ThinkGrow LLT-1 Smart Light Lifter System User Manual
- June 12, 2024
- ThinkGrow
Table of Contents
ThinkGrow LLT-1 Smart Light Lifter System
SAFETY PRECAUTIONS
Read the installation and operation instructions carefully before installing
and operating this device. Proper adherence to these instructions is
essential.
The maximum amperage for the Light Lifter is 1.5 amps. The maximum weight for
the Light Lifter is~ 1321bs 160kg.
WARNING
Users are responsible for the connection and safe installation and usages of
the devices.
It is highly recommended to have a certified personnel or licensed electrician
to install your light lifter system.
Ensure the existing electrical system can support the voltage and current
requirements.
The light lifter is heavy. It may cause serious injury and/or equipment damage
if dropped. Be careful when installing. Secure the light lifter using
appropriate mounting hardware. Follow installation instructions carefully.
Ensure the building structure, mounting solutions and components being used
are rated to support the weight of the lifter and the light fixtures.
CAUTION
Read all instructions carefully before installation.
This product is not intended for use by any persons and children with reduced
physical, sensory or mental capabilities or lack of experience and product
knowledge.
The device is designed to be installed INDOORS IN A SPACE THAT IS PROTECTED
FROM RAIN AND FLOODING.
General maintenance is not required. DO NOT clean the interior, steel cable of
the light lifter with any chemicals that might cause damage. To clean the
steel cable, use a damp cloth only, let the steel cable fully dry before
retracting the cable.
ThinkGrow Smart Light Lifter (LLT-1)
OVERVIEW
The LLT-1 light lifter is part of Think Grow modular light lifter system.
Its cutting edge synchronized multi-lifter operation provides users with a
customizable, expandable and easy to install system. The lifter is ETL listed
and cable length is up to 1321bs, 8.8ft.
The light lifter design enables easy, two-man installation. Unlike the
traditional lifter system where precise calculation and teams of engineers are
needed, the LLT-1 reduces assembly time and manpower without compromising
quality or safety. The easily expandable modular lifter system provides
maximum flexibility and user customization. The light system can also connect
to the Hydro-X Pro Control System for additional features. The LLT-1 can lift
and lower multiple lights and connect to other LLT-1 lifters via daisy chain
data cables, enabling users to connect, control and program synchronized
operation.
SPECIFICATION
Input Voltage: | 100-240V, 50/ 60Hz |
---|---|
Input Power: | sl00W |
Lifting Range: | s 8.8 ft/ 2.7m/ 106inchs |
Maximum Lifting Weight: | s 1321bs / 60kg |
Working Environments: | Temperature 32-104°F / 0-40°C Humidity s90% |
Product Dimensions: | 22.51″ I 572mm(L) x 10.31″ / 265mm(W) x 7.67″ / |
195mm(H)
Product Weight:| 22.71bs / 10.3kg
PACKAGE CONTENT
1 x ThinkGrow Smart Light Lifter (LLT-1)
1 x Power Cable
1 x ECS-7 Signal Cable
INSTALLATION’
The LLT-1 module can be mounted directly to a ceiling joist, unistrut or other
secured structures using appropriate fasteners to secure the LLT-1.
Ensure the mounting solution is rated and installed by a certified
professional. The mounting structure must be able to support the weight of the
LLT-1 and the weight of the lifted fixture. While complying with the rated
lift capacity of the LLT-1.
There are two mounting holes to secure the lifters overhead.
Minimum requirements are 3/8″ or 10mm screws. (Screws and washers are not
included in the package)
*Caution: Users are responsible to ensure all building structure,
mounting solutions and components are rated and structurally sound.
OPERATION INSTRUCTIONS
-
There are manual ascend and descend buttons on the control panel near the steel cable side of the lifter. These manual controls can be used when synchronizing multiple lifters to work together.
a. Press and hold the ascend button to lift up the fixture.
b. Press and hold the descend button to lower the fixture. -
The manual ascend/descend button functions the same as the wired remote control – the LRC-1.
*Custom lifting Range limit can be set up when paired with the LRC-1.
LED LIGHT INDICATOR
LED Indicator:
- Solid Green – Normal operation status, there is connection with the remote.
- Flashing Green – Normal operation status, there’s no pairing/ connection with the remote.
- Flashing Red – Error message, please refer to the troubleshooting table.
TROUBLESHOOTING
LED Light Indicator | (Error) status | Description & solution |
---|
Connected with controller: Blinking Red LED for 10 seconds, then turn Solid
Green Not connected with controller: Blinking Red LED for 10 seconds, then
turn Blinking Green| Lifter has reached a level limit. (The lifter reached its
highest or lowest setpoint)| Press the Down (or Up) button on the LRC-1 module
to lower(or raise) the unit(s) from the ned limit position.
If it’s not working, repair or RMA may be needed.
Blinking Red LED for 10 seconds, then turn Solid Green| Reached minimum level
(The lifter reached its lowest setpoint or the lowest level the hardware can
reach)| Press the up button on the LRC-1 module to raise the unit(s) above the
low limit position. If it’s not working, repair or RMA may be needed.
