SEALEVEL SIO4-104.485 PCI Serial Interface
Product Information
The SIO4-104.485, Item Number 3543, is a PC/104 module that provides four
RS-422/485 serial interface ports. It is designed using the XR16C554 UART,
which features a 16-byte FIFO. The board is compatible with the XR16C854 (SE’ option) and OX16C954 (
SN’ option) UARTs, which offer enhanced FIFOs (128-byte
transmit and receive). The OX16C954 also includes a flexible clock pre scalar,
9-bit protocol, and an isochronous mode.
RS-422 provides excellent communication for long-distance device connections up to 4000 ft., with high noise immunity and data integrity. RS-485 is optimized for “Multi-Drop” or “Party-line” operations, allowing data selection from multiple peripherals (up to 31 devices) connected on an RS-485 bus.
The SIO4-104.485 is compatible with various operating systems, including Windows 98/NT/ME/2000/XP, Linux, and DOS. It comes with the SeaCOM API (Application Programmer Interface), available as a Windows dynamic link library (DLL) and a Linux kernel module and library. The SeaCOM API offers high-level function calls, sample code, and utilities to simplify software development.
Other Sealevel PC104 Serial Interface Products:
- (Item Number 3550) Single Port RS-422/485
- (Item Number 3551) Single Port RS-232
- (Item Number 3502) Dual Port RS-232/422/485
- (Item Number 3540) Four Port RS-232/422/485
- (Item Number 3542) Four Port RS-232
- (Item Number 3544) Two Port RS-232 / Two Port 422/485
Product Usage Instructions
Before You Get Started
What’s Included:
The SIO4-104.485 is shipped with the following items. If any of these items
are missing or damaged, please contact Sealevel for replacement.
- Advisory Conventions:
- Warning: The highest level of importance used to stress a condition where damage could result in the product or the user suffering serious injury.
- Important: The middle level of importance used to highlight information that might not seem obvious or a situation that could cause the product to fail.
- Note: The lowest level of importance used to provide background information, additional tips, or other non-critical facts that will not affect the use of the product.
Optional Items:
Depending on your application, you may find the following optional items
useful with the SIO4-104.485. These items can be purchased from Sealevel’s
website (www.sealevel.com) or by calling their sales team at
864-843-4343.
- Cables Options:
- Terminates the SIO4-104.485’s 40-pin header to four DB9M connectors.
- (Number CA110/CA143) This combination of cables also terminates the SIO4-104.232’s 40-pin header to four DB9M connectors. The CA110 provides a bulkhead mountable DB37 Male connector, and the CA143 provides a DB37 to 4 DB9 male connectors via a 36-inch “Spider” cable.
- (CA222/TB10) This combination of cables also terminates the SIO4-104.485’s 40-pin header to four DB9M connectors via a bulkhead mountable terminal block assembly. It provides four DB9 male connectors that can easily be integrated into the Sealevel Systems Relio line of embedded I/O servers.
Introduction
The SIO4-104.485, Item Number 3543, is a PC/104 module that provides four, RS-422/485 serial interface ports. The board is designed using the XR16C554 UART, which provides a 16-byte FIFO.
- In addition to the standard XR16C554 UART, the XR16C854 (‘SE’ option) and the OX16C954 (‘SN’ option) are available. Both UARTS feature enhanced FIFOs (128 byte transmit and receive), and both maintain compatibility with the
- XR16C554. The OX16C954 additionally features a flexible clock prescalar (from 1 to 31.875), 9-bit protocol, and an isochronous mode.
- RS-422 provides excellent communications for long distance device connections up to 4000 ft., where noise immunity and high data integrity are essential.
- RS-485 is optimized for ‘Multi-Drop’ or ‘Party-line’ operations selecting data from multiple peripherals (as many as 31 devices can be connected on an RS-485 bus).
