LAVEX 457LAVBP8QT Backpack Vacuum Owner’s Manual

June 13, 2024
LAVEX

LAVEX 457LAVBP8QT Backpack Vacuum

LAVEX-457LAVBP8QT-Backpack-Vacuum-FIG- \(10\)

Product Information
The Lavex Backpack Vacuum is a powerful and efficient cleaning appliance designed to make your cleaning tasks easier. With a model number of 457LAVBP8QT, this vacuum operates at 120V, 12A, and
1400W. It is ETL certified for use in the United States and Canada.

Product Usage Instructions
Replacing the HEPA Bag

  1. To open the canister lid, pull up the canister lid tabs on each side of the unit and remove the canister lid.
  2. Pull the tab on the HEPA bag holder out slightly and flip it upwards.
  3. Hold the HEPA bag in your hand and slide/pull it out of the bag holder to dispose of it.
  4. Insert/slide the new bag into the bag cover guides, ensuring that the cardboard face rests securely.

Cleaning the Cloth Shake-Out Bag

  1. Remove the Shake-out bag from the canister.
  2. Hold the handle of the bag and shake it vigorously over a garbage receptacle, preferably outdoors.
  3. If necessary, hand wash the cloth shake-out bag with warm water and let it air dry before reinserting it into the canister lip.
  4. Regularly inspect the shake-out bag for tears or damage, and replace it if necessary.

Cleaning or Replacing the HEPA Pre-Motor Filter

Note: The HEPA pre-motor filter is responsible for filtering out tiny dust particles and airborne allergens.

  1. Remove the shake-out bag from the canister to access the HEPA pre-motor filter.
  2. To remove the HEPA pre-motor filter, place your index finger underneath the edge of the filter and press the tab toward the center to release it. Lift the side of the filter and pull upwards.
  3. Vigorously tap clean the HEPA pre-motor filter on a hard surface to remove any residual dust.
  4. You can wash the HEPA pre-motor filter by running it under tap water, focusing on the dirty side. Do this at least once a month or when suction appears to be decreased.
  5. Shake off any excess water and allow the filter to dry completely before reinserting it.
  6. If the filter cannot be cleaned or is damaged, replace it with a new one.
  7. To reinsert the filter, place it over the tabs and press down until you hear two clicks, indicating the correct installation.

Cleaning the Exhaust Filter
Instructions for cleaning the exhaust filter are not provided in the given text extract from the user manual. Please refer to the complete user manual for detailed instructions on cleaning the exhaust filter.

IMPORTANT SAFETY INSTRUCTIONS

When using an electrical appliance, basic precautions should always be followed, including the following:
READ ALL INSTRUCTIONS BEFORE USING THIS APPLIANCE
WARNING
To reduce the risk of fire, electric shock, or injury:

  1. Do not leave the vacuum cleaner when plugged in. Unplug from the outlet when not in use and before servicing.
  2. Electrical shock may occur if used outdoors or on wet surfaces.
  3. Do not allow to be used as a toy. Close attention is necessary when used by or near children.
  4. Use only as described in this manual. Use only the manufacturer’s recommended instructions.
  5. Do not use a damaged cord or plug. If the appliance is not working as it should, has been dropped, damaged, left outdoors, or dropped into water, contact Lavex Janitorial.
  6. Do not pull or carry by cord, use the cord as a handle, close a door on the cord, or pull the cord around sharp edges of corners. Do not run the appliance over the cord. Keep the cord away from heated surfaces.
  7. Do not unplug by pulling on the cord. To unplug, grasp the plug, not the cord.
  8. Do not handle the plug or appliance with wet hands.
  9. Do not put any objects into openings. Do not use any opening blocked; keep free of dust, lint, hair, and anything that may reduce airflow.
  10. Keep hair, loose clothing, fingers, and all body parts away from openings and moving parts.
  11. Do not pick up anything that is burning or smoking such as cigarettes, matches, or hot ashes.
  12. Do not use without filters in place.
  13. Turn off all controls before unplugging.
  14. Use extra care when cleaning on stairs.
  15. Do not use to pick up any liquids, including flammable or combustible liquids such as gasoline, or use in areas where they may be present.
  16. Connect to a properly grounded outlet only.
  17. This appliance is not intended for use by persons (including children) with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.

GETTING TO KNOW YOUR LAVEX VACUUM

  1. Replacement 1.5” Lid Grey (457BPLID)
  2. Replacement Hose 1.5” (457BPHOSE5)
  3. Floor Tool w/Scallops 1.5” (457BPFTS)
  4. Crevice Tool 1.5” (457BPCREVICE)
  5. Round Dusting Brush 1.5” (457BPBRUSHO)
  6. Floor Tool with Bristles 1.5” (457BPFTB)
  7. Upholstery Tool w/Brush 1.5” (457BPBRUSHU)
  8. 1.5” Aluminum Wand (457BPWANDH “hose end” and 1.5” 457BPWANDU “utensil end”)
  9. HEPA Bag (457BAG8QT)
  10. Reusable Cloth Shake-Out Bag (457BAGSHAKE)
  11. HEPA Pre-Motor Filter and Exhaust Filter Set (457BPFILKIT)
  12. Exhaust Filter Cover (457BP18)

Operating Instructions

Warning: To reduce the risk of electric shock, the power cord must be disconnected from the wall outlet before removing and replacing filters or performing maintenance.