Blinking Red LED| Steel cable is loosened or has slacks. ‘There needs to be
some weight on the cable when lifting.| Lower the lifter slightly, then lift a
heavy object then lower it again to eliminate slack. If it’s not working,
repair or RMA may be needed.
Solid Red LED| System protection (Overloaded/ too much weight on the lifter )|
It should go back to normal operation in 60 seconds. Then test the lifter
without adding any weight to it. If this fixes the problem, it’s likely the
lifters have been temporarily overloaded. Please make sure to keep the weight
within the specified range.
| | If it’s still not working, repair or RMA may be needed.
Solid Red LED| Hardware malfunction| Repair or RMA may be needed.
DATA SIGNAL WIRING
The LLT-1 Smart Light Lifter can operate via its control panel as shown above. To expand the LLT-1 features, such as custom lifting range and synchronized multi-lifter control; the LRC-1 Smart Lifter Remote (sold separately) is required. Follow the diagram below for a recommended “multi-lifter” and “lifter-group” setup.
The LLT-1 communication cables are daisy-chained from one lifter to another. Up to 30 LLT-1 can be interconnected and paired with the LRC-1 remote. Using multiple LLT-1 connected together will provide an easily expandable synchronized light lifter control system.
Multiple LRC-1 remotes can connect to the HCS-2 Hydro Pro to utilize the
advanced features. Each LRC-1 is treated as a “lifter-group”, up to 50 LRC-1
can be connected to the HCS-2.
*Note:* A single LRC-1 remote can pair and control a signal chain of up to
30 LLT-1 lifters.
Note:** The HCS-2 maincontroller can pair and control up to 50 LRC-1
remote controls.
LIFTER SYSTEM INITIAL SETUP
An initial setup is needed when two or more lifters are used on the same light
fixtures. Follow the recommended setup instructions below to ensure the lifter
system is setup correctly.
Ensure you have properly calculated the weight of all components (unistrut,
lights, power cables etc.) the lifters will carry, and are within the rated
weight limit.
-
Install the light lifters to a secure location overhead. Connect the power cables to the LLT-1.
*Caution: Users are responsible to ensure all components that are connected to the Smart Light Lifter are rated properly and structurally sound. -
Using the LLT-l’s descend button to individually lower the lifter’s steel cable down to the same level. While manually lowering the cable on each lifter, apply a small amount of force, or attach a small weight to make sure the cable extends smoothly from the LLT-1.*Use a ruler or tape measure to ensure they are all equal distance from the LLT-1 body.
-
Connect the support system (e.g. unistrut) to the lifters’ steel cable loop, so that the lifter bears a light weight.
-
Ensure the support system (e.g. unistrut) is leveled and all lifters weight distribution is equal. If individual lifters need to be adjusted, use the ascent/descent buttons on the lifter.
*Caution: Users must address potential situations shown below before continuing the setup procedures. If one or more of the lifters are not all level, the lights may be lifted unevenly and/ or some lifters will not be bearing any weight. Manually use the up down buttons on each LLT-1 so that equal weight will be supported by each lifter.
Notice the middle steel cable is lose and not carrying any weight.
Notice the light support structure (unistrut) is not leveled. -
Daisy chain the lifters that need to be synchronized together by using the ECS-7 data cables.
-
Connect the LRC-1 Smart Lifter Remote to the first lifter and ECS-7.
-
Address the lifter and pair the remote by pressing the LLT-1’s ascend button once. When the lifter is paired with the remote, the lifter’s LED will turn from blinking green to soi Id green. Whille the LRC-1’s LED will turn from rapid blinking green (0.6s per blink) to slow blinking green (1.2s per blink). (Repeat this step until you pair all lifters in the chain. For more details on LRC-1, see P.16)
-
Test the synchronized ascent and descent via the LRC-1 Smart Lifter Remote to verify all lifters are paired and working with the remote.
Caution: Monitor all lifters’ operation. If any of the lifter(s) stopped working, let go of the ascend/descend button immediately and check and troubleshoot the lifter(s) error status. -
Install grow light into the support system (e.g. unistrut
-
Set the lifters’ upper and lower range limit via LRC-1 by ascend/ descend to the desired height levels, press and hold the Highest/ Lowest Range Setup Button until the LED indicator turns from blinking red to solid. (see P.18 for more details)
-
Connect the LRC-1 to the Hydro-X Pro (HCS-2) Main controller’s device line via ECS-9 Data cable.
-
Address and pair the remote with HCS-2 by pressing LRC-l’s Highest Range Setup Button once. When the remote is paired with the HCS-2, the remote LED will turn from slow blinking green(1.2s per blink) to solid green. A “Device Added” pop-up message will appear in HCS-2. (For more details on LRC-1, see P.16
-
With multiple LRC-1 remotes, you can create multiple “lifter-group”. Connect the LRC-1 remotes to the HCS-2 via SPH-1 splitter hub for advance features such as “synchronized lifter-group control”. (For more details, see Hydro-X Pro user manual and tutorial video.)
