STARWELL NW-200-12 200W Switching Power Supply Instruction Manual
- June 12, 2024
- Starwell
Table of Contents
STARWELL NW-200-12 200W Switching Power Supply
Product Information
Dimension:
- Length: 200 mm
- Width: 110 mm
- Height: 50 mm
Weight: 0.49 Kg
Applications
- Industrial control system
- Industrial automation machinery
- Mechanical and electrical equipment
- Electronic instruments, equipment or apparatus
- LED Lighting Series
Features
- International broad voltage AC input
- Protection against short-circuit, overload, and overheat
- 100% full-load aged 300VAC surge withstandable for 5 seconds
- Working temperature up to 60°C
- 5G vibration tested
- High efficiency, long lifespan, and high reliability
- 2 years warranty
Specifications
Product No. | NW-200-12 | NW-200-15 | NW-200-24 | NW-200-48 |
---|---|---|---|---|
DC voltage | 12V | 15V | 24V | 48V |
Rated Current | 16.5A | 13.3A | 8.3A | 4.2A |
Current Range | 0-16.5A | 0-13.3A | 0-8.3A | 0-4.2A |
Output Rated Power | 200W | 200W | 200W | 200W |
Ripple and Noise (Max) | 150mVp-p | 180mVp-p | 240mVp-p | 250mVp-p |
Voltage adjustment | 10.8-13.2V | 13.5-16.5V | 22-27.6V | 44-52V |
Voltage Accuracy | Note3 | – | – | – |
Linear Adjustment | Note4 | – | – | – |
Load Adjustment | Note5 | – | – | – |
Start and rise time | 1000ms, 30ms/230VAC | 1000ms, 30ms/110V | – | – |
Hold timeTyp | 50ms/230VAC | 10ms/115AC | – | – |
Voltage range | – | – | – | – |
Frequency range | 50HZ/60HZ | – | – | – |
Input EfficiencyTyp AC current Typ Surge current (Typ) | 80% | 81% | 82% | 85% |
Cold Start | 65A/230VAC | – | – | – |
Current leak | – | – | – | – |
Product Usage Instructions
1. Ensure the input voltage matches the international broad voltage AC input range.
2. Connect the product to the appropriate industrial control system, industrial automation machinery, mechanical and electrical equipment, electronic instruments, equipment or apparatus, or LED lighting series.
3. Make sure the protection features are enabled to prevent short-circuits, overloads, and overheating.
4. If necessary, adjust the output voltage within the specified voltage adjustment range.
5. Check the ripple and noise levels to ensure they are within the specified limits.
6. Follow the specified start and rise time for proper power supply operation.
7. Check the hold time to ensure the power supply can maintain a stable output during power interruptions.
8. Follow the specified input efficiency and AC currentrequirements for optimal performance.
9. If applicable, perform a cold start according to the specified procedure.
10. Make sure there are no current leaks from the power supply.
11. For any issues or defects, refer to the 2 years warranty for support and assistance.
Applications
- Industrial controlsystem
- Industrial automation machinery
- Mechanical and electrical equirment
- Electronic instruments, equirments or apparatus
- LED Lighting Series
Features
- International broad voltage AC input
- Protection: short‐circuit, overload,overheat
- 100% full‐load aged
- 300VAC surge for 5 seconds withstandable
- Working temperature up to 60℃
- 5G vibration tested
- High efficiency, long life span, and high reliability
- 2 years warranty
Dimension
- L: 200 mm
- W: 110 mm
- H: 50mm
- Weight: 0.49Kg
Specifications
Product No.| NW‐200‐12| NW‐200‐15| NW‐200‐24| NW‐200‐48|
|
---|---|---|---|---|---|---
Output
| DC voltage| 12V| 15V| 24V| 48V| |
Rated Current| 16.5A| 13.3A| 8.3A| 4.2A| |
Current Range| 0‐16.5A| 0‐1.3A| 0‐8.3A| 0‐4.2A| |
Rated Power| 200W| 200W| 200W| 200W| |
Ripple and Noise(Max)Note.2| 150mVp‐p| 180mVp‐p| 240mVp‐p| 250mVp‐p| |
Voltage adjustment| 10.8‐13.2V| 13.5‐16.5V| 22‐27.6V| 44‐52V| |
Voltage Accuracy Note3| ±1%| ±1%| ±1%| ±1%| |
Linear Adjustment Note4| ±0.5%| ±0.5%| ±0.5%| ±0.5%| |
Load Adjustment Note5| ±0.5%| ±0.5%| ±0.5%| ±0.5%| |
Start and rise time| 1000ms,30ms/230VAC 1000ms,30ms/110V
Hold time(Typ)| 50ms/230VAC 10ms/115AC
Input
| Voltage range| AC 110V±15%/AC 220±15% changed by switch
Frequency range| 50HZ/60HZ
Efficiency(Typ)| 80%| 81%| 82%| 85%| |
AC current (Typ)| 4.17A/110V 1.9A/220V
Surge current (Typ)| Cold Start:65A/230VAC
Current leak| <2mA/240VAC
Protection| Overload| Larger than 105% of capacity
restoration after abnormity removed
Environment
| Working temp.| ‐20~+60℃(Refer to the tenuation curve)
Working humidity| 20~90% RH, without condense
Storage temp & hmdty| ‐40~+80℃
Temp. coefficient| ±0.03%/℃ (0~50℃)
Vibration proof| 10 ~500HZ,5G 10min / cycle , X 、
Y 、 Z axes 60 min each
Safety reg. & EMC (Note.6)
| Safety regulation| GB195110.1‐2004/IEC61347‐1:2003 CE(EMC+LVD)
Voltage proof| I/P‐O:1.5KVAC I/P‐FG:1.5KVAC O/P‐FG:0.5KVAC
insulation resistance| I/P‐O/P, I/P‐FG,O/P‐FG:100M Ohms/500VDC/25℃/70% RH
EMC irradiation| EN 55032:2015+A11:2020;EN55035:2017+A11:2020
EMC disturbance proof| EN IEC 61000‐3‐2:2019; EN 61000‐3‐3:2013+A1:2019
| Dimensions| 20011050mm(LWH)
Packing| 0.49kg/PCS;24PCS/18.2kg
Notes:
| 1. Unless specially indicated, all data are taken under 230VAC input, rated load and 25℃ environment temp.
2.Ripple and noise: measured with a 12” double ripple cord connected in parallel with a 0.1μF and a 47 μF capacitor on 20MHz bandwidth.
3.Accuracy: including preset errors, linear adjustment rate and load adjustment rate. 4.Linear adjustment: taken under rated load from low voltage to high voltage.
5. Load adjustment: taken under 0~100% of rated load.
6. Power supply is taken as part of the whole system, and needs to be confirmed with terminal instruments for EMC.
Appearance
Frame diagram
Tenuation curve
Static property curve
Documents / Resources
|
STARWELL NW-200-12 200W Switching Power
Supply
[pdf] Instruction Manual
NW-200-12, NW-200-15, NW-200-24, NW-200-48, NW-200-12 200W Switching Power
Supply, 200W Switching Power Supply, Switching Power Supply, Power Supply,
Supply
---|---