BROAN NuTone VT9W HE Series Wall Control Owner’s Manual

June 13, 2024
Broan NuTone

VT9W HE Series Wall Control
Owner’s Manual

VT9W HE Series Wall Control

INSTALLATION AND OWNER GUIDE FOR 40355, 40455 AND VT9W WALL CONTROLS

WALL CONTROL COMPATIBILITY

REFER TO THE WALL CONTROL COMPATIBILITY CHART INCLUDED WITH THIS WALL CONTROL.

WALL CONTROL INSTALLATION

WARNING
IT IS RECOMMENDED TO WEAR SAFETY GLASSES AND GLOVES WHILE PERFORMING THESE INSTRUCTIONS. ALWAYS DISCONNECT THE UNIT BEFORE MAKING ANY !
CONNECTIONS. FAILURE TO DISCONNECT POWER COULD RESULT IN ELECTRIC SHOCK OR DAMAGE TO THE WALL CONTROL OR ELECTRONIC MODULE INSIDE THE UNIT.
CAUTION
FAILURE TO COMPLY WITH THE FOLLOWING CAN CAUSE ERRATIC OPERATION OF THE UNIT AND/OR THE WALL CONTROL:
NEVER INSTALL MORE THAN ONE X-TOUCH MAIN WALL CONTROL PER UNIT. MAKE SURE THAT THE WIRES DO NOT SHORT-CIRCUIT BETWEEN THEMSELVES OR BY TOUCHING ANY OTHER COMPONENTS ON THE WALL CONTROL. AVOID POOR WIRING CONNECTIONS. TO REDUCE ELECTRICAL INTERFERENCE (NOISE) POTENTIAL, DO NOT RUN WALL CONTROL WIRING NEXT TO CONTROL CONTACTORS OR NEAR LIGHT DIMMING CIRCUITS, ELECTRICAL MOTORS, DWELLING/BUILDING POWER OR LIGHTING WIRING, OR POWER DISTRIBUTION PANEL.

  1. UNPLUG THE VENTILATION UNIT FROM POWER SOURCE.

  2. CUT A 2 7/8” X 1 3/8” HOLE IN A WALL, AT A CONVENIENT LOCATION FOR THE WALL CONTROL. ROUTE THE CABLE FROM THE UNIT TO THIS HOLE.
    BROAN NuTone VT9W HE Series Wall Control - assembly 1 NOTE: DIMENSIONS SHOWN ARE FOR AN INSTALLATION WITHOUT WALL BOX.

  3. TEMPORARILY PLACE THE SWITCH OVER THE HOLE AND MARK BOTH MOUNTING SCREW HOLE POSITIONS.
    BROAN NuTone VT9W HE Series Wall Control - assembly 2

  4. REMOVE THE SWITCH, DRILL BOTH SCREW HOLES (3/16” Ø) IN WALL AND INSERT WALL ANCHORS (INCLUDED).

  5. STRIP THE END OF THE CABLE TO ACCESS THE 4 WIRES. STRIP THE END OF EACH WIRE. USING A SMALL BLADE SCREWDRIVER, CONNECT EACH WIRE TO ITS CORRESPONDING TERMINAL, ON THE BACK OF THE WALL CONTROL: YELLOW WIRE TO “Y”, BLACK WIRE TO “B”, RED WIRE TO “R”, AND GREEN WIRE TO “G”.
    BROAN NuTone VT9W HE Series Wall Control - assembly 3

  6. MOUNT THE WALL CONTROL TO THE WALL. PLUG THE VENTILATION UNIT AND TEST THE WALL CONTROL OPERATION.

ERROR CODES

ERROR CODES SOLUTION
A 2-DIGIT ERROR CODE (E1, E2, ETC.) IS DISPLAYED ON WALL CONTROL SCREEN.

ENSURE THAT THE COLOR CODED WIRES HAVE BEEN CONNECTED TO THEIR APPROPRIATE PLACE.
• ENSURE THAT THE WIRES ARE CORRECTLY CONNECTED.
• PRESS AND HOLD SIMULTANEOUSLY FOR 8 SECONDS ON % HUM, MODE AND TURBO KEYS TO RESET THE WALL CONTROL. THE USER PREFERENCES WILL HAVE TO BE RESET.
A 3-DIGIT ERROR CODE (E21, E22, ETC.) IS DISPLAYED ON WALL CONTROL SCREEN.| • PROBLEM WITH THE VENTILATION UNIT. CONTACT YOUR INSTALLATOR.
A 10-SECOND COUNTDOWN IS DISPLAYED ON WALL CONTROL SCREEN.| • WAIT UNTIL THE END OF THE COUNTDOWN, WITHOUT PRESSING ANY KEY.

