EPH CONTROLS PR092K7 RF Cylinder Thermostat Instruction Manual
- June 12, 2024
- EPH CONTROLS
Table of Contents
EPH CONTROLS PR092K7 RF Cylinder Thermostat
Product Information
The RFC – RF Cylinder Thermostat is a wireless enabled thermostat designed for controlling the temperature of a cylinder. It comes with various features and functions to ensure accurate temperature control and ease of use.
Factory Default Settings
- Temperature indicator: Off
- Switching differential: Not specified
- In-built frost protection: Not specified
- Keypad lock: Off
Specifications
- Power Supply: Not specified
- Power consumption: Not specified
- Battery replacement: Required (batteries provided)
- Temp. Control Range: Not specified
- Dimensions: Not specified
- Temp. sensor: Not specified
- Temp. indication: Not specified
Button / Symbol Description
-
Wireless symbol: Indicates wireless connectivity
-
Heating ON symbol: Indicates that the heating is turned on
-
Water temperature: Indicates the current water temperature
-
Battery low symbol: Indicates low battery level
-
Boost button: Used for activating the boost function
-
Set point handwheel: Used for setting the desired
temperature -
Code button: Not specified
-
Reset button: Used for resetting the thermostat
Product Usage Instructions
Prior Setup
Before setting up the thermostat, ensure that all required settings are completed as described in the user manual.
CAUTION: Only qualified electricians or authorized service staff are permitted to open the thermostat.
Ensure that the wireless enabled thermostat is installed at least 1 meter away from any metallic object, television, radio, or wireless internet transmitter.
Mounting
The thermostat can be mounted in various ways:
- Recessed conduit boxes
- Surface mounting boxes
- Directly on walls
Installation
- Press the button on the bottom of the thermostat to detach the front housing from the baseplate.
- Insert the provided batteries into the thermostat.
- Press the reset button on the PCB to initiate the reset process.
- Rotate the hand wheel clockwise until ‘YES’ appears on the screen.
- Press the hand wheel once to confirm the setting.
- The thermostat has now been reset, and the current temperature will appear on the screen.
Boost Function
To boost the heating for a specific duration:
- Press the boost button once, twice, or three times to boost the heating for 1, 2, or 3 hours respectively.
- ‘+1H’, ‘+2H’, or ‘+3H’ will appear on the screen to indicate the boost duration.
- The boost function will override the programmer if it is timed to be Off.
Lock Function
To lock the thermostat:
- Press the hand wheel for 10 seconds.
- The keypad symbol will appear on the screen, indicating that the thermostat is locked.
To unlock the thermostat:
- Press the hand wheel for 10 seconds.
- The keypad symbol will disappear from the screen, indicating that the thermostat is unlocked.
For further assistance, please contact EPH Controls Ireland at technical@ephcontrols.com or visit their website at www.ephcontrols.com. For inquiries in the UK, contact EPH Controls UK at technical@ephcontrols.com or visit their website at www.ephcontrols.co.uk.
Factory default settings
- Temperature indicator: °C
- Switching differential: 5°C
- In built frost protection: 5°C
- Keypad lock: Off
Specifications & wiring
- Power Supply: 2 x AAA Alkaline Battery
- Power consumption: 50 uA
- Battery replacement: Once per year
- Temp. Control Range: 10…90°C
- Dimensions: 84 84 30mm
- Temp. sensor: NTC 10K Ohm @ 25°C – 1.5m probe type
- Temp. indication: °C
Mounting
Mounting of temperature sensor
ON CYLINDER: To ensure accurate control of your cylinder, the temperature
sensor should be mounted on the bottom 1/3 of the cylinder. It is essential
that the sensing element is in direct contact with the cylinder and that there
is no insulation between it and the cylinder. 60°C is the temperature level
required in order to prevent the build up of legionella bacteria. The
temperature sensor can be fixed to the cylinder using the provided foil tape.
ON PIPEWORK: To ensure accurate control, the temperature sensor should be
mounted on the pipework as tightly as possible. It is essential that the
sensing element is in direct contact with the pipework and that there is no
insulation between it and the pipework. The temperature sensor can be fixed to
the pipework using the provided foil tape.
Mounting of thermostat
The thermostat should be mounted in a position that will make reading the display conventient.
The thermostat can be fitted to:
- Recessed conduit boxes
- Surface mounting boxes
- Directly on walls
Installation
- Press the button on the bottom of the thermostat.
- The front housing will detach from the baseplate.
- Insert the batteries (provided) into the thermostat.
- Mount the unit as described in section 3. Ensure the cable sensor is connected to terminals Con 3 and Con 4.
- Offer the baseplate up to the thermostat. Snap it into position to close.
CAUTION!
Only qualified electricians or authorised service staff are permitted to open
the thermostat.
Ensure that this wireless enabled thermostat is installed 1 metre from any
metalic object, television, radio or wireless internet transmitter.
Button / symbol description
Resetting the thermostat
- Press the button on the bottom of the thermostat, the front housing will detach from the baseplate.
- Insert the batteries into the thermostat.
- Press the reset button on the PCB, ‘NO’ will flash on the screen.
- Rotate the hand wheel clockwise until ‘YES’ appears on the screen.
- Press the hand wheel once to confirm the setting.
- The thermostat has now been reset and the current temperature will appear on the screen.
Function
Boost function
- Press the boost button once, twice or three times to boost the heating for 1, 2 or 3 hours respectively. +1H, +2H or +3H will appear on the screen.
- The boost function will override the programmer if the programmer is timed to be OFF.
Lock function
- To lock the thermostat, press the hand wheel for 10 seconds. The keypad symbol will appear on the screen.
- To unlock the thermostat, press the hand wheel for 10 seconds. The keypad symbol will disappear from the screen.
To connect the RF thermostat with the programmer
- Lower the cover on the front of the timeswitch /programmer. Move the selector switch to the RUN position.
- On the timeswitch / programmer, press the button for 5 seconds.
- Wireless Connect will appear on the screen.
- On the RFR wireless room thermostat or RFC wireless cylinder thermostat, press the Code button. This is located inside the housing on the Printed Circuit Board.
- On the timeswitch / programmer, the available zones will begin to Flash.
- Press the button for the zone you wish to connect the thermostat to.
- The wireless symbol appears on the screen.
- The thermostat will count to 3 and then display the zone of the programmer that it is paired to.
- If it is paired to the first zone it will display r1, the second zone r2 etc.
- Press the wheel on the thermostat to complete the pairing process.
- The timeswitch / programmer is now operating in the wireless mode.
- The temperature of the wireless thermostat is now displayed on the programmer. Repeat this process for the second, third and fourth zone if required.
To disconnect the RF thermostat with the programmer
- Lower the cover on the front of the timeswitch /programmer. Move the selector switch to the RUN position.
- On the timeswtich/ programmer, press the button for 5 seconds.
- This will take you into the Wireless Connect screen.
- Press the button for 3 seconds.
- This will clear all RF connections thereby disconnecting all thermostats from the timeswitch / programmer.
- Press the button.