PlumbNation HMAC-600A Ultra 3 Inlet Macerator Pump Installation Guide

June 12, 2024
PlumbNation

PlumbNation HMAC-600A Ultra 3 Inlet Macerator Pump Installation Guide
PlumbNation HMAC-600A Ultra 3 Inlet Macerator Pump

Installation Requirements

Electrics: The unit must be installed to comply with current UK electrical regulations, with a fused spur rated at 3 amps. We advise that this is done by a registered electrician.

This appliance must be earthed. If the supply cord is damaged, it must be replaced by a qualified person. The cable type is H05VV-F, 3G0.75mm2 VDE. The IP rating of this appliance is IP55.

Water: The unit is designed for a horizontal toilet outlet with the standard European 18cm to the outlet centre from the floor. All other inlets must be gravity fed into the unit. The outlet comes as standard with a 32mm connection however 22mm can be used with a reducer. If using bends in the connecting pipe work ensure they are smooth curves to avoid blockages.

Specification: Water temperature should be a minimum of 1°C it is important that the unit does not freeze, and a maximum of 40 °C. Maximum vertical discharge 9.5 m. Maximum horizontal discharge 60m.

Inputs

The macerator can be used with multiple inputs, or just one. Blanking plates are provided to help you.

Installation

**The electrical installation of this product must be done by qualified persons only.

**

This macerator is only for use with a toilet using a horizontal outlet. The toilet must also have a flushing tank or tap. Note: the horizontal outlet must be 18cm above floor level in accordance with EU standards.

Discharge pipe length to the first elbow must be a minimum length of 0.5m.

Toilet Only Configuration

Toilet Only Configuration

  • Place this horizontal toilet outlet into the macerator, and clamp the rubber sleeve of the macerator around the pipe using the supplied jubilee clip.
  • Repeat for the 32mm or 40mm discharge pipe.

Configuration with Other Appliances

Configuration

Connect the discharge pipes of each appliance to the rubber connectors provided and clamp with supplied jubilee clamps.

For use with a bath or shower, there must be a gradient of 1cm per metre or greater. If used with a shower, a second check valve must be used. This must be fitted between the macerator and the tray. If other appliances are fitted along the discharge line, check valves must also be used on these.

Prior to first use flush a large quantity of clean water through the unit.

General Care and Maintenance

Daily Usage:

  • This product is suitable for indoor use only.
  • Do not put foreign objects, such as but not limited to condoms, sanitary towels, and wet wipes through the system as this will cause damage to theunit, and will invalidate your warranty.

Servicing:

  • Service and cleaning should be performed once every 6 months. It is recommended that this is done by a professional.
  • Before servicing, ensure the electric supply is off.
  • Appropriate PPE must be used whilst servicing the unit.

Warranty

Please note the following situations that will invalidate the warranty:

  • Failure to install the appliance in accordance with this installation guide.
  • Installation by unqualified persons.
  • Foreign objects in the system.
  • Failure to carry out regular servicing/maintenance as detailed in this guide.

Product Disposal

This product should not be disposed of with other household wastes. To prevent possible harm to the environment or human health from uncontrolled waste disposal, the unit should be disposed of at an appropriate local authority facility

The symbol on the appliance states that it meets the new directive (2012/19/EU) and must be handled in accordance with this standard at the end of its service life.

Trouble Shooting

Symptom Cause Resolution
The macerator has cut out
The device has overheated. Leave the unit to cool for 30 mins, switch it back

on and hold the override switch to reset the unit. Check for blockages.
The macerator has cut out| Power supply has been interrupted| Check fuses and power supply.
The water is back flowing| Insufficient gradient| Ensure a gradient of 1cm permeter is used.
The unit is leaking.| Check valve/jubilee clips are not fitted correctly.| Check these items.
The macerator is non- operational and has never been opened.| The macerator is connected to an incorrect size pipe.| Ensure the pipe is 32 or 40mm.
The electrical install wasincorrect.| Ensure the device was installedby a qualified person.
The check valve is facing in the wrong direction.| Check the check valve(s).
Pressure switch is blocked| Check/replace the pressure switch.
The macerator is not powerful enough.| Discharge pipes are toolong/high| Check the distances against thespec.
Discharge pipe is to small| Check the sizes
Unit is blocked.| Service as per instructions above.
The macerator emits a humming noise but does not discharge waste.| Pump is blocked| Check/service pump.
Check valve is installed the wrong way round.| Check the check valve.
The macerator discharges waste with no demand.| Check valve is faulty| Examine/replace the checkvalve.
The tank is leaking| Check the tank.
There is a partial blockage| Clear the blockage
Pressure switch is defective| Replace the pressure switch
Macerator is not emitting a humming noise.| The unit is not properly connected to the electric supply| Check the supply
| The pressure switch is not connected.| Check by pressing the override switch several times.
| The motor is not operational| If pressing the override switchhas no effect the motor may be dead.