The product is a duct kit (Part No. 4042275) designed for use dehumidifier. It includes the following parts:

  1. Supply Duct Plenum
  2. Packed Fasteners (x4)

The tools required for installation are

  1. Portable Drill
  2. T25 Torx Driver
  3. 5/16 Hex Driver

Product Usage Instructions

  1. Before installing the duct kit, make sure to disconnect the dehumidifier from the electrical power and disconnect any previously installed ductwork.
  2. Using the T25 Torx Driver, unthread the #10-24 screws on the top panel (x1), rear panel (x1), and left panel (x2) halfway.
  3. Install the supply duct plenum on the dehumidifier by slotting the half-threaded screws into the keyed grooves (x4). Make sure the screws are pushed all the way into the grooves.
  4. Using the T25 Torx Driver, tighten the #10-24 screws on the top panel (x1), rear panel (x1), and left panel (x2) to securely fasten them.
  5. Locate the packed fasteners and using the 5/16 Hex Driver, drill the fasteners (x2) through the bottom holes of the supply duct plenum into the plastic base. Ensure the screws are securely fastened.

Note : The packed fasteners are self-drilling, so there is no need for pilot holes. The packed parts include two additional fasteners that are unneeded for the installation.

Parts Included

  1. Supply Duct Plenum
  2. Packed Fasteners (x4)

Tools Required

  1. Portable Drill
  2. T25 Torx Driver
  3. 5/16″ Hex Driver

CAUTION! Before installing the duct kit, disconnect the dehumidifier from the electrical power and disconnect the ductwork if previously installed.

Step 1: Using T25 Torx Driver, unthread #10-24 screws on the top panel (x1), rear panel (x1), and left panel (x2) halfway.

Step 2: Install the supply duct plenum on the dehumidifier by slotting half-threaded screws in the keyed grooves (x4). Ensure screws are pushed all the way into the grooves.

Step 3: Using T25 Torx Driver, tighten #10-24 screws on the top panel (x1), rear panel (x1), and left panel (x2). Ensure screws are securely fastened.

Step 4: Locate packed fasteners. Using a 5/16” Hex Driver, drill fasteners (x2) through the bottom holes of the supply duct plenum into a plastic base. Ensure screws are securely fastened.

Note: Packed fasteners are self-drilling. No need for pilot holes. Packed parts have x2 additional fasteners that are unneeded.4201 Lien Rd Madison, WI 53704  TOLL-FREE 1-800-533-7533 www.thermastor.com sales@thermastor.com
TS-1185 10/22 Rev A

References