The SIO4-104.485 is designed to be used with a variety of Operating Systems including Windows 98/NT/ME/2000/XP, Linux, and DOS. The SeaCOM API (Application Programmer Interface) available for the SIO4-104.485 provides a variety of useful high-level function calls implemented as a Windows dynamic link library (DLL) and as a Linux kernel module and library. In addition to the API, SeaCOM includes sample code and utilities to simplify software development.
Other Sealevel PC104 Serial Interface Products
- ULTRA SIO-104 (Item Number 3550) – Single Port RS-422/485
- SIO-104 (Item Number 3551) – Single Port RS-232
- SIO.104+2 (Item Number 3502) – Dual Port RS-232/422/485
- C4-104.ULTRA (Item Number 3540) – Four Port RS-232/422/485
- SIO4-104.232 (Item Number 3542) – Four Port RS-232
- SIO4-104.2+2 (Item Number 3544) – Two Port RS-232 / Two Port 422/485
Before You Get Started
What’s Included
The SIO4-104.485 is shipped with the following items. If any of these items is missing or damaged, please contact Sealevel for replacement.
- SIO4-104.485 Adapter
Advisory Conventions
-
Warning
The highest level of importance used to stress a condition where damage could result to the product, or the user could suffer serious injury. -
Important
The middle level of importance used to highlight information that might not seem obvious or a situation that could cause the product to fail. -
Note
The lowest level of importance used to provide background information, additional tips, or other non-critical facts that will not affect the use of the product.
Optional Items
Depending upon your application, you are likely to find one or more of the
following items useful with the SIO4-104.485. All items can be purchased from
our website (www.sealevel.com) or by calling our sales team at
864-843-4343.
Cables Options
-
IDC 40 to (4) DB9 Male connectors, 8” in length – (Item Number CA228)
Terminates the SIO4-104.485’s 40-pin header to four DB9M connectors. -
DB37 Male to 6” IDC40 Ribbon Cable and (1) DB37 to (4) DB9 Males, 36” in length – (Item Number CA110/CA143)
This combination of cables also terminates the SIO4-104.232’s 40-pin header to four DB9M connectors. The CA110 provides a bulkhead mountable DB37 Male connector and the CA143 provides a DB37 to 4 DB9 male connectors via a 36-inch ‘Spider’ cable. -
IDC40 to 18” IDC40 Ribbon Cable and IDC40 to (4) DB9 Male Terminal Block – (Item Number CA222/TB10)
This combination of cables also terminates the SIO4-104.485’s 40-pin header to four DB9M connectors via a bulkhead mountable terminal block assembly. It provides four DB9 male connectors that can easily be integrated into the Sealevel Systems Relio line of embedded I/O servers. -
DB9 Male to DB9 Female Optomux adapter (Item Number DB103)
The DB103 is designed to convert a Sealevel DB9 Male connector to a pinout compatible with AC24AT and AC422AT Opto-22 ISA bus cards. This allows Optomux devices to be controlled from any Sealevel RS-422 board with a DB9 Male connector. -
DB9 Male to DB9 Male Sony 207M adapter cable (Item Number CA190)
This cable allows any Sealevel RS-422 adapter with a DB-9 to connect directly to a Sony (or compatible) 207M “9 Pin” connector.
Card Setup
Address Selection
The SIO4-104.485 occupies 16 consecutive I/O locations. The DIP-switch (SW1)
is used to set the base address for these locations and the IRQ mode options.
Be careful when selecting the base address as some selections conflict with
existing PC ports. The following table shows the addressing options available.
If different address options are required, please contact Sealevel Systems
Technical Support about a custom PAL option.
SW1- 1| SW1- 2| SW1- 3| Port 1| Port
2| Port 3| Port 4
---|---|---|---|---|---|---
Off| Off| On| 300| 310| 320| 330
Off| On| Off| 400| 410| 420| 430
Off| On| On| 500| 510| 520| 530
On| Off| Off| 600| 610| 620| 630
On| Off| On| 1500| 1510| 1520| 1530
On| On| Off| 3220| 3230| 3240| 3250
On| On| On| 4220| 4230| 4240| 4250
Interrupt Modes
- DIP-Switch positions ‘S’ and ‘M’ on switch SW1 selects the interrupt mode for each adapter.
