Smeg KSGT64X Integrated Hood User Manual
- June 12, 2024
- Smeg
Table of Contents
Smeg KSGT64X Integrated Hood User Manual
Instructions for use
CONTROL UNIT
optimal and efficient use of the product, it is recommended that you switch on the hood a few minutes before you start cooking and keep it on for at least 15 minutes after you have finished or until the steam and odours have been completely eliminated The following types of controls can be found on the front of the hood.
Instructions for use
Button functions
- Hood OFF button. (If the fan and the lights are on).
- Speed 1 button. Lights up when the motor is running at speed 1.
- Speed 2 button. Lights up when the motor is running at speed 2.
- Speed 3 button. Lights up when the motor is running at speed 3.
Turbo speed button. Lights up when the motor is running at speed 4. The motor switches from speed 4 to speed 3 after about 7 minutes. When the Turbo function is active, the button flashes and the timer function is not active.
- Lights On/Off button. Illuminated when the light is on.
- Pressing these buttons twice activates the timer.
- The timer function can only be activated when the fan motor is on.
- Once activated, a 10-minute timer starts, when the time elapses, the motor stops and the light switches off.
- The button flashes during this time. The timer can be canceled by touching the same button.
Light brightness adjustment
Briefly touching the button immediately switches the lights on or off.
Touching and holding this button for more than 1 second gradually increases
the brightness to the maximum level and then decreases it to the minimum level
as long as the button is pressed. Release the button once you have obtained
the required brightness. This level of brightness will be saved in the non-
volatile memory so that it will be set each time the light is switched on by
tapping the button once. Tapping the light button twice when the light is off
will set it to maximum brightness. It is factory set to maximum brightness.
Filter alarm reset
After 100 hours of hood operation, buttons, 1,2, and 3 will start to flash to
remind you to clean the filters. To reset this warning, press the On/Off
button for 5 seconds, the light of the On/Off button will flash once to
indicate that the filter time has been reset.
24hair exchange function
The 24h air exchange function allows you to clean the air in the room. To
start the 24-hour function, 1 press and hold the button for 3 seconds. The
extraction hood will run at a minimum speed for 10 minutes every hour (up to a
maximum of 24 hours). The buttons will flash as long as the function is
active. Briefly touching any button (apart from the button) will disable the
function.
9-button control panel
- Shutdown timer
- Speed selection
- Turbo function
- 24hair exchange function
- Automatic switch-off
- Filter alarm reset
- Light brightness adjustment
Light colour temperature adjustment Hob and hood connection
Touch Technology
The unit uses capacitive sensors to detect the touch of the button on the
front glass panel.
Lighting
When power is turned on, the unit will be in the off mode. Only the button is
illuminated (low brightness). After touching the button, the unit will go into
Stand-By mode and all buttons will be dimly lit. In Stand-by mode, the user
can activate any function that is allowed by the operating logic. The button
of the active function will be brightly lit.
Button functions
Hood OFF button. (If the fan and the lights are on)
- Speed 1 button. Lights up when the motor is running at speed 1.
- Speed 2 button. Lights up when the motor is running at speed 2.
- Speed 3 button. Lights up when the motor is running at speed 3.
- Turbo speed button. Lights up when the motor is running at speed 4.
- The motor switches from speed 4 to speed 3 after about 7 minutes. When the Turbo function is active, the button flashes and the timer function is not active.
24 hair exchange function button
Lights up when the motor is running at speed 1. Briefly touching activates
motor speed one and extracts air for 10 minutes every hour for 24 hours. Press
the button again to disable it. Automatic switch-off button. The button is
illuminated while the fan is in operation at the selected speed (1-2-3).
Briefly touching activates the automatic switch-off delay of 15 minutes.
Suitable for eliminating residual odours. It can be activated at fan speeds 1,
2 or 3. It is disabled by pressing the button or by switching off the fan.
Filter alarm reset button. The alarm is activated after 100 hours of actual
hood operation. When the filter alarm is on, pressing the button for about 3
seconds resets the alarm. If there is no filter alarm, pressing the button has
no effect (apart from the light colour temperature adjustment function below).
Before resetting the alarm signal, the activated charcoal filters have to be
replaced and the metal grease filters should be cleaned. Lights On/Off button.
Illuminated when the light is on. Pressing these buttons twice activates the
timer. The timer function can only be activated when the fan motor is on. Once
activated, a 10-minute timer starts, when the time elapses, the motor stops
and the light switches off. The button flashes during this time. The timer can
be cancelled by touching the same button.
