orlight ORL1009-F-HS Magnetic Downlight Range Instruction Manual

June 4, 2024
orlight

orlight LOGO MAGNETIC DOWNLIGHT RANGE
ORL1009-F-HS / ORL1009-F-HS-IP44 /
ORL1019-F-HS / ORL1019-F-HS-IP54

Installation instructions

ORL1009-F-HS Magnetic Downlight Range

ORL1009-F-HS / ORL1009-F-HS-IP44 / ORL1009-F-HS-S /ORL1009-IP44-F-HS-S/

orlight ORL1009 F HS Magnetic Downlight Range

ORL1019-F-HS / ORL1019-F-HS-S / ORL1019-F-HS-IP54

orlight ORL1009 F HS Magnetic Downlight Range - FIG

INSTALLATION

Or light does not recommend cutting holes prior to receipt of the product in hand.
Please see the reverse for full instructions. For further dimensions please refer to www.orlight.com.
We recommend that this product is installed by a competent person in accordance with the latest edition of the IET Wiring Regulations BS 7671 “Requirements for Electrical Installations” and the Buildings Regulations, as may be applicable subject to the location and country of the job or installation.
For more information and installation guidelines please refer to “Guide on Lighting Risks and Regulations” which can be downloaded from the website: http://www.orlight.com/resources/res/31/Orlight_guide_on_lighting_risks_3.pdf
**
1. Installation
Step 1 – Cut the aperture in the ceiling. We recommend that a sample hole is cut in some scrap material to familiarise yourself with the installation.
Step 2 – Allow the lighting cable to drop through the aperture. Connect mains cabling to the Terminal Block. Ensure all cables are neatly dressed away from any secondary heat sources.
Step 3 – Press the ceiling spring clips upwards so they lay against the body of the luminaire and then slot the luminaire into the aperture.
Step 4 – Restore the electricity and check the illumination.
2. Wiring:
Disconnect the mains supply before installation. Ensure that the unit is installed and maintained by a certified professional and that installation conforms to any local building control standard applicable.
a. For low voltage installation:
Connect the mains supply to the Or light transformer and the 12V supply from the Or light transformer to the terminal block provided. Insert the inner ring into its outer ring counterpart, which will consequently be held in place magnetically. The fixture may be rotated and tilted to direct light as required, depending on the fixture type chosen.
b. Mains installation:**
Connect the mains to the terminal block provided. Insert the lamp within the inner ring and connect it to the lamp holder. Insert the inner ring into its outer ring counterpart, which will consequently be held in place magnetically. The fixture may be rotated and tilted to direct light as required, depending on the fixture type chosen.

  • Please note, that all information contained within this instruction manual is provided in good faith. We will not be held responsible for any losses incurred as a result of any inaccuracies contained within this document.
    Please note: Standards are dependent on the fixture options.
    PLEASE OBSERVE MAXIMUM STANDARDS AS STATED ON FIXTURE SPECIFICATIONS.

www.orlight.com
01923 851 890

Documents / Resources

| orlight ORL1009-F-HS Magnetic Downlight Range [pdf] Instruction Manual
ORL1009-F-HS, ORL1009-F-HS-IP44, ORL1009-F-HS-S, ORL1009-IP44-F-HS-S, ORL1009-F-HS Magnetic Downlight Range, Magnetic Downlight Range, Downlight Range
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals