CAE BPL400 Femoral Vascular Access Ultrasound Training Model User Guide
- June 12, 2024
- CAE
Table of Contents
- CAE BPL400 Femoral Vascular Access Ultrasound Training Model User Guide
- Cautions and Warnings
- General Precautions
- Latex-Free
- Needles and Catheters
- Fluids System
- Service and Repair
- Introduction
- Anatomy
- Introduction
- Equipment Overview
- Using the Training Model
- Setup
- Training
- Ultrasound Scanning
- Ultrasound-guided Procedures
- Femoral Vascular Access Ultrasound Training Model (BPL400)
- Method B – Re-injection:
- Care and Maintenance
- Storage and Transport
- Cleaning
- Replacing the Tissue Insert
- Troubleshooting
- Applies to BPL400 and BPL400-DVT only
- Fluid Overfill
- Removing Air
- Help and Technical Assistance
- Read More About This Manual & Download PDF:
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
CAE BPL400 Femoral Vascular Access Ultrasound Training Model User Guide
Cautions and Warnings
Cautions and Warnings
Read this user guide, including all cautions and warnings, before you use your CAE Blue Phantom™ ultrasound training model. Use this product only as described in this guide. If you use the product incorrectly, it may be unsafe and will void your warranty. Keep this information for future reference.
General Precautions
- Make sure the training model is set up on a stable, sturdy work surface such as a bed, stretcher, or table that will not collapse and cause injury to
- Heavier training models should be placed on a patient bed or stretcher rated to support such
- Place the model on smooth surfaces Rough or uneven surfaces can leave impressions on the skin and damage the model.
- Do only the procedures supported by each product as described in this
- Use only needles to access
- Do not use or store other sharp objects such as scissors, scalpels, or box-cutters with the training
- Do not pull on the training model This can cause the skin to tear.
- Do not mark directly on the training model as this will permanently damage
- Do not insert any objects or tools into the model except for the equipment, accessories, or medical supplies intended for use with this
- Do not use chemical solvents on the
- Clean the training model with water and a light soap solution Do not immerse the model or use large amounts of liquid to wash it.
Latex-Free
- All CAE Blue Phantom training models, products, and accessories are manufactured only of materials that do not contain
Needles and Catheters
- Use only new, sharp, unbent 18-21 gauge needles or 7F catheters. Smaller needles (higher than 22 gauge) can bend during use and damage the
- The self-healing feature of CAE Blue Phantom simulated tissue applies only to needle sticks from 18-21 gauge needles. Healing is not guaranteed if needles larger than 18 gauge, scalpels, or other sharp implements are used to cut into or pierce the
- Replace needles after ten Dull needles can damage the model.
- Use extreme caution when using needles during training to avoid
Cautions and Warnings
Fluids System
- Use only CAE Blue Phantom Other fluids can affect the imaging quality and promote fungal or bacterial growth, and may void your warranty. Use fluids only as directed.
- Do not substitute any other fluid unless indicated by this
- Do not modify the fluid reservoirs or any assembly
- Protect your eyes, skin, and clothing against accidental fluid Refer to the Material Safety Data Sheet (MSDS) for guidance.
º May irritate eyes or skin; flush well with water.
º May contain pigments that stain clothing; wash immediately with cold soapy water.
- Fluid is not intended for human If accidental ingestion occurs, drink a glass of water and consult a physician.
Service and Repair
- The CAE Blue Phantom training models are not user-serviceable. Only a trained technician may open or disassemble the
- Unauthorized use or handling of the model may void the
- If you have a problem with your product, contact CAE Customer
Introduction
Introduction
This user guide describes the features, use, and care of the following training models:
- CAE Blue Phantom Femoral Vascular Access Ultrasound Training Model (BPL400)
- CAE Blue Phantom Femoral Vascular Access Ultrasound Training Model with Deep Vein Thrombosis (BPL400-DVT)
- CAE Blue Phantom Foreign Body Identification Ultrasound Training Model, leg (BPL-550)
- CAE Blue Phantom Soft Tissue Biopsy Ultrasound Training Model, leg (BPL600)
These models are intended as platforms for the practice of ultrasound examination and various ultrasound- guided procedures. Each is presented as a leg base with the use-specific insert. The inserts are interchangeable.