- With the ‘S’ selected, the adapter is in a (S)hared interrupt mode, which allows more than one adapter to access a single IRQ.
- ‘M’ indicates the inclusion of a 1K-ohm pull-down resistor required on one adapter when sharing interrupts.
Set the switch to ‘S’ for shared interrupt mode on all adapters sharing an IRQ. On one of the adapters sharing an interrupt set the switches for both ‘S’ and for ‘M’. This provides the pull-down resistor circuit that makes sharing IRQs possible. If you are using more than one compatible adapter in a bus, you should only have one adapter set to ‘M’.
IRQ Selection
The SIO4-104.485 has an interrupt selection jumper, which should be set prior
to use, if an interrupt is required by your application software. Consult the
user manual for the application software being used to determine the proper
setting.
Clock Modes
The SIO4-104.485 utilizes a 14.7456 MHz oscillator. This is eight times faster
than the standard COM: port oscillator, which typically is 1.8432 MHz. This
allows the adapter to achieve a maximum data rate of 921.6Kbps. The following
sections outline the baud rate calculations and instructions for achieving
your desired baud rate.
Baud Rates and Oscillator value
The following table shows some common data rates and the rates you should
choose to achieve them when using the SIO4-104.485 . If the O/S of choice is
Windows 95/98/ME/2000/NT/XP, the oscillator value (14.7456 MHz) should be
entered into the ‘Advanced Tab’ on 95/98/Me/2000/XP Device Manager applet.
Typically this is done automatically when the Sealevel Software driver is
loaded. When using Windows NT, the ‘Advanced Ports’ applet in the Control
Panel should be launched and the oscillator value entered manually in the
‘Advanced’ tab, or all data rates will be eight (8) times the selected rate.
For example if a data rate of 19.2Kbps is selected, the actual data rate will
be 153.6Kbps.
When using any other OS (i.e. Linux, or QNX) the following table should be used.
For this Data Rate | Choose this Data Rate |
---|---|
1200 bps | 150 bps |
2400 bps | 300 bps |
4800 bps | 600 bps |
9600 bps | 1200 bps |
19.2K bps | 2400 bps |
57.6 K bps | 4800 bps |
115.2 K bps | 14.4K bps |
230.4K bps | 28.8K bps |
460.8K bps | 57.6 K bps |
921.6K bps | 115.2 K bps |
If your communications package allows the use of Baud rate divisors, choose the appropriate divisor from the following table:
For this Data Rate | Choose this Divisor |
---|---|
1200 bps | 768 |
2400 bps | 384 |
4800 bps | 192 |
9600 bps | 96 |
19.2K bps | 48 |
38.4K bps | 24 |
57.6K bps | 12 |
115.2K bps | 8 |
230.4K bps | 4 |
460.8K bps | 2 |
921.6K bps | 1 |
Electrical Interface Selection
Each of the ports on the SIO4-104.485 can be individually configured as
RS-422, or as a two-wire RS-485 interface. This is a software-selectable
feature and is found at Base+15. To enable a port for RS-422, simply write a
‘0’ to Base+15 (this is the power-up default). To enable a port for two-wire
RS-485 simply write a ‘1’ to Base+15. If the Sealevel Software Windows drivers
are used, this is accomplished as a function of the Device Manager.
RS-485 Enable
RS-485 is backwardly compatible with RS-422; however, it is optimized for
party line or multi-drop applications. The output of the RS-422/485 driver is
capable of being active (enabled) or tri-state (disabled). This capability
allows multiple PCs to be connected in a multi-drop bus and selectively
polled. Half-duplex two-wire operation is also possible by connecting TX+ to
RX+ and TX- to RX- in your cable hood. The enable to driver is connected to
the UART Request to Send (RTS) line for RS-485 communications. This allows the
RS-485 driver to be tri-stated when inactive on a multi-drop polled network.
The software that you are using must “know how” to enable the driver when it
is answering a poll. Failure to correctly utilize the enable can cause
transmitter contention problems preventing operation by any node on the
network. If the Sealevel Systems Windows Software driver is used, a ‘Radio’
style button on the ‘Advanced’ property page under the Device manager can be
selected that will automatically toggle RTS for use as an enable.
If the SIO4-104.485 is equipped with the optional 16C954, (Item Number 3543-SN) a hardware mode can be selected in the UART that will also enable the RS-485 drive automatically.
Line Termination
Typically, each end of the RS-485 bus must have line-terminating resistors
(RS-422 terminates at the receive end only). Typically a 120-ohm resistor is
across each RS-422/485 input in addition to a 1K-ohm pull-up/pull-down
combination that biases the receiver inputs. If multiple SIO4-104.485 adapters
are configured in an RS-485 network, only the boards on each end should have
the termination in place. Contact Sealevel Technical Support if you have
questions on how to remove this termination.
RS-485 ‘Echo’
The RS-485 ‘Echo’ is the result of connecting the receiver inputs to the
transmitter outputs. Every time a character is transmitted; it is also
received. The SIO4-104.485 automatically suppresses this ‘Echo’.
Software Installation
Windows Installation
- Do not install the Adapter in the machine until the software has been fully installed.
- Only users running Windows 7 or newer should utilize these instructions for accessing and installing the appropriate driver via Sealevel’s website. If you are utilizing an operating system prior to Windows 7, please contact Sealevel by calling 864.843.4343 or emailing support@sealevel.com to receive access to the proper driver download and installation instructions.
- Begin by locating, selecting, and installing the correct software from the website – SeaCOM software.
- Select the “SeaCOM for Windows” download link.
- The setup file will automatically detect the operating environment and install the proper components.
To confirm that the SeaCOM driver has been successfully installed, click on the ‘Start’ button, and then select ‘All Programs’. You should see the ‘SeaCOM’ program folder listed. You are now ready to proceed with connecting the 3543 to your system. Refer to the Hardware Installation section for details.
Linux Installation
- You MUST have “root” privileges to install the software and drivers.
- The syntax is case sensitive.
SeaCOM for Linux can be downloaded here: https://www.sealevel.com/support /software-seacom-linux/. It includes the README and the Serial-HOWTO help files (located at seacom/dox/howto). This series of files both explains typical Linux serial implementations and informs the user about Linux syntax and preferred practices.
- User can use a program such as 7-Zip to extract the tar.gz file.
In addition, the software selectable interface settings can be accessed by referencing seacom/utilities/3543mode.~
3rd Party Software Support
Third party software support for many HMI/MMI and other process control
software is accessible through links on the Sealevel’s website. For the most
up to date information on third party software support, please visit:
https://www.sealevel.com/support/3rd-party-software-support/.
For additional software support, including QNX, please call Sealevel Systems’ Technical Support, 864-843-4343. Our technical support is free and available from 8:00 AM – 5:00 PM Eastern Time, Monday through Friday. For email support contact: support@sealevel.com.
Physical Installation
Extreme care should be taken when installing the SIO4-104.485 to avoid causing damage to the connectors. After the adapter is installed, connect your I/O cable to P4. Refer to Card Setup for information on setting the address and jumper options before inserting the SIO4-104.485 onto the stack.
- Do not install the Adapter in the machine until the software has been fully installed.
- Turn off PC power. Disconnect the power cord.
- Remove the case cover (if applicable).
- Gently insert the SIO4-104.485 connector noting proper key orientation of the expansion connector on a PC/104 compatible card. The SIO4-104.485 adapter is keyed per the current PC/104 Specification. This will aid in preventing the adapter from being inserted incorrectly.
- Mounting hardware (nylon stand-offs and screws) is provided to ensure a good mechanical connection. Retain any mounting hardware not used to allow for future expansion.