Light brightness adjustment
Briefly touching the button immediately switches the lights on or off.
Touching and holding this button for more than 1 second gradually increases
the brightness to the maximum level and then decreases it to the minimum level
as long as the button is pressed. Release the button once you have obtained
the required brightness. This level of brightness will be saved in the non-
volatile memory so that it will be set each time the light is switched on by
tapping the button once. Tapping the light button twice when the light is off
will set it to maximum brightness. It is factory set to maximum brightness.
Light colour temperature adjustment
Touch again, touch and hold the button for at least 1 second to activate the
light colour temperature adjustment function. The temperature of the light
changes gradually and circularly from cold to warm. Release the button once
the required colour temperature has been obtained. This colour temperature
will be saved in the non-volatile memory so that it will be used each time the
light is switched on by tapping the button once.
GHOST function
When this product is turned off, only the button remains illuminated (at low
brightness). If the button is pressed, the hood will be set to standby and all
buttons will light up with a brightness of 5%. When on standby, if a function
is activated, the relative button will light up with 100% brightness. If you
press the button, the hood returns to standby mode and all buttons will light
up with a brightness of 5%.
Filter alarm reset
After 100 hours of hood operation, buttons,1 ,2 ,3 will start to flash to
remind you to clean the filters. To reset this warning, press the On/Off
button for 5 seconds, the light of the On/Off button will flash once to
indicate that the filter time has been reset.
24hair exchange function
The 24h air exchange function allows you to clean the air in the room. To
start the 24-hour function, press and hold the button for 3 seconds. The
extraction hood will run at a minimum speed for 10 minutes every hour (up to a
maximum of 24 hours). The buttons will flash as long as the function is
active. Briefly touching any button (apart from the button) will disable the
function.
Hob and hood connection Automatic operation specifications – Auto-Vent
2.0
Some models are provided with a wireless communication system to allow them to
be controlled automatically via an induction hob.
Automatic switch-on
When the hob is switched on, the hood switches on if it is in STANDBY mode
(all buttons illuminated at low brightness).
Operation in automatic mode
The automatic mode of operation is shown on the hood user interface as
follows. For example, if the fan motor is operating at speed 2 and the
appliance is in automatic mode:
Automatic switch-off
When the hob is switched off, the hood switches to STANDBY mode (all buttons
illuminated at low brightness).
Hob and hood connection Automatic/manual operation
If the hood is operating in automatic mode and the customer changes some hood
parameters via the user interface, automatic mode will be disabled and the
hood will no longer respond to the Auto-Vent 2.0 command from the hob. To re-
enable automatic mode, the hood first has to be set to OFF and then to STANDBY
mode.
CONTROLS ON THE REMOTE CONTROL
ON-OFF BUTTON: Press this button to enter Stand-By Mode while the device is already in Off Mode. Then, all buttons are illuminated in a low-brightness manner. Press this button again to turn back to the Off Mode, while the device is in Stand-By Mode or any Active Mode.
LAMP ON-OFF BUTTON: Press this button to turn on or turn off the lamp quickly. Pressing the Lamp On-OAff Button twice as the lamp is OFF, will turn on the lamp in maximum brightness.
24H BUTTON: Pressing this button activates the motor at the first speed and allows extraction for 10 minutes every hour for 24 hours. Press this button again to disable the function.
MINUS BUTTON: Pressing this button decreases the fan speed of the device until it reaches speed1.
PLUS BUTTON: Pressing this button increases the fan speed of the device until it reaches speed4 (Boost Speed).
DELAY FUNCTION: Pressing this button activates the automatic shutdown delay of 10 minutes. This function can only be activated at speeds 1, 2 or 3. You can disable this function by pressing this button again while the function is already active.
LAMP DIMMING: Pressing and holding this button starts gradually increasing the light level up to the maximum and then, decreasing down to the minimum level in a repeating manner, as long as the button is hold touched. When the desired light level is obtained, please release the button. Then, this light level will be recorded in nonvolatile memory, so that every time the lamp is turned on, this light level will be valid. (To activate this functionality, you have to turn on the lamp first)
TUNABLE WHITE: Pressing and holding this button activates tunable white functionality. The light temperature gradually changes from cold to warm and comes back in a repeated manner. When the desired light temperature is obtained, please release the button. Then, this light temperature will be recorded in nonvolatile memory, so that every time the lamp is turned on, this light temperature will be valid. (To activate this functionality, you have to turn on the lamp first)
Download PDF:Smeg KSGT64X Integrated Hood User Manual
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>