Anatomy
Ultrasound Training Model
CAE Blue Phantom training models are constructed using our patented Simulex™
ultrasound tissue which has imaging characteristics that mimic human tissue.
The models contain skeletal components so the user will encounter the same
imaging landmarks as in a human patient.
The internal anatomy or features of each leg model are as follows:
- Femoral Vascular Access Ultrasound Training Model (BPL400) and Femoral Vascular Access Ultrasound Training Model with Deep Vein Thrombosis (BPL400-DVT)
º Saphenous vessel
º Femoral vessel
º Accessory vessels
These models are delivered prefilled with CAE Blue Phantom ultrasound fluid. More information can be found in the Using the Training Model section of this guide.
Introduction
- Foreign Body Identification Ultrasound Training Model, leg (BPL-550)
º Metal projectile BBs
º Metal shrapnel fragments
º Wooden splinters
º Metal needles
º Large glass fragments
º Glass shards
- Soft Tissue Biopsy Ultrasound Training Model, leg (BPL600)
º 20 hyperechoic, hypoechoic, and echolucent masses (4 mm to 11mm)
Equipment Overview
The following items are included with your shipment:
- Ultrasound training model
- Red ultrasound refill fluid (BPL400 and BPL400-DVT only)
The following additional items are required for training but not included in your purchase:
- Ultrasound system with appropriate transducer
- Ultrasound gel
- Vascular access equipment as per local protocol (BPL400 and BPL400-DVT only)
- Biopsy equipment as per local protocol (BPL600 only)
CAE Blue Phantom training models are compatible with any diagnostic ultrasound
system. General frequency ranges for diagnostic ultrasound imaging are
2-20MHz.
Optional accessories or consumables for your model are available to purchase
on the CAE website:
- BPLI405 Femoral vascular access replacement insert
- BPLI405-DVT Femoral vascular access replacement insert with DVT
- BPLI410 Soft tissue biopsy replacement insert
- BPLI410 Foreign body identification replacement insert
- BRS180-RED Red ultrasound refill fluid (for BPL400 and BPL400-DVT only)
Using the Training Model
Using the Training Model
This section has information and instructions about the setup and use of the
training model and any specific training procedures.
Setup
Follow the guidelines below to unpack and set up your CAE Blue Phantom training model.
- Open the shipping carton:
º Use extreme caution with sharp tools, such as a box cutter, to avoid damage to the training model.
- Unpack the equipment:
º Remove the training model from its shipping container. For heavier models, use proper lifting techniques to prevent bodily injury.
º Review the equipment, accessories, and supplies to make sure all necessary pieces are present. See the Equipment Overview section of this guide for a list of items included with this model.
- Set up for training:
º Put the model on a stable patient bed, stretcher, or table.
º Prepare your ultrasound system and equipment.
º Gather any procedural equipment and supplies.
Training
This section provides information about using your model for training and practice.
Ultrasound Scanning
Note: CAE Blue Phantom products do not teach ultrasound procedures or
techniques. Refer to your institution or training program for more
information.
To scan with your training model and conduct a simulated ultrasound-guided
procedure:
- Place the model in the appropriate position for
- Place ultrasound gel on the transducer or on the training model in an adequate quantity so that the transducer slides effortlessly on the Add more gel as needed.
- Adjust the ultrasound system controls per your training protocol and the manufacturer’s Optimize the image with the ultrasound controls as needed.
Using the Training Model
Ultrasound-guided Procedures
Three of the leg models also support specific ultrasound-guided needle
procedures. For each model listed below, use your normal protocol and
equipment, and follow your institution’s policies and guidelines.
Note: The Foreign Body Identification model does not support any ultrasound-
guided needle or extraction procedures.
Do not use antiseptics, such as iodine, on the model. This will cause
permanent damage.