- Replace the cover.
- Connect the power cord and power up the machine.
The SIO4-104.485 is now ready for use.
Physical Connection
The port signals for the SIO4-104.485 are physically connected via a 40-pin
box header.
The following table shows connector P4’s pin-out.
Port| P4| Signal Name RS-422| Signal Name
RS-485
---|---|---|---
4
| 1| RX4+| DATA4+
3| RX4 –| DATA4-
5| TD4 –|
7| TD4+|
9| GND4| GND4
3
| 10| GND3| GND3
12| TD3+|
14| TD3-|
16| RX3-| DATA3-
18| RX3+| DATA3+
2
| 19| RX2+| DATA2+
21| RX2-| DATA2-
23| TD2-|
25| TD2+|
27| GND2| GND2
1
| 28| GND1| GND1
30| TD1+|
32| TD1-|
34| RX1-| DATA1-
36| RX1+| DATA1+
All pins not listed are no contacts.
Available for use with the SIO4-104.485 are the CA228, the CA110/CA143, and the CA222/TB10 combination cables. These cables terminate the SIO4-104.485 40-pin header to four DB9M connectors. This termination provides the standard DB9 pin out for RS-232 (EIA/TIA574) in RS-232 mode. The following table illustrates the DB9 pin out when using any of these optional cables.
RS-422
Signal | Name | Pin # | Mode |
---|---|---|---|
GND | Ground | 5 | |
TX+ | Transmit Data Positive | 4 | Output |
TX- | Transmit Data Negative | 3 | Output |
RX+ | Receive Data Positive | 1 | Input |
RX- | Receive Data Negative | 2 | Input |
RS-485
Signal | Name | Pin # | Mode |
---|---|---|---|
GND | Ground | 5 | |
DATA+ | Receive Data Positive | 1 | I/O |
DATA- | Receive Data Negative | 2 | I/O |
Please terminate any control signals that are not being used. The most common way to do this is connect RTS to CTS and RI. Also, connect DCD to DTR and DSR. Terminating these pins, if not used, will help ensure you get the best performance from your adapter.
Electrical Characteristics
Specifications
RS-422/485 Transceiver
- Bidirectional Transceiver
- Meet or Exceed the Requirements of ANSI Standards TIA/EIA-422-B and TIA/EIA-485-A and ITU Recommendations V.11 and X.27
- Designed for Multipoint Transmission on Long Bus Lines in Noisy Environments
- 3-State Driver and Receiver Outputs
- Individual Driver and Receiver Enables
- Wide Positive and Negative Input/Output Bus Voltage Ranges
- Driver Output Capability . . . ±60 mA Max
- Thermal Shutdown Protection
- Driver Positive and Negative Current Limiting
- Receiver Input Impedance . . . 12 k Min
- Receiver Input Sensitivity . . . ±200 mV
- Receiver Input Hysteresis . . . 50 mV Typ
- Operate From Single 5-V Supply
Temperature Range
Operating:| 0°C – 70°C
Storage:| -50°C – 105°C
Power Requirements
Supply line| +5 VDC
Rating| 794 mA
Physical Dimensions
Board Length:| 3.550 inches (9.017 cm)
Board Height:| 3.775 inches (9.589 cm)
Troubleshooting
The adapter should provide years of trouble-free service. However, in the event that device appears to not be functioning incorrectly, the following tips can eliminate most common problems without the need to call Technical Support.
- Install software first. After installing the software then proceed to Physical Installation section of the manual.
- Identify all I/O adapters currently installed in your system. This includes your on-board serial ports, controller cards, sound cards etc. The I/O addresses used by these adapters, as well as the IRQ (if any) should be identified.
- Configure your Sealevel Systems adapter so that there is no conflict with currently installed adapters. No two adapters can occupy the same I/O address.
- Try the Sealevel Systems adapter with a unique IRQ. While the Sealevel Systems adapter does allow the sharing of IRQs, many other adapters (i.e., SCSI adapters & on-board serial ports) do not.
