Therma-Stor 4042275 Oasis Dehumidifier Outlet Duct Kit Instruction Manual
- June 12, 2024
- Therma-Stor
Table of Contents
Therma-Stor 4042275 Oasis Dehumidifier Outlet Duct Kit
Product Information
The product is a duct kit (Part No. 4042275) designed for use dehumidifier.
It includes the following parts:
- Supply Duct Plenum
- Packed Fasteners (x4)
The tools required for installation are
- Portable Drill
- T25 Torx Driver
- 5/16 Hex Driver
Product Usage Instructions
- Before installing the duct kit, make sure to disconnect the dehumidifier from the electrical power and disconnect any previously installed ductwork.
- Using the T25 Torx Driver, unthread the #10-24 screws on the top panel (x1), rear panel (x1), and left panel (x2) halfway.
- Install the supply duct plenum on the dehumidifier by slotting the half-threaded screws into the keyed grooves (x4). Make sure the screws are pushed all the way into the grooves.
- Using the T25 Torx Driver, tighten the #10-24 screws on the top panel (x1), rear panel (x1), and left panel (x2) to securely fasten them.
- Locate the packed fasteners and using the 5/16 Hex Driver, drill the fasteners (x2) through the bottom holes of the supply duct plenum into the plastic base. Ensure the screws are securely fastened.
Note : The packed fasteners are self-drilling, so there is no need for pilot holes. The packed parts include two additional fasteners that are unneeded for the installation.
Parts Included
- Supply Duct Plenum
- Packed Fasteners (x4)
Tools Required
- Portable Drill
- T25 Torx Driver
- 5/16″ Hex Driver
CAUTION! Before installing the duct kit, disconnect the dehumidifier from the electrical power and disconnect the ductwork if previously installed.
Step 1: Using T25 Torx Driver, unthread #10-24 screws on the top panel (x1), rear panel (x1), and left panel (x2) halfway.
Step 2: Install the supply duct plenum on the dehumidifier by slotting half-threaded screws in the keyed grooves (x4). Ensure screws are pushed all the way into the grooves.
Step 3: Using T25 Torx Driver, tighten #10-24 screws on the top panel (x1), rear panel (x1), and left panel (x2). Ensure screws are securely fastened.
Step 4: Locate packed fasteners. Using a 5/16” Hex Driver, drill fasteners (x2) through the bottom holes of the supply duct plenum into a plastic base. Ensure screws are securely fastened.
Note: Packed fasteners are self-drilling. No need for pilot holes. Packed
parts have x2 additional fasteners that are unneeded.4201 Lien Rd Madison, WI
53704 TOLL-FREE 1-800-533-7533
www.thermastor.com
sales@thermastor.com
TS-1185 10/22 Rev A