Rion Technology MCA416T Digital Output Type Inclinometer Instruction Manual
- June 12, 2024
- Rion Technology
Table of Contents
Rion Technology MCA416T Digital Output Type Inclinometer
PRODUCT DEBUGGING SOFTWARE
DATA FRAME FORMAT:(8 bits date, 1 bit stop, No check, Default baud rate 9600
- Date format:hexadecima
- Identifier: Fixed68H,
- Data length: From data length to check sum(including check sum) length,
- Address code:acquisition module address
- Default :00
- Data field will vary with content and length of command word
- Check sum:sum of Data length,Address code,Command word and data field, not include identifier.
COMMAND WORD ANALYSIS
DESCRIPTION
- MCA416/426T seriesinclinationsensorisanewlow-costfull attitude tilt angle measurement product independently developed by RION. Adopting the latest anti-interference platform design, integrating new micro-mechanical sensing unit, wide temperature working performance, excellent anti- vibration performance, stable and reliable long-term work,and effective working life of upto 10years.
- This product uses a non-contact principle to measure the tilt angle of an object, and calculates the real-time tilt angle by measuring the component produced by the earth’s gravity through an internal capacitive micromechanical unit. The installation is simple and convenient, and it only needs to be fixed on the object to be tested, and does not need to fix the shaft and the rotating shaft.A variety of installation methods to meet customer measurement needs. It is an ideal accessory for engineering machinery, agricultural machinery, and other industrial equipment.
FEATURES
- Resolution:0.1°
- Six installation methods
- Zero set function
- IP67
- Output: RS232/RS485/TTL
- Power supply: 9~36V
- Work temperature:-40~+85°C
- High anti-O shock>3500g
SYSTEM DIAGRAM
SIZE
USAGE
- The working principle is sensing gravity of earth, when installation, the sensing axis of the sensor should be parallel with the tilt axis of measured object to achieve the best accuracy. the install surface of the measured object must be flat, stable, contact lose, error may be caused if the installation surface is noteven.
- Any side of the six sides of the sensor could be as the installation side. After installation, set current position as zero position by the zero set function, (at the same time, the installation way is set as well, the set value is stored in reservoir of the sensor. After zero set, the sensor will work and regard the current position as zero position). set steps as below: short circuit set line(grey) and GND(black) for 3 second above, the power indicator will shut off at the same time, unbind set line after power indicator flicker again, zero set finished, indicator will back to normally on status.
- The protection class is Ip66, rain or water spray would not affect its proper work, please do not soak it under water for long time in case inner circuit would be damaged, damage caused by which is beyond warranty service
- After installation, please do not short-circuit signal wire and power+ in case of damaging output circuit. the signal- and power- is shared by the same wire, so please connect acquisition signal- end to the power-.
APPLICATION
- Agricultural machinery
- Lifting machinery
- Crane
- Aerial platform
- Solar tracking system
- Medical equipment
- Electric vehicle control
PARAMETERS
ORDER GUIDE
E.g: MCA416T-LU-10: Indicates Single-axis, Horizontal Up Installation Method, +10° Measure range.
CONNECTION
- Cable diameter : 05.5mm
- Single core diameter : 01.3mm
INSTALLATION WAY
-
HORIZONTAL MEASUREMENT INSTALLATION DIRECTION
-
VERTICAL MEASUREMENT INSTALLATION DIRECTION
Remarks: The factory default installation is horizontal upward, the user can sets the corresponding installation method according to needs, please refer to Article 2 of the operating instructions, and make the corresponding settings.
Add:Block 1, COFCO(FUAN) Robotics Industrial Park , Da Yang Road No. 90,
Fuyong District, Shenzhen City, China
Tel:(86) 755-29657137 (86) 755-29761269
Fax:(86) 755-29123494