes, three most significant bytes are set
according to the official Z-Wave protocol specification.
Size: 4 Byte, Default Value: 0
SettingDescription
0 | no action |
---|---|
1 | open relay |
2 | close relay |
Parameter 92: Smoke Alarm
This parameter determines to which alarm frames and how the device should
react. The parameters consist of 4 bytes, three most significant bytes are set
according to the official Z-Wave protocol specification.
Size: 4 Byte, Default Value: 0
SettingDescription
0 | no action |
---|---|
1 | open relay |
2 | close relay |
Parameter 93: CO Alarm
This parameter determines to which alarm frames and how the device should
react. The parameters consist of 4 bytes, three most significant bytes are set
according to the official Z-Wave protocol specification.
Size: 4 Byte, Default Value: 0
SettingDescription
0 | no action |
---|---|
1 | open relay |
2 | close relay |
Parameter 94: Heat Alarm
This parameter determines to which alarm frames and how the device should
react. The parameters consist of 4 bytes, three most significant bytes are set
according to the official Z-Wave protocol specification.
Size: 4 Byte, Default Value: 0
SettingDescription
0 | no action |
---|---|
1 | open relay |
2 | close relay |
Parameter 119: Reset Parameters to default
Reset all configuration parameters to factory default settings. This is a
parameter to reset only configuration parameters, after reseting parameters
the Device will do power cycle, the device remain included.
Size: 1 Byte, Default Value: 0
SettingDescription
0 | Do not reset |
---|---|
1 | Reset parameters to default value |
Parameter 120: Factory Reset
Reset to factory default settings and removed from the z-wave network
Size: 4 Byte, Default Value: 0
SettingDescription
0 | Don’t do Factory reset |
---|---|
1431655765 | Do the Factory reset (hex 0x55555555) |
Technical Data
Dimensions | 42 x 37 x 16 mm |
---|---|
Weight | 27 gr |
Hardware Platform | EFR32ZG23 |
EAN | 3800235269022 |
IP Class | IP 20 |
Voltage | 230 V |
Load | 16 A |
Device Type | On/Off Power Switch |
Generic Device Class | Binary Switch |
Firmware Version | 10.13 |
Z-Wave Version | 07.13 |
Z-Wave Product Id | 0x0460.0x0002.0x0084 |
Frequency | Europe – 868,4 Mhz |
Maximum transmission power | 5 mW |
Supported Command Classes
- Ss Basic
- Switch Binary
- Meter
- Transport Service
- Association Grp Info
- Device Reset Locally
- Zwaveplus Info
- Supervision
- Configuration
- Alarm
- Manufacturer Specific
- Powerlevel
- Firmware Update Md
- Association
- Version
- Indicator
- Multi Channel Association
- Security
- Security 2
Explanation of Z-Wave specific terms
-
Controller — is a Z-Wave device with capabilities to manage the network.
Controllers are typically Gateways,Remote Controls or battery operated wall controllers. -
Slave — is a Z-Wave device without capabilities to manage the network.
Slaves can be sensors, actuators and even remote controls. -
Primary Controller — is the central organizer of the network. It must be
a controller. There can be only one primary controller in a Z-Wave network. -
Inclusion — is the process of adding new Z-Wave devices into a network.
-
Exclusion — is the process of removing Z-Wave devices from the network.
-
Association — is a control relationship between a controlling device and
a controlled device. -
Wakeup Notification — is a special wireless message issued by a Z-Wave
device to announces that is able to communicate. -
Node Information Frame — is a special wireless message issued by a
Z-Wave device to announce its capabilities and functions.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>