Smart Lifter Remote (LRC-1)
OVERVIEW
The LRC-1 Lifter Remote Control is designed to be used with the LLT-1 light lifter. Its’ plug & play easy installation enables users to easily install and operate the light lifter(s) from a distance, and program LLT-1 light lifters maximum and minimum range.
The LRC-1 LED indicator will also show its’ operation, program settings and
height limit for users easy reference.
The LRC-1 Lifter Remote can be connected with the Hydro-X Pro for advanced
features such as lifter-group control.
SPECIFICATION
Input Voltage and Amperage: | 12V.0.1A |
---|---|
Working Environments : | Temperature 32 -104°F / 0 -40°( Humid ity $90% |
Product Dimensions: | 5.12″ I 130mm(L) x 7.36″ / 187mm(W) x 3.46 ” / 88mm(H) |
Product Weight: | 0.661b s/0 .3kg |
INSTALLATION
Connect the longer jack on the LRC-1 directly to the Remote Controller Signal
Port on the LLT-1 light lifter if you are only using one lifter.
If you want to synchronize multi-lifter control with one LRC-1 remote, connect
the longer jack to a ECS-7 and daisy chain these lifters together (follow the
“Data Signal Wiring” guide on P.9).
Address and pair the connected remote and lifter by pressing the lifter’s
ascend button. If you are connecting the remote to a daisy-chained multi-
lifter, address and pair all lifters individually by pressing the ascend
button on the lifters. Connect the shorter cable to ECS-9, and use the ECS-9
RJ 12 port to connect the controller to Hydro-X Pro main controller. Address
and pair the remote with the HCS-2 by pressing LRC-l’s Highest Range Setup
Button once. When the remote is paired with the HCS-2, remote’s LED will turn
from slow blinking green(1.2s per blink) to solid green. A “Device Added” pop-
up message will appere in HCS-2.
*Note: A single remote can pair and control a signal chain up to 30 lifters.
OPERATION INSTRUCTIONS
- The LED indicator will be blinking green when the ascend or descend button is held.
- Once the highest or lowest setpoint is positioned, hold the highest or lowest range setup button on the LRC-1 for 3 seconds to lock the position in memory. The LED will blink red while saving the setting. When it turns to solid red, that means the position has been assigned and locked successfully.
- The highest range must be set higher than the lowest, and vice versa. The LED indicator will blink green for 5 seconds once it’s been sent, the remote shall only be able move the lights up or down within the setup range.
- The LED indicator will blink red for 5 seconds when the cable reaches the upper or lower range limit, and cannot go further. *Press the up or down button to move the lifter from the positioning limit. Reset Range Limit: Hold both the highest and lowest range setup buttons for 3 seconds.
Unpair Lifter(s) in signal chain: Hold both the highest range setup button and ascend button for 3 seconds. The LED indicator will be blinking red and green, the LED will be solid red after 3 seconds indicating the unit has been successfully un-paired.
The LED indicator will be blinking red and green, solid red after 3 seconds indicates successful range limit removal.
LED LIGHT INDICATOR
LED Light Indicator | Status |
---|---|
Solid Green LED | Normal operation status. The remote is connected and paired |
with both the lifter (s) and main controller .
Rapid Blinking Green LED (0.6s per blink)| Normal operation status. The remote
is not paired/ connected to both the lifter (s) and main controller.
or
Normal operation status. The remote is connected and paired to the main
controller, but not paired/connected to the lifter(s).
Slow Blinking Green LED (12s per blink)| Normal operation status.
The remote is connected and paired to the lifter(s), but not paired/connected to the main controller.
Blinking Red LED| One or more of the paired lifter(s) in the signal chain has an error/ offline. Check the LED indicator on the lifter(s) to troubleshoot (details on P.7).
*Note:* The blinking red indicator will turn green after 10 seconds. The
indicator will blink red for another 10 seconds if the error persists when the
user operates the LRC-1 controller.
Caution:** Always monitor all lifters’ operation when lifting or lowering
via the remote. (Especially when operating under synchronized multi-lifter
usage) If any of the lifter(s) stopped working, let go of the ascend/descend
button immediately. Check and troubleshoot the lifter(s) error status.
WARNING : DO NOT allow the Light Lifter System to be exposed to water or
excessive heat. DO NOT open or attempt to repair or disassemble the
controller, as there are no user-serviceable parts inside. Opening the
controller will void the warranty.
If the surface of the Light Lifter System is dirty, wipe it with a dry towel.
The Light Lifter System operates under natural ventilation conditions.
CUSTOMER SERVICES
you have any questions.please contact us:
TrolMaster Agro Instruments Co.,Ltd. 64 N Mission Dr, Pueblo West, (081007
May 2022 ©TrolMaster Manufactured by TrolMaster(XiaMen) Electronics Co., Ltd.
No.98-2, North Xinglin 2nd Road, Jimei District, XIAMEN, Fujian 361022
Powered by TrolMaster
www.thinkgrowled.com
support@thinkgrowled.com
ThinkGrow Smart Light Lifter (LLT-1)
Smart Lifter Remote (LRC-1)
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>