- Make sure the Sealevel Systems adapter is securely installed.
- For Windows operating systems, the diagnostic tool ‘WinSSD’ is installed in the SeaCOM folder on the Start Menu during the setup process. First find the ports using the Device Manager, the use ‘WinSSD’ to verify that the ports are functional.
- Always use the Sealevel Systems diagnostic software when troubleshooting a problem. This will help eliminate any software issues and identify any hardware conflicts.
If these steps do not solve your problem, please call Sealevel Systems’ Technical Support, 864-843-4343. Our technical support is free and available from 8:00 A.M.- 5:00 P.M., Eastern Time Monday through Friday. For email support contact support@sealevel.com.
How To Get Assistance
Please refer to Troubleshooting Guide prior to calling Technical Support.
- Begin by reading through the Trouble Shooting Guide in Appendix A. If assistance is still needed, please see below.
- When calling for technical assistance, please have your user manual and current adapter settings. If possible, please have the adapter installed in a computer ready to run diagnostics.
- Sealevel Systems provides an FAQ section on its web site. Please refer to this to answer many common questions. This section can be found at http://www.sealevel.com/faq.asp.
- Sealevel Systems maintains a web page on the Internet. Our home page address is www.sealevel.com. The latest software updates, and newest manuals are available via our website.
- Technical support is available Monday to Friday from 8:00 A.M. to 5:00 P.M. Eastern Time. Technical support can be reached at 864-843-4343. For email support contact support@sealevel.com.
RETURN AUTHORIZATION MUST BE OBTAINED FROM SEALEVEL SYSTEMS BEFORE RETURNED MERCHANDISE WILL BE ACCEPTED. AUTHORIZATION CAN BE OBTAINED BY CALLING SEALEVEL SYSTEMS AND REQUESTING A RETURN MERCHANDISE AUTHORIZATION (RMA) NUMBER.
Electrical Interface
RS-422
The RS-422 specification defines the electrical characteristics of balanced
voltage digital interface circuits. RS-422 is a differential interface that
defines voltage levels and driver/receiver electrical specifications. On a
differential interface, logic levels are defined by the difference in voltage
between a pair of outputs or inputs. In contrast, a single-ended interface,
for example RS-232, defines the logic levels as the difference in voltage
between a single signal and a common ground connection. Differential
interfaces are typically more immune to noise or voltage spikes that may occur
on communication lines. Differential interfaces also have greater drive
capabilities that allow for longer cable lengths. RS-422 is rated up to 10
Megabits per second and can have cabling 4000 feet long. RS-422 also defines
driver and receiver electrical characteristics that will allow 1 driver and up
to 32 receivers on the line at once. RS-422 signal levels range from 0 to +5
volts. RS-422 does not define a physical connector.
RS-485
RS-485 is backwardly compatible with RS-422; however, it is optimized for
party line or multi-drop applications. The output of the RS-422/485 driver is
capable of being Active (enabled) or Tri-State (disabled). This capability
allows multiple ports to be connected in a multi-drop bus and selectively
polled. RS-485 allows cable lengths up to 4000 feet and data rates up to 10
Megabits per second. The signal levels for RS-485 are the same as those
defined by RS-422. RS-485 has electrical characteristics that allow for 32
drivers and 32 receivers to be connected to one line. This interface is ideal
for multi-drop or network environments. RS-485 tri-state driver (not dual-
state) will allow the electrical presence of the driver to be removed from the
line. Only one driver may be active at a time and the other driver(s) must be
tri-stated. RS-485 can be cabled in two ways, two-wire and four-wire mode. The
two-wire mode does not allow for full duplex communication and requires that
data be transferred in only one direction at a time. For half-duplex
operation, the two transmit pins should be connected to the two receive pins
(Tx+ to Rx+ and Tx- to Rx-). Four-wire mode allows full duplex data transfers.
RS-485 does not define a connector pin-out or a set of modem control signals.