Femoral Vascular Access Ultrasound Training Model (BPL400)
Femoral Vascular Access Ultrasound Training Model with Deep Vein
Thrombosis (BPL400-DVT)
These models are intended as a platform for the practice of ultrasound-guided
femoral venous access and identification of DVT (BPL400-DVT only).
During use of this training model, users may withdraw fluid to confirm needle
placement after the vessel has been accessed. Any fluid withdrawn must be
refilled because it is important to maintain the fluid level within the
vessels. During periods of non-use, fluid may also evaporate from inside the
model. Refill with one of the these methods
Method A – Syringe Fill (also to remove air):
- Fill a syringe half-full.
- Remove the femoral
- Locate the dimples on the end of the These are the locations to inject fluid.
- Inject 10 ml of fluid.
- Remove 5 ml of fluid along with any
- Repeat steps 4 and 5 until any air is removed and the vessels are
Method B – Re-injection:
- During use, the user immediately injects any withdrawn fluid back into the model at the access
- Take care not to inject any air into the model when using this NOTE: This method cannot be used with full catheter placements.
Soft Tissue Biopsy Ultrasound Training Model, leg (BPL600)
This model is intended as a platform for the practice of ultrasound-guided
soft tissue biopsies.
When a tissue sample is taken from the leg insert, it leaves an air-filled
space the same size as the sample. Once a tissue sample is removed, it cannot
be re-inserted. Therefore, this product has a finite lifespan.
Care and Maintenance
With proper care, your training model will remain in optimal condition and ready for use.
Storage and Transport
Follow these guidelines to properly store or transport your model:
- Storage temperature degree range: 45 to 85 °F (7 to 29 °C)
- Do not store in contact with other models or hard objects as the pressure can damage the Simulex Do not stack multiple training models on top of each other.
- Ensure any tubes are not pinched or compressed under the This will damage the tubes and void the warranty.
- When models with inserts are stored standing up for long periods of time, gravity may cause the insert to deform Remove the insert and let it sit for a few days to regain its shape.
- Store the model with some fluid in any vessels and fluid If these become dry, it will damage the model and and cause poor ultrasound imaging.
- If fluid was infused into the model during training, remove excess fluid after each training If you store the model with too much fluid inside, it can cause damage.
- Transport the model securely so it does not
- Do not carry by the tubes or use them as handles as this will damage the
Cleaning
To maintain the product skin for the lifespan of the product, clean the exterior of the model after each use. Follow these steps:
- Mix one cup of tap water with ¼ teaspoon of mild liquid soap (such as dish soap).
- Gently clean the model’s exterior with the soap mixture and a soft, non-abrasive sponge or
- Rinse lightly with clean
- Dab or pat with a clean, soft, lint-free cloth to dry the product after Do not wipe or rub the skin, which can damage it.
- After the model has dried completely, lightly coat the external surface of the model with baby powder and dust off any
Replacing the Tissue Insert
To replace the insert, you will need:
- Replacement insert
Care and Maintenance
Follow these steps:
- Position your training model in the upright
- Gently lift up and pull the insert out
- Place the new insert into the
- Adjust the insert as needed so it aligns with the surface of the
Troubleshooting
Applies to BPL400 and BPL400-DVT only
This section provides information to identify and fix problems that may occur with the product.
Fluid Overfill
You can overfill fluid spaces and vessels if you inject too much fluid. Overfill does not usually result in permanent damage, but you should correct it as soon as possible. To alleviate overfill, withdraw the excess fluid with the syringe. Access the fluid space through one of the dimples at the end of the femoral insert.
Removing Air
Fluid can evaporate from the model during shipment or during extended periods of non-use. Air may also enter through accidental injection during fluid filling or training use. This may cause the Simulex tissue to stick together in some areas, preventing fluid from circulating. Remove any air from the model for optimal performance.
To remove air, use the syringe fill steps found in the Using the Training Model section of this guide.
Help and Technical Assistance
For assistance, contact CAE Customer Support. Contact information for all regions is available on the back cover of this guide and on the CAE Healthcare website.
Read More About This Manual & Download PDF:
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>