IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions should always be
followed including the following:
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
- DANGER- Risk of shock- Disconnect power before installation. DANGER
- This luminaire must be installed in accordance with the NEC or your local electrical code. If you are not familiar with these codes and requirements, consult a qualified electrician.
- Suitable for Wet Locations.
- Suitable for mounting within 1.2 m (4 ft) of the ground.
SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE
INSTALLATION
- Thread the floodlight mounting arm into the 1/2″ opening of the cover and secure it with 1/2″ locknut. Using a sealing compound on the threads will ensure a water tight seal.
FIXTURE WIRING
Fixture is equipped with a 120V driver. Make sure supply voltage is 120V AC.
- Connect supply ground to fixture ground (green or bare) lead. Connect supply common to fixture neutral (white) lead. Connect supply Vin (120V AC) to fixture hot (black) lead.
Tuck all wires carefully into wiring chamber ensuring that no wires are pinched.
TO AIM FIXTURE
- Loosen the side bolt connected to the arm knuckle to aim the fixture up or down. Re-tighten bolt to secure the fixture in the desired position.
FCC NOTICE Class A
CAUTION: Changes or modifications not expressly approved could void your authority to use this equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. CAN ICES-005 (A)/NMB-005 (A)
NOTES:
- When mounting the fixture in an inverted position (1/2″ fitter above fixture), mount fixture to a watertight junction box and cover. Also, caulk the conduit openings, around the junction box cover, and the wire entry end of the 1/2″ fitter with a high grade caulking material, such as silicone rubber, to ensure water does not enter fixture through 1/2″ fitter.