RS-485 does not define a physical connector.
Asynchronous Communications
Serial data communications implies that individual bits of a character are transmitted consecutively to a receiver that assembles the bits back into a character. Data rate, error checking, handshaking, and character framing (start/stop bits) are pre-defined and must correspond at both the transmitting and receiving ends.
Asynchronous communications is the standard means of serial data communication for PC compatibles and PS/2 computers. The original PC was equipped with a communication or COM: port that was designed around an 8250 Universal Asynchronous Receiver Transmitter (UART). This device allows asynchronous serial data to be transferred through a simple and straightforward programming interface. A start bit, followed by a pre-defined number of data bits (5, 6, 7, or 8) defines character boundaries for asynchronous communications. The end of the character is defined by the transmission of a pre-defined number of stop bits (usually 1, 1.5 or 2). An extra bit used for error detection is often appended before the stop bits.
This special bit is called the parity bit. Parity is a simple method of determining if a data bit has been lost or corrupted during transmission. There are several methods for implementing a parity check to guard against data corruption. Common methods are called (E)ven Parity or (O)dd Parity. Sometimes parity is not used to detect errors on the data stream. This is referred to as (N)o parity. Because each bit in asynchronous communications is sent consecutively, it is easy to generalize asynchronous communications by stating that each character is wrapped (framed) by pre-defined bits to mark the beginning and end of the serial transmission of the character. The data rate and communication parameters for asynchronous communications have to be the same at both the transmitting and receiving ends. The communication parameters are baud rate, parity, number of data bits per character, and stop bits (i.e.,9600,N,8,1).
Silk Screen – 3543 PCB
Warranty
Sealevel’s commitment to providing the best I/O solutions is reflected in the Lifetime Warranty that is standard on all Sealevel-manufactured I/O products. We are able to offer this warranty due to our control of manufacturing quality and the historically high reliability of our products in the field. Sealevel products are designed and manufactured at its Liberty, South Carolina facility, allowing direct control over product development, production, burn- in and testing. Sealevel achieved ISO-9001:2015 certification in 2018.
Warranty Policy
Sealevel Systems, Inc. (hereafter “Sealevel”) warrants that the Product shall
conform to and perform in accordance with published technical specifications
and shall be free of defects in materials and workmanship for the warranty
period. In the event of failure, Sealevel will repair or replace the product
at Sealevel’s sole discretion. Failures resulting from misapplication or
misuse of the Product, failure to adhere to any specifications or
instructions, or failure resulting from neglect, abuse, accidents, or acts of
nature are not covered under this warranty.
Warranty service may be obtained by delivering the Product to Sealevel and providing proof of purchase. Customer agrees to ensure the Product or assume the risk of loss or damage in transit, to prepay shipping charges to Sealevel, and to use the original shipping container or equivalent. Warranty is valid only for original purchaser and is not transferable. This warranty applies to Sealevel manufactured Product. Product purchased through Sealevel but manufactured by a third party will retain the original manufacturer’s warranty.
Non-Warranty Repair/Retest
Products returned due to damage or misuse and Products retested with no
problem found are subject to repair/retest charges. A purchase order or credit
card number and authorization must be in an RMA (Return Merchandise
Authorization) number prior to returning Product.
How to obtain an RMA (Return Merchandise Authorization)
If you need to return a product for warranty or non-warranty repair, you must
first obtain an RMA number. Please contact Sealevel Systems, Inc. Technical
Support for assistance:
- Available Monday – Friday, 8:00 AM to 5:00 PM EST
- Phone 864-843-4343
- Email support@sealevel.com.
Trademarks
Sealevel Systems, Incorporated acknowledges that all trademarks referenced in
this manual are the service mark, trademark, or registered trademark of the
respective company.
© Sealevel Systems, Inc.
References
- Sealevel - I/O & Computing Products, Engineering and Manufacturing
- Software: SeaCOM - Linux - Sealevel
- Software: SeaCOM - Windows - Sealevel