WALL CONTROL USE

BACKLIGHT       IF THE BACKLIGHT IS NOT ILLUMINATED, PRESSING ON MODE,  % HUM OR TURBO KEY WILL ACTIVATE IT. THE BACKLIGHTREMAINS ILLUMINATED FOR 10 SECONDS AFTER THE LAST KEY IS PRESSED (NO MATTER THE KEY).
OPERATING MODES
NOTE:
IF THE BACKLIGHT IS NOT ILLUMINATED, PRESS ON ANY KEY TO ACTIVATE THE WALL CONTROL.
PRESS THE MODE KEY TO CHOOSE THE OPERATION MODE OF THE VENTILATION UNIT (EXCEPT TURBO MODE).
OPERATING MODE WILL THEN APPEAR ON LCD SCREEN (STANDBY, RECIRC, 20 min/h, CONT, SMART).
STANDBY
PUT THE UNIT ON STAND-BY MODE, SO IT WILL ONLY RESPOND TO OVERRIDE WALL CONTROLS (IF PRESENT). ON LCD SCREEN, ONLY THE HOUSE IS VISIBLE SHOWING THE CONTROL IS POWERED ON. THIS IS THE FACTORY SET DEFAULT MODE.
RECIRC
AIR IS RECIRCULATED INSIDE THE HOUSE ON HIGH SPEED.
20 MIN/H
THE VENTILATION UNIT EXCHANGES AIR INTERMITTENTLY ON A ONE HOUR CYCLE AS FOLLOWS: OFF FOR 40 MIN. (OR RECIRCULATION FOR 40 MIN. ON LOW OR HIGH SPEED, SEE BACK PAG E ) AND THEN EXCHANGE AIR DURING 20 MIN. ON LOW SPEED. REPEAT CYCLE AFTER THE 20 MIN. OF AIR EXCHANGE.
CONT
AIR IS EXCHANGED WITH THE OUTDOORS AT THE MINIMUM BLOWER SPEED.
SMART
AIR EXCHANGE IS MANAGED ACCORDING TO INDOOR HUMIDITY MEASURED BY THE WALL CONTROL AND OUTDOOR TEMPERATURE. IN SMART MODE, THE SMART ICON APPEARS AS WELL AS THE CURRENT OPERATING MODE CALLED BY SMART (SEE BELOW).  BROAN NuTone
VT9W HE Series Wall Control - assembly 11NOTE: THE ECO MODE SET THE UNIT OPERATION TO STANDBY FOR 50 MINUTES (OR IN RECIRC MODE FOR 50 MINUTES; SEE SETTINGS SECTION) AND THEN EXCHANGE AIR DURING 10 MINUTES ON LOW SPEED. THIS MODE IS EXCLUSIVELY ACTIVATED BY SMART MODE.
THE CHART BELOW SHOWS THE OPERATING MODES CALLED BY SMART MODE, ACCORDING TO THE INDOOR HUMIDITY PERCENTAGE AND THE OUTDOOR TEMPERATURE.BROAN NuTone VT9W
HE Series Wall Control - assembly 12* THIS AREA REPRESENTS STANBY MODE.

FUNCTIONS

TURBO FUNCTION
PRESS THE TURBO FUNCTION KEY TO TURN THE UNIT ON AIR EXCHANGE IN HIGH SPEED DURING 4 HOURS, THEN, THE UNIT WILL GET BACK TO ITS PREVIOUS OPERATION MODE.
BROAN NuTone VT9W HE Series Wall Control - assembly 13THE TURBO ICON IS FLASHING DURING THE 4-HOUR CYCLE. TO EXIT THIS FUNCTION BEFORE THE END OF ITS 4-HOUR CYCLE, PRESS ON TURBO OR MODE KEY; THE UNIT WILL GET BACK TO ITS PREVIOUS OPERATION MODE.
PRESS AND HOLD THE TURBO FUNCTION KEY DURING 3 SECONDS TO TURN THE UNIT ON AIR EXCHANGE IN HIGH SPEED CONTINUOUSLY.
BROAN NuTone VT9W HE Series Wall Control - assembly 14THE TURBO ICON APPEARS AND STAY CONTINUOUSLY. TO EXIT THIS TURBO MODE, PRESS ON TURBO OR MODE KEY; THE UNIT WILL GET BACK TO ITS PREVIOUS OPERATION MODE.
DEHUMIDISTAT FUNCTION THE DEHUMIDISTAT FUNCTION HAS BEEN CREATED TO MANAGE THE INDOOR RELATIVE HUMIDITY EXCESS. WHEN THE ACTUAL HOMERELATIVE HUMIDITY PERCENTAGE (RH %) DETECTED IS OVER THE SET VALUE, DROPS APPEARS ON SCREEN AND THE CONTROL OVERRIDES THE CURRENT MODE, TURNING ON THE UNIT ON HIGH SPEED EXHANGE UNTIL THE INDOOR RELATIVE HUMDITY % SET IS REACHED. THE UNIT THEN RETURNS TO ITS PREVIOUS OPERATION SETTING. REFER BELOW TO FIND OUT HOW TO SET THE INDOOR RELATIVE HUMIDITY %.
HOW TO ENABLE AND DISABLE THE DEHUMIDISTAT FUNCTION:BROAN NuTone VT9W
HE Series Wall Control - assembly 16

SETTINGS

HOW TO SET THE INDOOR RELATIVE HUMIDITY (RH %) LEVELBROAN NuTone VT9W
HE Series Wall Control - assembly 17 HOW TO SET THE UNIT OPERATION IN THE REMAINING 40 MINUTES ON 20 MIN/H MODE AND HOW TO SET THE UNIT DEFROST CYCLE TYPEBROAN NuTone VT9W HE
Series Wall Control - assembly 18

PROTECTION MODE

THIS ICON APPEARS TO SHOW WHEN THE VENTILATION UNIT IS IN PROTECTION MODE. THIS SPECIAL MODE HAS BEEN CREATED TO PROTECT THE VENTILATION UNIT FROM SPECIFIC CONDITIONS (E.G.: OUTDOOR TEMPERATURE COLDER THAN -25°C). THERE IS NO ACTION TO BE TAKEN WHEN THIS ICON APPEARS, IT WILL DISAPPEAR BY ITSELF.

MAINTENANCE INDICATOR

THIS ICON FLASHES WHEN IT IS TIME TO PEFORM THE MAINTENANCE. REFER TO THE VENTILATION UNIT USER GUIDE. ONCE THE UNIT MAINTENANCE IS DONE, PRESS SIMULTANEOUSLY ON BOTH MODE AND TURBO KEYS TO RESET THE MAINTENANCE INDICATOR. THIS WILL ERASE THE ICON FROM THE SCREEN.