Replacing the HEPA Bag

  1. To open the canister lid, pull up the canister lid tabs on each side of the unit and remove the canister lid. (Fig.1)
  2. Pull the tab on the HEPA bag holder out slightly and flip upwards. (Fig. 2)
  3. Holding the HEPA bag in your hand, slide/pull it out of the bag holder and dispose.
  4. Insert/slide a new bag. The cardboard face should rest securely in the bag cover guides. (Fig. 3)

Cleaning the Cloth Shake-Out Bag

  1. Remove the Shake-out bag from the canister. Hold the handle of the bag shaking vigorously over a garbage receptacle and preferably outdoors. (Fig. 4)
  2. As necessary, hand wash the cloth shake-out bag with warm water and let it air dry before reinserting it onto the canister lip. Inspect shake-out bag regularly for tears or damage. Replace the shake-out bag if damaged or torn.

Cleaning or Replacing the HEPA Pre-Motor Filter
Important Please Note: The HEPA pre-motor filter will stop most of the tiniest dust particles and airborne allergens from re-entering the air you breathe. Because of this incredible filtration performance, the HEPA pre-motor filter will accumulate many fine dust particles that are difficult to see. Be assured that the HEPA pre-motor filter is doing the job. Clean the HEPA pre-motor filter when dirty as described in this section.

  1. Remove the shake-out bag from the canister. The HEPA pre-motor filter is located underneath the shake-out bag. To remove the HEPA pre-motor filter, place your index finger underneath the edge of the premotor filter, and using your thumb press the tab toward the center of the filter to release, then lift the side of the HEPA pre-motor filter and pull upwards on the filter.
  2. Vigorously tap clean the HEPA pre-motor filter on a hard surface to remove any residual dust that might still be on the HEPA pre-motor filter.
  3. You can wash the HEPA pre-motor filter by running it under the tap and allowing the water to run on the dirty side at least once a month or when suction appears to be decreased.
  4. Shake off any excess water and allow to dry completely before reinserting it.
  5. Replace the Pre-Motor Filter if it cannot be cleaned or if damaged.
  6. To reinsert, place the filter over the tabs and press down. You should hear two “clicks” if installed correctly. (Fig. 5)

Wash or Replace at least once a year or when suction appears reduced.
WARNING Allow 24 hours for drying before replacing in the unit.

Cleaning the Exhaust Filter

  1. Pull up and hold the exhaust tab and pull out the exhaust cover. (Fig. 6)
  2. Remove the exhaust filter.
  3. As necessary, hand wash or replace the cloth filter with tap water and let dry before reinserting it.

Assembling Your Vacuum
Push/press fit the hose into the lid opening. (Fig 7)LAVEX-457LAVBP8QT-
Backpack-Vacuum-FIG- \(6\)

To connect the hose and attachment wand, slide the hose over the hose end wand attachment and over the bump by approx. ½ inch. (Fig. 8)
Take the hose end attachment wand and connect it to the lower attachment wand (utensil end). (Fig.9)

Secure the utensil to the end of the wand. Align the brass ring with the groove on the tool to ensure a secure fit (Fig. 10)

Using Your Vacuum

  1. Connect the extension cord to the extension cord relief (Fig 12) and connect the vacuum plug to an extension cord. Plug the extension cord into the electrical outlet.
  2. Connect a hose and wand and/or utensil.
  3. Correctly place shoulder straps on each shoulder and secure the waistband with hook and loop strips. (Fig. 11)LAVEX-457LAVBP8QT-Backpack-Vacuum-FIG- \(10\)

Warranty/Service Information

The Lavex Vacuum Limited Warranty: To the original user purchasing the Lavex Vacuum, warrants that the vacuum will be free of defects in material and manufacture for a period of one (1) year from the date of purchase. Should any failure to conform to this warranty appear within this period, Lavex Janitorial will, at its option, repair or replace the defective product. Exclusions to warranty coverage: The above warranty will not apply to any special configurations or to any units that have been modified, or damaged by negligence, misuse, accident, or failure to follow Lavex Instruction Manual. Consumable supplies, such as filters, accessories, and motor brushes are not covered by this warranty.

Disclaimer of Warranty: EXCEPT FOR THE IMPLIED WARRANTIES OF TITLE AND AGAINST PATENT INFRINGEMENT, LAVEX JANITORIAL MAKES NO OTHER WARRANTIES WITH RESPECT TO THE LAVEX BACKPACK VACUUM CLEANER, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

Limitation of Liability: LAVEX JANITORIAL WILL NOT BE LIABLE UNDER ANY CIRCUMSTANCES FOR ANY COINCIDENTAL, SPECIAL, OR CONSEQUENTIAL DAMAGES OR ECONOMICAL LOSS, BASED UPON BREACH OF WARRANTY, BREACH OF CONTRACT, NEGLIGENCE, STRICT LIABILITY IN TORT OR ANY OTHER LEGAL THEORY, EVEN IF LAVEX JANITORIAL HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES INCLUDING, BUT NOT LIMITED TO LOSS OF PROFITS, REVENUE, EQUIPMENT USE, DATA OR INFORMATION OF ANY KIND. THE LIABILITY OF LAVEX JANITORIAL SHALL NOT UNDER ANY CIRCUMSTANCE, EXCEPT AS EXPRESSLY PROVIDED HEREIN, EXCEED THE PRICE OF THE LAVEX BACKPACK VACUUM.