CCEI M12KCA Underwater LED Lighting User Manual
- June 12, 2024
- CCEI
Table of Contents
CCEI M12KCA Underwater LED Lighting
Product Information
The Mini BRIO M12CA is an underwater LED lighting projector designed to replace incandescent lighting in swimming pools. It is energy-efficient and helps reduce energy consumption.
Technical characteristics
- Dimensions: Installation Power supply Power consumed
- Weight: 0.5kg (1.1lb)
- Voltage: 12 V~ AC / Frequency: 50Hz/60Hz
- Cable length (Projector only): 4.6m (15ft)
- Cable length (Complete box): 15.2m (50ft)
- LED type: PK10R300 (M12), PK10R301 (M12K), PK10R302 (M12B)
- IP Rating: IP-68
- Max light stream: 866 lm max. (M12), 160 lm max. (M12B)
Dimensions | Ø 47 mm (1-11/16in) / length 84mm (3-5/16in) |
---|---|
Installation | Only in a threaded 1.5″ niche ref. PF10R191 or PF10R192 |
Power supply | Voltage: 12 V~ AC / Frequency: 50Hz/60Hz |
Power consumed | 14W |
__
__
Weight
| Cable lenght| Projector only| Complete box
4,6m (15ft)| 0,5kg (1,1lb)| 1,2kg (2,6lb)
15,2m (50ft)| 1,2kg (2,6lb)| 1,9kg (4,2lb)
30,4m (100ft)| 2,2kg (4,4lb)| 2,9kg (6,4lb)
__
__
__
__
LED type
| 3 monochrome power LEDs
PK10R300 (M12)| Cool White (~6000°K)
PK10R301 (M12K)| Warm White (~3000°K)
PK10R302 (M12B)| Blue
Risk group 1 (low risk) according to IEC62471:2006
IP Rating| IP-68
__
__
Max light stream
| PK10R300 (M12)| 866 lm max.
PK10R301 (M12K)| 866 lm max.
PK10R302 (M12B)| 160 lm max.
The projector must never be powered other than in water.
Description
BRIO Mini BRIO M12 LED projector are designed to replace incandescent lighting, to reduce your energy consumption and to light your swimming pool.
Warnings
This product must be installed by a licensed or certified electrician or a qualified pool professional in accordance with the current National Electrical Code (NEC), NFPA 70 or the Canadian Electrical Code (CEC), CSA C22.1. All applicable local installation codes and ordinances must also be adhered to. Improper installation will create an electrical hazard which could result in death or serious injury to pool users, installers or others due to electrical shock, and may also cause damage to power source. Always disconnect the power to the pool light at the circuit breaker before servicing the light. Failure to do so could result in death or serious injury to service person, pool users or others due to electrical shock.
For countries in compliance with International Electrotechnical Commission (IEC) regulatory standards: The light fixture must be installed by a licensed or certified electrician or a qualified pool service person, in accordance with current IEC 364-7-702 and all applicable local codes and ordinance. Improper installation will create an electrical hazard, which could result in death or serious injury to pool user, installer or other due to electrical shock and may also cause damage to the property.
Technical support
Website : www.ccei.ca / Phone : +1.514.649.7748
Before installing, operating, or using the Mini BRIO M12CA, please read the following instructions carefully:
Installation
Wall through installation
- Fiberglass pool: Prior to installing, drill a hole in the pool using a 60-mm (2 3/8-in) diameter cylinder saw. Connect the wall through to a 1.5 threaded coupling on the rear.
- Concrete pool: Assemble a pipe of sufficient length with a 1.5 threaded coupling onto the wall through before sealing the assembly.
- Concrete + liner pool: Assemble a pipe of sufficient length with a 1.5 threaded coupling onto the wall through before sealing it. Glue a first gasket before placing the liner.
- Panels + liner pool: Prior to installing, drill a hole in the pool using an 80-mm (3 1/8-in) diameter cylinder saw. Glue the first liner gasket before installing it. Connect the wall through to a pipe with a 1.5 threaded coupling on the rear.
Placement in a wall
BRIO Mini BRIO M12CA (& M12KCA, M12BCA) LED projectors must only be installed in a threaded 1.5 niche ref. PF10R191 or PF10R192. We recommend that installation is performed by a professional.
In wall through
- Pass the gasket and the projector cable through the wall passage up to the connection box.
- Push and screw the projector to the back.
- Use the provided tool to securely screw the projector.
Packaging Contents
- Mini BRIO M12 projector with
- Locking/unlocking tool
- 2xAWG18 cable: Depending model
- 4,6m (15ft)
- 15,2m (50ft)
- 30,4m (100ft)
- Wall through: Depending model
- Wall through PF10R191 for fiberglass or concrete pool (supplied with 2″ gasket + 2″ locknut)
- Wall through PF10R192 for liner pool (supplied with 2″ gasket + 2 liner gasket + 4 inox screws + liner flange + 2″ locknut)
- Projector / Wall through O-ring (D35xd3,5mm)
- Technical manual (this document)
Electrical Connections
Installing this product could expose you to an electric shock. We strongly
recom-mend that you use a qualified professional. An installation error could
put you at risk and irreversibly damage the product and the equipment
connected to it.
In compliance with the current National Electrical Code (NEC), underwater
light-ing must always be supplied with SELV (Safety Extra Low Voltage). Turn
off the power supply upstream before doing anything to the electrical
installation.
Risk of Electrical Shock. Connect only to a circuit protected by a ground-
fault circuit-interrupter (GFCI). If you cannot verify that the circuit is
protected by a GFCI, contact a qualified electrician.
THE LED LIGHT AND PLASTIC NICHE FORM A COMPLETE NON-MET-ALLIC LOW VOLTAGE LIGHTING SYSTEM. THIS CONFIGURATION DOES NOT REQUIRE BONDING OR GROUNDING WHEN POWERED BY A LISTED TRANSFORMER AND INSTALLED IN COMPLIANCE WITH THE CURRENT NATIONAL ELECTRIC CODE (NEC).
The electrical connection must be performed dry, in a sealed connection box whose cable glands must be tightened in order to avoid any water in- filtration.
Once startup and the operation tests are complete, it is recommended to drown the connection with a reusable soft hydrophobic insulating gel. (ref. CCEI PNSP0002)
The soft external cable of this lighting system cannot be replaced.
If this cable is damaged, the lighting system must be disposed of or returned
to the manufacturer for possible reconditioning.
Transformer Power
The transformer to be used must have a secondary voltage of 12V (12.5V
depending on the model). The power of the transformer must be in line with the
power of the projectors to be connected.
In any case, the sum of the powers of the projectors must remain below or
equal to the power of the transformer.
__
Transformer Power
| Max no. of Mini BRIO M12
---|---
50VA| 3
100VA| 7
300VA| 21
It is preferable to use power supplies from the same manufacturer.
A. Declaration of Conformity
The Company CCEI Inc. (Québec 1170122155) declares that the product Mini BRIO M12CA (& M12KCA, M12BCA) satisfies the safety and electromagnetic compatibility requirements of European directives 2006/95/EC and 2004/108/EC and is UL listed under file E471596.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>