STARWELL NW-200-12 200W Switching Power Supply Instruction Manual

June 12, 2024
Starwell

STARWELL NW-200-12 200W Switching Power Supply

STARWELL-NW-200-12-200W-Switching-Power-Supply-product

Product Information

Dimension:

  • Length: 200 mm
  • Width: 110 mm
  • Height: 50 mm

Weight: 0.49 Kg

Applications

  • Industrial control system
  • Industrial automation machinery
  • Mechanical and electrical equipment
  • Electronic instruments, equipment or apparatus
  • LED Lighting Series

Features

  • International broad voltage AC input
  • Protection against short-circuit, overload, and overheat
  • 100% full-load aged 300VAC surge withstandable for 5 seconds
  • Working temperature up to 60°C
  • 5G vibration tested
  • High efficiency, long lifespan, and high reliability
  • 2 years warranty

Specifications

Product No. NW-200-12 NW-200-15 NW-200-24 NW-200-48
DC voltage 12V 15V 24V 48V
Rated Current 16.5A 13.3A 8.3A 4.2A
Current Range 0-16.5A 0-13.3A 0-8.3A 0-4.2A
Output Rated Power 200W 200W 200W 200W
Ripple and Noise (Max) 150mVp-p 180mVp-p 240mVp-p 250mVp-p
Voltage adjustment 10.8-13.2V 13.5-16.5V 22-27.6V 44-52V
Voltage Accuracy Note3
Linear Adjustment Note4
Load Adjustment Note5
Start and rise time 1000ms, 30ms/230VAC 1000ms, 30ms/110V
Hold timeTyp 50ms/230VAC 10ms/115AC
Voltage range
Frequency range 50HZ/60HZ
Input EfficiencyTyp AC current Typ Surge current (Typ) 80% 81% 82% 85%
Cold Start 65A/230VAC
Current leak

Product Usage Instructions

1. Ensure the input voltage matches the international broad voltage AC input range.

2. Connect the product to the appropriate industrial control system, industrial automation machinery, mechanical and electrical equipment, electronic instruments, equipment or apparatus, or LED lighting series.

3. Make sure the protection features are enabled to prevent short-circuits, overloads, and overheating.

4. If necessary, adjust the output voltage within the specified voltage adjustment range.

5. Check the ripple and noise levels to ensure they are within the specified limits.

6. Follow the specified start and rise time for proper power supply operation.

7. Check the hold time to ensure the power supply can maintain a stable output during power interruptions.

8. Follow the specified input efficiency and AC currentrequirements for optimal performance.

9. If applicable, perform a cold start according to the specified procedure.

10. Make sure there are no current leaks from the power supply.

11. For any issues or defects, refer to the 2 years warranty for support and assistance.

Applications

  • Industrial controlsystem
  • Industrial automation machinery
  • Mechanical and electrical equirment
  • Electronic instruments, equirments or apparatus
  • LED Lighting Series

Features

  • International broad voltage AC input
  • Protection: short‐circuit, overload,overheat
  • 100% full‐load aged
  • 300VAC surge for 5 seconds withstandable
  • Working temperature up to 60℃
  • 5G vibration tested
  • High efficiency, long life span, and high reliability
  • 2 years warranty

Dimension

  • L: 200 mm
  • W: 110 mm
  • H: 50mm
  • Weight: 0.49Kg

Specifications

Product No.| NW‐200‐12| NW‐200‐15| NW‐200‐24| NW‐200‐48| |
---|---|---|---|---|---|---

Output

| DC voltage| 12V| 15V| 24V| 48V|  |
Rated Current| 16.5A| 13.3A| 8.3A| 4.2A|  |
Current Range| 0‐16.5A| 0‐1.3A| 0‐8.3A| 0‐4.2A|  |
Rated Power| 200W| 200W| 200W| 200W|  |
Ripple and Noise(Max)Note.2| 150mVp‐p| 180mVp‐p| 240mVp‐p| 250mVp‐p|  |
Voltage adjustment| 10.8‐13.2V| 13.5‐16.5V| 22‐27.6V| 44‐52V|  |
Voltage Accuracy Note3| ±1%| ±1%| ±1%| ±1%|  |
Linear Adjustment Note4| ±0.5%| ±0.5%| ±0.5%| ±0.5%|  |
Load Adjustment Note5| ±0.5%| ±0.5%| ±0.5%| ±0.5%|  |
Start and rise time| 1000ms,30ms/230VAC 1000ms,30ms/110V
Hold time(Typ)| 50ms/230VAC 10ms/115AC

Input

| Voltage range| AC 110V±15%/AC 220±15% changed by switch
Frequency range| 50HZ/60HZ
Efficiency(Typ)| 80%| 81%| 82%| 85%|  |
AC current (Typ)| 4.17A/110V 1.9A/220V
Surge current (Typ)| Cold Start:65A/230VAC
Current leak| <2mA/240VAC
Protection| Overload| Larger than 105% of capacity
restoration after abnormity removed

Environment

| Working temp.| ‐20~+60℃(Refer to the tenuation curve)
Working humidity| 20~90% RH, without condense
Storage temp & hmdty| ‐40~+80℃
Temp. coefficient| ±0.03%/℃ (0~50℃)
Vibration proof| 10 ~500HZ,5G 10min / cycle X Y Z axes 60 min each

Safety reg. & EMC (Note.6)

| Safety regulation| GB195110.1‐2004/IEC61347‐1:2003 CE(EMC+LVD)
Voltage proof| I/P‐O:1.5KVAC I/P‐FG:1.5KVAC O/P‐FG:0.5KVAC
insulation resistance| I/P‐O/P, I/P‐FG,O/P‐FG:100M Ohms/500VDC/25℃/70% RH
EMC irradiation| EN 55032:2015+A11:2020;EN55035:2017+A11:2020
EMC disturbance proof| EN IEC 61000‐3‐2:2019; EN 61000‐3‐3:2013+A1:2019
 | Dimensions| 20011050mm(LWH)
Packing| 0.49kg/PCS;24PCS/18.2kg

Notes:

| 1.  Unless specially indicated, all data are taken under 230VAC input, rated load and 25℃ environment temp.

2.Ripple and noise: measured with a 12” double ripple cord connected in parallel with a 0.1μF and a 47 μF capacitor on 20MHz bandwidth.

3.Accuracy: including preset errors, linear adjustment rate and load adjustment rate. 4.Linear adjustment: taken under rated load from low voltage to high voltage.

5. Load adjustment: taken under 0~100% of rated load.

6.  Power supply is taken as part of the whole system, and needs to be confirmed with terminal instruments for EMC.

Appearance

STARWELL-NW-200-12-200W-Switching-Power-Supply-fig
1

Frame diagram

STARWELL-NW-200-12-200W-Switching-Power-Supply-fig
2

Tenuation curve

Static property curve

Documents / Resources

| STARWELL NW-200-12 200W Switching Power Supply [pdf] Instruction Manual
NW-200-12, NW-200-15, NW-200-24, NW-200-48, NW-200-12 200W Switching Power Supply, 200W Switching Power Supply, Switching Power Supply, Power Supply, Supply
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Starwell User Manuals

Related Manuals